Back to Authors

Park, Byung Kwan

https://orcid.org/0000-0002-4114-8859

Mayo Clinic

Samsung Medical Center

Citations 8

Diffusion-Tensor MRI at 3 T: Differentiation of Central Gland Prostate Cancer From Benign Prostatic Hyperplasia
Park, Sung Yoon , Kim, Chan Kyo , Park, Byung Kwan , Ha, Sang Yun , Kwon, Ghee Young , Kim, Bohyun

American Journal of Roentgenology | February 20, 2014 | Volume: 202 | Issue: 3 | Pages: W254-W262

10.2214/ajr.13.11015 Get It

Diffusion-Weighted Magnetic Resonance Imaging for the Evaluation of Prostate Cancer: Optimal B Value at 3T
Koo, Ji Hyun, Kim, Chan Kyo , Choi, Dongil , Park, Byung Kwan , Kwon, Ghee Young , Koo, Ji Hae , Kim, Bohyun

Korean Journal of Radiology | January 7, 2013 | Volume: 14 | Issue: 1 | Pages: 61

10.3348/kjr.2013.14.1.61 Get It

Evaluation of Transplanted Kidneys Using Blood Oxygenation Level–Dependent MRI at 3 T: A Preliminary Study
Park, Sung Yoon , Kim, Chan Kyo , Park, Byung Kwan , Kim, Sung Ju, Huh, Wooseong , Kim, Bohyun

American Journal of Roentgenology | April 23, 2012 | Volume: 198 | Issue: 5 | Pages: 1108-1114

10.2214/ajr.11.7253 Get It

Utility of Iodine Overlay Technique and Virtual Unenhanced Images for the Characterization of Renal Masses by Dual-Energy CT
Song, Kyoung Doo , Kim, Chan Kyo , Park, Byung Kwan , Kim, Bohyun

American Journal of Roentgenology | November 22, 2011 | Volume: 197 | Issue: 6 | Pages: W1076-W1082

10.2214/ajr.11.6922 Get It

Assessment of Renal Lesions With Blood Oxygenation Level–Dependent MRI at 3 T: Preliminary Experience
Kim, Chan Kyo , Park, Byung Kwan , Kim, EunJu, Min, Ji Hye , Kim, Bohyun

American Journal of Roentgenology | August 23, 2011 | Volume: 197 | Issue: 3 | Pages: W489-W494

10.2214/ajr.10.6319 Get It

MR staging accuracy for endometrial cancer based on the new FIGO stage
Shin, Kyung Eun , Park, Byung Kwan , Kim, Chan Kyo , Bae, Duk Soo, Song, Sang Yong, Kim, Bohyun, Kim, Bohyun

Acta Radiologica | July 8, 2011 | Volume: 52 | Issue: 7 | Pages: 818-824

10.1258/ar.2011.100426 Get It

Background Magnetic resonance imaging (MRI) has been frequently used to determine a preoperative treatment plan for gynecologic cancers. However, the MR accuracy for staging an endometrial cancer is not satisfactory based on the old FIGO staging system. Purpose To evaluate MR accuracy for staging endometrial cancer using the new FIGO staging system. Material and Methods Between January 2005 and May 2009, 199 women underwent surgery due to endometrial cancer. In each patient, an endometrial cancer was staged using MR findings based on the old FIGO staging system and then repeated according to the new FIGO staging system for comparison. Histopathologic findings were used as a standard of reference. Results The accuracy of MRI in the staging of endometrial carcinoma stage I, II, III, and IV using the old FIGO staging system were 80% (159/199), 89% (178/199), 90% (179/199), and 99% (198/199), respectively, compared to 87% (174/199), 97% (193/199), 90% (179/199), and 99% (198/199), respectively, when using the new FIGO staging criteria. The overall MR accuracy of the old and new staging systems were 51% (101/199) and 81% (161/199), respectively. Conclusion MRI has become a more useful tool in the preoperative staging of endometrial cancers using the new FIGO staging system compared to the old one with increased accuracy.
Diffusion-Weighted MRI at 3 T for the Evaluation of Prostate Cancer
Kim, Chan Kyo , Park, Byung Kwan , Kim, Bohyun

American Journal of Roentgenology | May 20, 2010 | Volume: 194 | Issue: 6 | Pages: 1461-1469

10.2214/ajr.09.3654 Get It

High-b-Value Diffusion-Weighted Imaging at 3 T to Detect Prostate Cancer: Comparisons Between b Values of 1,000 and 2,000 s/mm2
Kim, Chan Kyo , Park, Byung Kwan , Kim, Bohyun

American Journal of Roentgenology | December 22, 2009 | Volume: 194 | Issue: 1 | Pages: W33-W37

10.2214/ajr.09.3004 Get It