Back to Authors

Balasubramanyam, Aarthi

Mayo Clinic

MyoKardia (United States)

Citations 2

Abstract 13567: Impact of Mavacamten on Artificial Intelligence Electrocardiographic Diagnosis of Hypertrophic Cardiomyopathy in the EXPLORER-HCM Trial
Siontis, Konstantinos C. , Abreau, Sean , Abraham, Theodore P. , Oręziak, Artur , Masri, Ahmad , Lakdawala, Neal K. , Agarwal, Priyanka, Balasubramanyam, Aarthi, Sehnert, Amy J. , Friedman, Paul A. , Olgin, Jeff E, Barrios, Joshua P. , Attia, Zachi I. , Olivotto, Iacopo , Villa, Roberto Barriales , Olgin, Jeff E, Noseworthy, Peter A. , Tison, Geoffrey H.

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.13567 Get It

Introduction: Deep-learning artificial intelligence (AI) algorithms can identify hypertrophic cardiomyopathy (HCM) from the electrocardiogram (ECG). Preliminary data indicate that AI-ECG may also track treatment response in HCM patients (pts) receiving mavacamten (Mava). In this placebo-controlled analysis, we investigated the performance of AI-ECG in HCM detection and its changes during Mava treatment compared to placebo in the phase 3, EXPLORER-HCM trial. Methods: Pts with non-paced ECGs enrolled in EXPLORER-HCM, evaluating Mava over 30 weeks of treatment, were included. All pts had a 12-lead ECG pre-treatment, at each study visit, and 8 weeks after treatment end. Two independently developed AI-ECG convolutional neural network algorithms from the Mayo Clinic and the University of California, San Francisco (UCSF) were applied to all ECGs suitable for analysis. Serial AI-ECG-predicted scores, which correlate with HCM likelihood (range 0-1), were examined between Mava and placebo groups. Results: A total of 101 Mava and 110 placebo pts were included (mean age 58.6, female 40%). At baseline, the mean Mayo and UCSF AI-ECG scores for HCM were 0.82 and 0.65, with 94% and 88% of pts exceeding the respective diagnostic thresholds of 0.11 (Mayo) and 0.4 (UCSF). During 30 weeks of follow-up in the Mava group, the algorithms showed a mean AI-ECG score reduction of 0.32 (Mayo) and 0.17 (UCSF) in all pts between start and end of treatment. In comparison, AI-ECG scores decreased by 0.05 (Mayo) and increased by 0.02 (UCSF) in the placebo group (Mava vs placebo, t-test p-values <0.001 for both algorithms; Figure ) Conclusion: In the EXPLORER-HCM trial population, two independent deep-learning AI-ECG algorithms correctly identified most HCM pts and demonstrated significant reductions in predicted HCM scores after treatment with Mava when compared to placebo. This relative normalization of the ECG suggests disease-modifying properties of Mava, deserving further investigation.
Dose-Blinded Myosin Inhibition in Patients With Obstructive Hypertrophic Cardiomyopathy Referred for Septal Reduction Therapy: Outcomes Through 32 Weeks
Desai, Milind Y. , Owens, Anjali , Geske, Jeffrey B. , Wolski, Kathy , Saberi, Sara , Wang, Andrew , Cremer, Paul , Naidu, Srihari S. , Smedira, Nicholas G. , McErlean, Ellen, Sewell, Christina , Balasubramanyam, Aarthi, Lampl, Kathy, Sehnert, Amy J. , Nissen, Steven E. , Sherrid, Mark , Cremer, Paul C , Naidu, Srihari S , Smedira, Nicholas G , Schaff, Hartzell , Sewell, Christina , Sehnert, Amy J , Nissen, Steven E , Geske, Jeffrey B , Saberi, Sara , Wang, Andrew , Sherrid, Mark V. , Schaff, Hartzell V.

Circulation | November 6, 2022 | Volume: 147 | Issue: 11 | Pages: 850-863

10.1161/circulationaha.122.062534 Get It

Background: Septal reduction therapy (SRT) in patients with intractable symptoms from obstructive hypertrophic cardiomyopathy (oHCM) is associated with variable morbidity and mortality. The VALOR-HCM trial (A Study to Evaluate Mavacamten in Adults with Symptomatic Obstructive Hypertrophic Cardiomyopathy Who Are Eligible for Septal Reduction Therapy) examined the effect of mavacamten on the need for SRT through week 32 in oHCM. Methods: A double-blind randomized placebo-controlled multicenter trial at 19 US sites included patients with oHCM on maximal tolerated medical therapy referred for SRT with left ventricular outflow tract gradient ≥50 mm Hg at rest or provocation (enrollment, July 2020–October 2021). The group initially randomized to mavacamten continued the drug for 32 weeks, and the placebo group crossed over to dose-blinded mavacamten from week 16 to week 32. Dose titrations were based on investigator-blinded echocardiographic assessment of left ventricular outflow tract gradient and left ventricular ejection fraction. The principal end point was the proportion of patients proceeding with SRT or remaining guideline eligible at 32 weeks in both treatment groups. Results: From the 112 randomized patients with oHCM, 108 (mean age, 60.3 years; 50% men; 94% in New York Heart Association class III/IV) qualified for week 32 evaluation (56 in the original mavacamten group and 52 in the placebo cross-over group). After 32 weeks, 6 of 56 patients (10.7%) in the original mavacamten group and 7 of 52 patients (13.5%) in the placebo cross-over group met SRT guideline criteria or elected to undergo SRT. After 32 weeks, a sustained reduction in resting left ventricular outflow tract gradient (−33.0 mm Hg [95% CI, −41.1 to −24.9]) and Valsalva left ventricular outflow tract gradient (−43.0 mm Hg [95% CI, −52.1 to −33.9]) was observed in the original mavacamten group. A similar reduction in resting (−33.7 mm Hg [95% CI, −42.2 to −25.2]) and Valsalva (−52.9 mm Hg [95% CI, −63.2 to −42.6]) gradients was quantified in the cross-over group after 16 weeks of mavacamten. After 32 weeks, improvement by ≥1 New York Heart Association class was observed in 48 of 53 patients (90.6%) in the original mavacamten group and 35 of 50 patients (70%) after 16 weeks in the cross-over group. Conclusions: In severely symptomatic patients with oHCM, 32 weeks of mavacamten treatment showed sustained reduction in the proportion proceeding to SRT or remaining guideline eligible, with similar effects observed in patients who crossed over from placebo after 16 weeks. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04349072.