Back to Authors

Tostrud, Linda J.

Mayo Clinic

Mayo Clinic

Citations 3

Quantitative Alterations in Complement Alternative Pathway and Related Genetic Analysis in Severe Phenotype Preeclampsia
Alrahmani, Layan , Cousin, Margot A. , Moyer, Ann M. , Willrich, Maria Alice V. , Wick, Myra , Tostrud, Linda J., White, Wendy M, Narang, Kavita , Alrahmani, Layan , Willrich, Maria A , Suarez, Maria Lourdes Gonzalez , White, Wendy , Garovic, Vesna D.

Kidney360 | June 30, 2021 | Volume: 2 | Issue: 9 | Pages: 1463-1472

10.34067/kid.0000992021 Get It

Key Points Women with severe preeclampsia demonstrate abnormal levels of the complement alternative pathway components. Genetic variants in the complement alternative pathway are more prevalent in those with severe phenotype preeclampsia compared with the general population. Future studies should explore the role of medications that block the complement alternative pathway in treatment of preeclampsia. Background Preeclampsia and hemolysis, elevated liver enzymes, and low platelets (HELLP) syndrome share many clinical and biologic features with thrombotic microangiopathy syndromes caused by complement abnormalities. Our hypothesis was that similar functional and genetic alterations in the complement alternative pathway (CAP) are present in these disorders of pregnancy. Methods We conducted quantitative analysis of proteins involved in CAP using ELISA and nephelometry on prospectively collected blood samples from patients with severe phenotype preeclampsia (defined as delivery ≤34 weeks due to preeclampsia), HELLP syndrome, or eclampsia, and matched normotensive controls ( n =25 in each arm) between 2011 and 2016. Sequencing was performed to interrogate 14 genes encoding CAP components. Results Both groups were similar in age, gravidity, parity, marital status, and race. The study group had a higher BMI (mean±SD, 32±8 versus 25±4 kg/m 2 ; P =0.002) and earlier gestational age at delivery (32.5±3.6 versus 40.3±1 weeks; P <0.001). Serologic studies demonstrated elevated Bb subunit (median [range], 1.2 [0.5–4.3] versus 0.6 [0.5–1] μ g/ml; P<0.001), complement C5 concentration (28 [18–33] versus 24 [15–34] mg/dl; P =0.03), and sMAC (371 [167–761] versus 184 [112–249] ng/ml; P<0.001) concentrations in patients with preeclampsia. Two thirds of patients with preeclampsia had at least one nonsynonymous sequence variant in CAP genes. Conclusion Patients with severe phenotype preeclampsia manifest functional alterations in CAP activation. Genetic variants in the CAP genes were detected in several patients, but a larger population study is necessary to fully evaluate genetic risk. Genetic screening and complement-targeted treatment may be useful in risk stratification and novel therapeutic approaches.
Simultaneous Phenotyping and Quantification of α-1-Antitrypsin by Liquid Chromatography–Tandem Mass Spectrometry
Snyder, Melissa R, Zhu, Yi , Tostrud, Linda J., Benson, Linda M., Katzmann, Jerry A., Bergen, H. Robert, Chen, Yuhong , Snyder, Melissa R, Zhu, Yi

Clinical Chemistry | June 3, 2011 | Volume: 57 | Issue: 8 | Pages: 1161-1168

10.1373/clinchem.2011.163006 Get It

BACKGROUNDα-1-Antitrypsin (A1AT) deficiency results from a genetic disorder at 2 common loci. Diagnosis requires quantification of A1AT and subsequent identification of the specific variant. The current algorithm of laboratory testing for the diagnosis of A1AT deficiency uses a combination of quantification (nephelometry), genotyping, and/or phenotyping. We developed a multiple reaction monitoring liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of A1AT and identification of the 2 most common deficiency alleles present in 95% of the patients with A1AT deficiency.METHODSSerum samples (n = 40) were digested with trypsin, and appropriate 13C/15N-labeled standard peptides were added. We performed LC-MS/MS analysis with a 0.5- by 150-mm C18 column and H2O:acetonitrile:n-propanol:formic acid (A:98:1:1:0.2 and B:10:80:10:0.2; flow 12 μL/min) mobile phase in positive ion mode on a TSQ Quantum triple quadrupole MS system. We measured the A1AT concentration by comparison to a calibration curve and determined the phenotype by the presence or absence of variant peptides. We compared the results to the current phenotyping assay by isoelectric focusing (IEF) and the immunonephelometry quantitative assay.RESULTSFor A1AT allele detection, in 39 of 40 samples the LC-MS/MS results were identical to those obtained by IEF gel electrophoresis. The single discrepant result was rerun by IEF at a lower dilution, and the results were in concordance. The A1AT quantification by LC-MS/MS also compared favorably with nephelometry.CONCLUSIONSThe LC-MS/MS method correlates well with current phenotyping and nephelometric assays and has the potential to improve the laboratory diagnosis of genetic A1AT deficiency.
Sharply Increased Serum Free Light-Chain Concentrations after Treatment for Multiple Myeloma
Murata, Kazunori , Clark, Raynell, Lockington, Karen S., Tostrud, Linda J., Greipp, Philip R., Katzmann, Jerry A.

Clinical Chemistry | December 29, 2009 | Volume: 56 | Issue: 1 | Pages: 16-18

10.1373/clinchem.2009.133041 Get It