Background: Retrospective cohort study of 561 adult patients undergoing secondary intraocular lens (IOL) implantation by vitreoretinal surgeons at a single institution from April 2015 to December 2020. Methods: Patient historical factors, intraoperative/postoperative complications, and outcomes of IOL type (anterior chamber IOL versus scleral sutured IOL versus scleral fixated IOL versus. sulcus) were assessed. Primary outcomes were rates of postoperative retinal tears and rhegmatogenous retinal detachment. Secondary outcomes were rates of intraoperative endolaser, intraoperative retinal tear, and further IOL surgery. Results: The incidence of intraoperative retinal tears was 7.3% and not significantly different between techniques. Rates of intraoperative endolaser use were 17.5% among all techniques and not significantly different between techniques. Rates of postoperative retinal tear were low (0%–2.7%). Rates of postoperative rhegmatogenous retinal detachment were not significantly different between techniques (anterior chamber IOL 9/198 [4.5%], SFIOL 1/54 [1.9%], scleral sutured IOL 14/274 [5.1%], sulcus 2/35 [5.7%], total 26/561 [4.6%], P = 0.79). Rates of repeat IOL surgery trended higher in sulcus lenses (anterior chamber IOL 5/198 [2.5%], SFIOL 4/54 [7.4%], scleral sutured IOL 16/274 [5.8%], sulcus 5/35 [14.3%], total 30/561 [5.3%], P = 0.12). Conclusion: Intraoperative endolaser use and intraoperative retinal tear are not uncommon in secondary IOL surgery and underscore the importance of careful vitreoretinal management among these patients.
Purpose: To evaluate the impact of anti–vascular endothelial growth factor therapy on the refractive error in eyes with diabetic macular edema. Methods: Post hoc analysis of Diabetic Retinopathy Clinical Research protocol T. Spherical equivalent (SE) was calculated for study and fellow eyes at baseline, 1-year, and 2-year visits. The SE change of the eyes with edema was compared with those with resolved edema. The correlation between refractive error changes and central subfield thickness was evaluated. Results: Among 543 study eyes, SE changed from −0.17 (2.04) D at baseline visit to −0.16 (2.14) D at 2 years giving a hyperopic shift of 0.04 (0.82) D (P = 0.022). Among fellow eyes, mean (SD) SE changed from −0.19 (2.1) D at baseline to −0.11 (2.1) D at 2 years, giving a hyperopic shift of 0.12 (0.84) D (P = 0.001). No significant difference in SE shift was found between eyes with and without edema at 2 years in phakic (0.12D and 0.08 D, P = 0.87) and pseudophakic eyes (−0.24D and −0.08D, P = 0.30). The SE shift was not correlated with central subfield thickness change at the end of the second year (r = 0.02, P = 0.62). Conclusion: Diabetic macular edema patients have minimal changes in refractive error. The correction of refractive error may be considered during treatment, regardless of the presence of edema.