OBJECTIVE: To determine the impact of point-of-care ultrasound (POCUS)-guided resuscitation on clinical outcomes in adult patients with shock. DATA SOURCE: We searched MEDLINE, Embase, and unpublished sources from inception to December 2023. STUDY SELECTION: We included randomized controlled trials (RCTs) that examined the use of POCUS to guide resuscitation in patients with shock. DATA EXTRACTION: We collected data regarding study and patient characteristics, POCUS protocol, control group interventions, and outcomes. DATA SYNTHESIS: We identified 18 eligible RCTs. POCUS slightly influences physicians’ plans for IV fluid (IVF) and vasoactive medication prescription (moderate certainty), but results in little to no changes in the administration of IVF (low to high certainty) or inotropes (high certainty). POCUS may result in no change in the number of CT scans performed (low certainty) but probably reduces the number of diagnostic echocardiograms performed (moderate certainty). POCUS-guided resuscitation probably reduces 28-day mortality (relative risk [RR] 0.88; 95% CI, 0.78–0.99), the duration of vasoactive medication (mean difference –0.73 d; 95% CI, –1.16 to –0.30), and the need for renal replacement therapy (RRT) (RR 0.80; 95% CI, 0.63–1.02) (low to moderate certainty evidence), and lactate clearance (high certainty evidence). POCUS-guided resuscitation may results in little to no difference in ICU or hospital admissions, ICU and hospital length of stay, and the need for mechanical ventilation (MV) (low to moderate certainty evidence). There is an uncertain effect on the risk of acute kidney injury and the duration of MV or RRT (very low certainty evidence). CONCLUSIONS: POCUS-guided resuscitation in shock may yield important patient and health system benefits. Due to lack of sufficient evidence, we were unable to explore how the thresholds of operator competency, frequency, and timing of POCUS scans impact patient outcomes.
Association of Accuracy, Conclusions, and Reporting Completeness With Acceptance by Radiology Conferences and Journals
BackgroundPreferential publication of studies with positive findings can lead to overestimation of diagnostic test accuracy (i.e. publication bias). Understanding the contribution of the editorial process to publication bias could inform interventions to optimize the evidence guiding clinical decisions.Purpose/HypothesisTo evaluate whether accuracy estimates, abstract conclusion positivity, and completeness of abstract reporting are associated with acceptance to radiology conferences and journals.Study TypeMeta‐research.PopulationAbstracts submitted to radiology conferences (European Society of Gastrointestinal and Abdominal Radiology (ESGAR) and International Society for Magnetic Resonance in Medicine (ISMRM)) from 2008 to 2018 and manuscripts submitted to radiology journals (Radiology, Journal of Magnetic Resonance Imaging [JMRI]) from 2017 to 2018. Primary clinical studies evaluating sensitivity and specificity of a diagnostic imaging test in humans with available editorial decisions were included.AssessmentPrimary variables (Youden's index [YI > 0.8 vs. <0.8], abstract conclusion positivity [positive vs. neutral/negative], number of reported items on the Standards for Reporting of Diagnostic Accuracy Studies [STARD] for Abstract guideline) and confounding variables (prospective vs. retrospective/unreported, sample size, study duration, interobserver agreement assessment, subspecialty, modality) were extracted.Statistical TestsMultivariable logistic regression to obtain adjusted odds ratio (OR) as a measure of the association between the primary variables and acceptance by radiology conferences and journals; 95% confidence intervals (CIs) and P‐values were obtained; the threshold for statistical significance was P < 0.05.ResultsA total of 1000 conference abstracts (500 ESGAR and 500 ISMRM) and 1000 journal manuscripts (505 Radiology and 495 JMRI) were included. Conference abstract acceptance was not significantly associated with YI (adjusted OR = 0.97 for YI > 0.8; CI = 0.70–1.35), conclusion positivity (OR = 1.21 for positive conclusions; CI = 0.75–1.90) or STARD for Abstracts adherence (OR = 0.96 per unit increase in reported items; CI = 0.82–1.18). Manuscripts with positive abstract conclusions were less likely to be accepted by radiology journals (OR = 0.45; CI = 0.24–0.86), while YI (OR = 0.85; CI = 0.56–1.29) and STARD for Abstracts adherence (OR = 1.06; CI = 0.87–1.30) showed no significant association. Positive conclusions were present in 86.7% of submitted conference abstracts and 90.2% of journal manuscripts.Data ConclusionDiagnostic test accuracy studies with positive findings were not preferentially accepted by the evaluated radiology conferences or journals.Evidence Level3Technical EfficacyStage 2.