Back to Authors

Legried, Michele

Mayo Clinic

Mayo Clinic

Citations 2

Comparison of blood culture contamination rates with standard practice versus two blood diversion devices at a single institution
Vieni, Casey , Legried, Michele, Mainella, Jill, Bute, Kelly, Backus, Linda, Sampathkumar, Priya , Schuetz, Audrey N. , Patel, Robin , Karon, Brad S. , Patel, Robin , Schuetz, Audrey N , Mainella, Jill M.

Journal of Clinical Microbiology | June 29, 2026 | Volume: 64 | Issue: 8 | Pages: No page available

10.1128/jcm.00085-26 Get It

ABSTRACT Blood culture contamination can lead to false-positive blood culture results, potentially contributing to increased costs and unneeded antibiotic utilization. Initial specimen diversion devices (ISDD) have been proposed to reduce blood culture contamination rates. A single-center, observational study conducted at Mayo Clinic Rochester compared blood culture contamination rates using Steripath or Kurin ISDDs versus standard blood culture collection protocols. Over 255 phlebotomists were trained in the use of the ISDDs, with 31,215 blood cultures, 410 of which were contaminated, collected from adults in the emergency department and inpatient wards. Baseline contamination rates were 1.29%–2.53% with standard collection methods. The Steripath ISDD with direct-to-media inoculation of blood culture bottles (Steripath-DTM) reduced blood culture contamination compared to standard practice (0.34% vs. 1.43%, respectively, P < 0.001). Follow-up studies with the alternative Steripath configuration with an integrated syringe (Steripath-syringe), and then the Kurin ISDD with syringe collection (Kurin-syringe), did not meet the primary endpoint of <0.5% contamination (Steripath-syringe: 1.28%; Kurin-syringe: 1.76%). All three ISDD configurations failed to meet our goal of >75% utilization, with an average measured utilization of 26% for the Steripath-DTM, 26.4% for the Steripath ISDD (combined DTM and syringe) in a follow-up study, and 41.5% in the Kurin study. Additionally, a survey of phlebotomists revealed low staff satisfaction with both Steripath ISDD configurations. Staff reported multiple ergonomic barriers limiting the Steripath ISDD’s utility, which precluded implementation of the Steripath-DTM in routine clinical practice. IMPORTANCE We conducted a very large, real-world study of two blood diversion devices to determine whether either would meet goals for reduced blood culture contamination and a high rate of utilization by phlebotomists.
Keep calm and invert on: Reducing blood recollection rates in the neonatal intensive care unit (NICU)
Ramos, Paola , Streeton, Abigail, Lunde, Julie, Legried, Michele, Karon, Bradley, Baumann, N

American Journal of Clinical Pathology | November 9, 2022 | Volume: 158 | Issue: Supplement_1 | Pages: S7-S8

10.1093/ajcp/aqac126.012 Get It

Abstract Background Minimizing blood specimen recollection due to specimen integrity issues is a continuous quality improvement goal in the neonatal intensive care unit (NICU). Specimen integrity issues, such as clotting or hemolysis, are often the result of improper specimen collection processes and lead to blood loss requiring transfusion, additional painful procedures, and delays in patient care. Data collected from Mayo Clinic Hospital - Methodist Campus NICU at Mayo Clinic in Rochester, MN between January – July 2019 showed that clotted complete blood count (CBC) specimens accounted for one-third of rejected neonatal specimens followed by hemolyzed specimens for direct bilirubin (DBIL) testing. The aim of this project was to reduce the percent of CBC and DBIL tests canceled/specimens rejected due to specimen integrity issues in the NICU from 17% to 10% using the Plan-Do-Study-Act methodology. Methods A multidisciplinary quality improvement (QI) team was formed, inclusive of both NICU and laboratory representatives. Bedside direct observations (n=28) were performed by NICU nurses to help identify inconsistencies in the blood collection processes. A total of three Plan-Do-Study-Act (PDSA) cycles were conducted during the 2020-2021 time period. An assessment card was created and revised with each PDSA cycle. The card was completed by the nurse(s) present during the blood collection and initially identified the lab tests ordered, collection tubes, collection type (venipuncture, venous, capillary), number of tube inversions required, staff present during collection, any delays during collection, and whether the draw was deemed successful. Additionally, staff education videos for nursing and laboratory phlebotomy staff were created to demonstrate correct collection tube inversion technique. Results Direct observation identified inconsistent practices in tube inversion during specimen collection. The first PDSA cycle (n=207 collections, April 1 – July 13, 2021) introduced a verbal inversion count and utilization of the assessment card. The following cycle (n=336 collections, July 14 – October 10, 2021) implemented an educational video and modified the assessment card to include start and end time of the draw. The third cycle (n=243 collections, October 11 – November 30, 2021) used a simplified assessment card including patient label, tests ordered, tube type and inversions. The combined rejection rates for CBC and DBIL tests were 4.3%, 3.8% and 2.8% for the 1st, 2nd and 3rd PDSA cycles, respectively. Conclusions Our QI initiative reduced the specimen rejection rate for clotted CBC and hemolyzed DBIL specimens from 17% to 2.8% in the NICU. Interventions focused on improving tube inversion techniques and promoting collaborative relationships between phlebotomists and nursing staff. The use of educational videos and completion of assessment cards during collections were effective at reducing specimen rejection rates.