Cost impact of balloon guide catheter with mechanical thrombectomy for acute ischemic stroke: Analysis from the United States, Canada, and seven European countries
Background Balloon guide catheters (BGCs) are adjunctive devices that may be used during mechanical thrombectomy (MT) to induce flow arrest and improve clot retrieval and reperfusion outcomes for acute ischemic stroke. As the cost-effectiveness of BGC use remains uncertain, this study assessed short- and long-term direct healthcare costs associated with BGC use versus standard guide catheters (SGC) during MT. Methods A decision tree model estimated the short-term costs (index hospitalization), long-term costs (one year after index hospitalization), and total costs for patients undergoing MT + BGC versus MT + SGC from a healthcare system perspective in the United States (US), Canada, United Kingdom (UK), Sweden, Germany, Italy, Spain, Belgium, and The Netherlands. Average device costs were sourced from public tender prices and market research data. Weighted average healthcare costs for modified Rankin Scale scores were sourced from published literature for the respective countries. A 2024 meta-analysis supporting improved outcomes with BGC provided input parameters to model treatment effects for BGC and SGC. Deterministic one-way and probabilistic sensitivity analyses evaluated the robustness of model parameters and accounted for uncertainty. Results Across all countries, long-term and total per-patient costs were lower with MT + BGC, yielding total per-patient cost savings of $6297 (US), CAD 3006 (Canada), £1828 (UK), 28,950 kr (Sweden), €1077 (Germany), €709 (Italy), €3678 (Spain), €2259 (Belgium), and €3344 (The Netherlands). The probability of MT + BGC yielding cost savings ranged 0.356–0.911 (short term), 0.962–0.975 (long term), and 0.838–0.935 (total costs). While long-term and total costs consistently favored MT + BGC, short-term cost savings showed more variability across countries. Conclusion This study demonstrates that BGC use is associated with total one-year per-patient cost savings for inpatient and postdischarge stroke care across the US, Canada, and seven European healthcare systems. Balloon guide catheters can potentially reduce post-stroke care costs and should be considered more broadly, despite the additional cost incurred by the device.
The economic impact of stent retriever selection for acute ischemic stroke: a cost analysis of MASTRO I from the healthcare system perspective of the United States, Canada and eight European countries
Aim: According to the results of the MASTRO I living systematic review and meta-analysis, use of the EmboTrap Revascularization ® Device in the treatment of acute ischemic stroke (AIS) results in higher rates of good functional outcomes (90-day modified Rankin Scale [mRS] 0–2) compared with use of the Trevo ® Retriever or the Solitaire™ Revascularization Device. The aim of this analysis was to assess the potential economic impact of achieving improved functional outcomes for three commonly used stent retrievers (SRs) in the treatment of AIS. Methods: An economic model with short-term and long-term costs, representing a healthcare system perspective was developed using a decision tree to simulate a cohort of 1000 hypothetical patients treated for AIS with mechanical thrombectomy (MT) using EmboTrap, Trevo or Solitaire SRs. Based on the proportion of patients who achieved a 90-day mRS score of 0–2 or 3–5 for each device reported in MASTRO I (excluding patients not surviving after 90 days), this model estimated per-patient costs and the associated incremental cost savings. Results are reported from the healthcare system perspective in the US, Canada, the UK, Sweden, Germany, France, Italy, Spain, Belgium and The Netherlands. Results: Across all ten countries, the use of EmboTrap during MT was associated with the lowest short-term (ranging from €8412 in Italy to $66,525 in the US), long-term (ranging from €5249 in Italy to $25,757 in the US) and total (ranging from €13,661 in Italy to $92,282 in the US) per-patient costs. The total per-patient cost was higher with Trevo (ranging from €14,601 in Italy to $97,487 in the US) and Solitaire (ranging from €14,840 in Italy to $98,814 in the US). Cost savings were highest when comparing EmboTrap versus Solitaire, followed by EmboTrap versus Trevo, with Trevo versus Solitaire having the smallest cost savings. Results of sensitivity and scenario analyses supported the robustness of the base-case results. Conclusion: Across the ten countries, treating patients with AIS with EmboTrap resulted in lower short-term, long-term and total costs to the payer. With rising healthcare costs and limited hospital budgets, these results suggest EmboTrap proves to be an evidence-based economical choice of SR for hospitals and healthcare systems.
The economic impact associated with stent retriever selection for the treatment of acute ischemic stroke: a cost–effectiveness analysis of MASTRO I data from a Chinese healthcare system perspective
Aim: The aim of this analysis was to assess the cost–effectiveness of the EmboTrap ® Revascularization Device compared with the Solitaire™ Revascularization Device and Trevo ® Retriever for the treatment of acute ischemic stroke (AIS) from the perspective of the Chinese healthcare system. Methods: According to MASTRO I, a recent living systematic literature review and meta-analysis, mechanical thrombectomy (MT) with EmboTrap in the treatment of AIS resulted in better functional outcomes compared with the use of Solitaire or Trevo. Based on the proportion of patients that achieved 90-day modified Rankin Scale (mRS) scores of 0–2, 3–5 and 6 reported in MASTRO I, a combined 90-day short-term decision tree and Markov model with a 10-year time horizon was used to compare the cost–effectiveness of the three devices. The primary outcome was the incremental cost–effectiveness ratio (ICER), representing the incremental cost (in 2022 Chinese Yuan [CNY]) per incremental quality-adjusted life-year (QALY). The ICERs were compared against willingness-to-pay (WTP) thresholds of 1, 1.5 and 3-times the 2022 national gross domestic product (GDP) per capita in China. Results: Treatment with EmboTrap resulted in total QALYs of 3.28 and total costs of 110,058 CNY per patient. Treatment with Trevo resulted in total QALYs of 3.05 and total costs of 116,941 CNY per patient. Treatment with Solitaire resulted in total QALYs of 2.81 and total costs of 99,090 CNY per patient. Trevo was dominated by EmboTrap as it was a more costly and less effective intervention. As such, Trevo was not cost-effective at any WTP threshold. Compared with Solitaire, EmboTrap was more effective and more costly, with an ICER of 23,615 CNY per QALY. This result suggests that EmboTrap is cost-effective when compared with Solitaire since the ICER was lower than all WTP thresholds assessed. Conclusion: EmboTrap dominated Trevo and is cost-effective for the treatment of patients with AIS compared with Solitaire when assessed from the perspective of the Chinese healthcare system and based on the device-level meta-analysis MASTRO I. Selecting a stent retriever (SR) that optimizes 90-day mRS score is an important consideration from both a clinical and healthcare payer perspective in China as it is associated with reduced long-term costs and increased quality of life.
