AbstractObjectiveTo investigate the effect of CRYSVITA® (burosumab‐twza) on FGF23 measurements in an intact and a C‐terminal immunoassay.MethodsAn intact serum FGF23 (MedFrontier) and a C‐terminal plasma FGF23 assay (Immutopics) were used. Serum/plasma pools were spiked to span the burosumab therapeutic range (1.4–11.3 μg/ml) and FGF23 recovery was assessed. Patient serum and plasma samples obtained pre and post‐burosumab treatment were evaluated on both assays and compared with corresponding phosphorus measurementsResultsSpiking burosumab (1.4–11.3 μg/ml) into sample pools resulted in a dose‐dependent negative analytical interference on intact FGF23 measurements and no significant interference for C‐terminal FGF23 measurements. However, more than a 500‐fold median increase (post‐ vs. pre‐burosumab administration) in in vivo FGF23 concentrations were observed by both assays.ConclusionsTherapeutic concentrations of burosumab result in a negative analytical interference of the intact, but not the C‐terminal FGF23 immunoassay. Despite this in vitro analytical interference in the intact assay, relatively large elevations of both intact FGF23 and C‐terminal FGF23 measurements were observed in vivo following burosumab administration. Following burosumab administration, FGF23 measurements must be interpreted within the clinical context of the patient and other relevant biomarker results.SummaryThis article describes a negative analytical interference by burosumab in an intact FGF23 immunoassay. The recovery of C‐terminal FGF23 is not significantly affected by the presence of burosumab. In vivo, both assays demonstrate extreme FGF23 elevations in the presence of the drug. Furthermore, the measurement of FGF23 blocked by burosumab is not clinically useful regarding hypophosphataemia.
The Fentanyl Epidemic and Evolution of Fentanyl Analogs in the United States and the European Union
Abstract BACKGROUND Since 2013, an unprecedented surge in fentanyl overdose deaths has been caused by heroin laced with illicitly produced fentanyl and/or fentanyl analogs (FAs) sold as heroin. The US Drug Enforcement Agency's National Forensic Laboratory Information System reported a >300% increase in fentanyl encounters from 4697 in 2014 to 14440 in 2015. In 2015, the CDC reported 9580 deaths caused by synthetic opioids, primarily fentanyl, a 72% increase from 2014. The European Monitoring Centre for Drugs and Drug Addiction has also encountered several new FAs in the heroin supply. Counterfeit pharmaceuticals containing mixtures of fentanyl and FAs continue to be a poorly recognized worldwide problem despite the WHO classifying several FAs as a serious threat to public health. CONTENT This review covers the epidemiology of fentanyl abuse and discusses the clinical practice implications of widespread fentanyl abuse. It includes a historical perspective on the illicit FAs that have appeared in the US and European Union and reviews the methods available to identify FAs and emerging technologies useful for identifying previously undescribed analogs. A compilation of structural and mass spectral data on FAs reported thus far is provided. SUMMARY Fentanyl and FAs have evolved into a global public health threat. It is important to understand the analytical, clinical, and regulatory efforts underway to assist communities affected by the current fentanyl epidemic.
National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Follow-Up Testing for Metabolic Disease Identified by Expanded Newborn Screening Using Tandem Mass Spectrometry; Executive Summary
AbstractBackground: Almost all newborns in the US are screened at birth for multiple inborn errors of metabolism using tandem mass spectrometry. Screening tests are designed to be sufficiently sensitive so that cases are not missed. The NACB recognized a need for standard guidelines for laboratory confirmation of a positive newborn screen such that all babies would benefit from equal and optimal follow-up by confirmatory testing.Methods: A committee was formed to review available data pertaining to confirmatory testing. The committee evaluated previously published guidelines, published methodological and clinical studies, clinical case reports, and expert opinion to support optimal confirmatory testing. Grading was based on guidelines adopted from criteria derived from the US Preventive Services Task Force and on the strength of recommendations and the quality of the evidence. Three primary methods of analyte measurement were evaluated for confirmatory testing including measurement of amino acids, organic acids, and carnitine esters. The committee graded the evidence for diagnostic utility of each test for the screened conditions.Results: Ample data and experience were available to make strong recommendations for the practice of analyzing amino acids, organic acids, and acylcarnitines. Likewise, strong recommendations were made for the follow-up test menu for many disorders, particularly those with highest prevalence. Fewer data exist to determine the impact of newborn screening on patient outcomes in all but a few disorders. The guidelines also provide an assessment of developing technology that will fuel a refinement of current practice and ultimate expansion of the diseases detectable by tandem mass spectrometry.Conclusions: Guidelines are provided for optimal follow-up testing for positive newborn screens using tandem mass spectrometry. The committee regards these tests as reliable and currently optimal for follow-up testing. .