» Hamstring injuries are common among active and athletic individuals, especially those involved in high-speed running, distance running, or sports requiring sudden directional changes. Acute hamstring strains often occur as an eccentric strain during running or a stretch-type injury caused by simultaneous hip flexion and knee extension. Proximal hamstring tendinopathy is an overuse injury of the hamstring tendon as a result of chronic cicatrization of the musculotendinous unit. » Repeated stress to the hamstring tendon leads to increased cellularity of tendon fibers, disruption of collagen, and subsequent microinjury of the tissue that attaches the tendon to bone. » Management of hamstring injuries generally begins with nonoperative modalities consisting of eccentric rehabilitative exercise programs. Although various other treatment modalities are available, the comparative efficacy of these supportive measures is not well differentiated at this time. » In this article, we review the current literature with regard to the nonoperative treatment of hamstring injuries, specifically focusing on acute hamstring muscle strains and proximal hamstring tendinopathy in order to provide supplementary insight on the effectiveness of current modalities.
An Automated Technique for the Measurement of Limb Occlusion Pressure During Blood Flow Restriction Therapy Is Equivalent to Previous Gold Standard
Purpose To evaluate the efficacy of an automated pneumatic torniquet pump and its ability to automatically calculate the limb occlusion pressure (LOP), as compared with the manual Doppler ultrasound technique. Methods Participants presenting to a Sports Medicine clinic were evaluated for study enrollment. Participants were fitted with a pneumatic tourniquet for the upper and lower extremity. LOP measurements were taken with a Doppler ultrasound or automated SmartCuffs PRO device in a randomized order. Results Final analysis was performed on 96 limbs (48 upper extremities and 48 lower extremities). The study population had a mean age 37.1 ± 14.7 years old and a mean body mass index of 25.47 ± 3.80. The mean measured LOP pressure on the upper extremity with Doppler ultrasound was 174.0 ± 48.7 mm Hg with a range from 120 to 282 mm Hg, whereas the mean measured LOP by the automated pump was 184.0 ± 44.9 mm Hg with a range from 135 to 266 mm Hg. There was no statistically significant difference found between the Doppler LOP and the Smart Cuff upper extremity LOP ( P = .29). When evaluating LOP pressure on the lower extremity the mean LOP found with the Doppler ultrasound was 195.0 ± 31.9 mm Hg with a range from 160 to 272 mm Hg, whereas the automated pump the mean LOP was 205.0 ± 27.1 mm Hg with a range from 168 to 278 mm Hg. There was no statistically significant difference found between the Doppler LOP and the automated pump lower extremity LOP ( P = .09). Conclusions No difference in the personalized LOP measurement was found when comparing an automated pump with the current gold standard of manual Doppler ultrasound. No patients companied of pain or discomfort during the LOP measurement. Level of Evidence Level II, diagnostic: prospective cohort study.