Estimating the impact of balloon guide catheter with mechanical thrombectomy for acute ischemic stroke: A U.S. cost analysis
Background Balloon guide catheters (BGCs) can be used adjunctively during mechanical thrombectomy (MT) for acute ischemic stroke (AIS). Evaluating the potential economic impact associated with adjunctive BGC use is an important consideration for resource allocation. Methods Decision tree models were used to estimate the economic value of BGC use in MT through its impact on functional outcomes. Healthcare utilization cost estimates in the short- and long-term for patients with different 90-day mRS scores were analyzed for MT-only and MT + BGC scenarios. Deterministic (one-way) and probabilistic sensitivity analyses were performed to evaluate the robustness and uncertainty of model parameters. Results Per-patient index hospitalization cost was estimated at $65,260 for MT-only and $62,883 for MT + BGC scenarios. Per-patient one-year post-index hospitalization cost was estimated at $27,569 for MT-only and $24,830 for MT + BGC. MT + BGC had a total cost savings of $5117 compared with MT-only. Deterministic (one-way) sensitivity analysis demonstrated that cost saving per patient was most sensitive to the proportion of patients in the mRS 0–2 category in both MT + BGC and MT-only. In a probabilistic sensitivity analysis, mean per-patient costs for the index hospitalization were estimated at $63,737 for MT-only and $61,425 for MT + BGC. Mean per-patient cost estimates one-year post-index hospitalization was $27,445 for MT-only and $24,715 for MT + BGC. MT + BGC had a total cost savings of $5043 compared with MT-only. Conclusion Mechanical thrombectomy with adjunctive BGC use may reduce short-term and long-term patient costs due to improved functional outcomes when compared to MT treatment alone for AIS.
Evidence-Based Disparities in Stroke Care Metrics and Outcomes in the United States: A Systematic Review
Stroke disproportionately affects racial minorities, and the level to which stroke treatment practices differ across races is understudied. Here, we performed a systematic review of disparities in stroke treatment between racial minorities and White patients. A systematic literature search was performed on PubMed to identify studies published from January 1, 2010, to April 5, 2021 that investigated disparities in access to stroke treatment between racial minorities and White patients. A total of 30 studies were included in the systematic review. White patients were estimated to use emergency medical services at a greater rate (59.8%) than African American (55.6%), Asian (54.7%), and Hispanic patients (53.2%). A greater proportion of White patients (37.4%) were estimated to arrive within 3 hours from onset of stroke symptoms than African American (26.0%) and Hispanic (28.9%) patients. A greater proportion of White patients (2.8%) were estimated to receive tPA (tissue-type plasminogen activator) as compared with African American (2.3%), Hispanic (2.6%), and Asian (2.3%) patients. Rates of utilization of mechanical thrombectomy were also lower in minorities than in the White population. As shown in this review, racial disparities exist at key points along the continuum of stroke care from onset of stroke symptoms to treatment. Beyond patient level factors, these disparities may be attributed to other provider and system level factors within the health care ecosystem.
Real-world outcomes associated with the use of the EmboTrap revascularization device for ischemic stroke in the United States
Background Mechanical thrombectomy (MT) has become the standard of care for the treatment of acute ischemic stroke (AIS). The EmboTrap revascularization device (CERENOVUS, Johnson & Johnson Medical Devices, Irvine, California, USA) has an innovative, dual layer feature designed to facilitate thrombus retrieval. Objective To investigate the real-world clinical and economic outcomes among patients with AIS undergoing MT using the EmboTrap device in the United States (US). Methods Adult patients (≥18 years) who underwent MT for AIS using the EmboTrap device between July 2018 and December 2020 were identified from the Premier Healthcare Database. Patient outcomes included discharge status (including in-hospital mortality), mean length of stay (LOS), intracranial hemorrhage (ICH), mean hospital costs, and 30-day readmissions (all-cause, cardiovascular (CV)-related, and AIS-related). Results A total of 318 patients (mean age 68.5±14.6 years) with AIS treated with the EmboTrap device as the only stent retriever used were identified. Approximately 25% of patients were discharged to home/home health organization, and the in-hospital mortality rate was 10.7%. The rate of ICH was 16.7%. Mean hospital LOS was 9.9±11.3 days, and the mean hospital costs were US$47 367±30 297. The 30-day readmission rate was 9.6% for all-causes, 5.9% for CV-related causes, and 2.6% for AIS-related causes. Conclusions This is the first study in the US to report real-world outcomes sourced by retrospective database analysis among patients with AIS undergoing MT using the EmboTrap device. Further research is needed to better understand performance of the EmboTrap device in real-world settings.