Back to Authors

Ruiter, Godard C. W. de

https://orcid.org/0000-0003-0764-8048

Mayo Clinic

Mayo Clinic

Citations 16

Innervation of the anconeus epitrochlearis muscle: MRI and cadaveric studies
Collin, Peter G., Ishak, Basem , Iwanaga, Joe , Amrami, Kimberly K. , Ringler, Michael D. , Ruiter, Godard C. W. de , Spinner, Robert J. , Tubbs, R. Shane , Tubbs, R Shane , Iwanaga, Joe , Grewal, Sanjeet S.

Clinical Anatomy | September 29, 2018 | Volume: 32 | Issue: 2 | Pages: 218-223

10.1002/ca.23285 Get It

Ulnar neuropathy at the cubital tunnel is common. However, a rare form of ulnar neuropathy here is due to compression from an accessory muscle, the anconeus epitrochlearis. Reports in the literature regarding the details of this muscle's innervation are vague, so the aim of the present study was to characterize this anatomy more clearly. This was a combined review of magnetic resonance imaging (MRI) from patients with an anconeus epitrochlearis and ulnar neuropathy and cadaveric dissections to characterize the innervation of this variant muscle. A review of 11 patients and three reports of ulnar neuropathy and an anconeus epitrochlearis in the literature revealed no MRI changes consistent with acute denervation of this muscle. However, in two cases, there were signs of chronic denervation of the muscle. Dissection of five cadavers revealed that the nerve supply to the anconeus epitrochlearis originated proximal to the medial epicondyle, traveled parallel to the ulnar nerve, terminated on the deep aspect of this muscle, and had a mean length of 60 mm. This clinicoanatomical study provides evidence that the innervation of the anconeus epitrochlearis is proximal to the muscle and on its deep aspect. Clin. Anat. 32:218–223, 2019. © 2018 Wiley Periodicals, Inc.
The subparaneurial compartment: A new concept in the clinicoanatomic classification of peripheral nerve lesions
Prasad, Nikhil K. , Capek, Stepan , Ruiter, Godard C. W. de , Amrami, Kimberly K. , Spinner, Robert J.

Clinical Anatomy | July 2, 2015 | Volume: 28 | Issue: 7 | Pages: 925-930

10.1002/ca.22589 Get It

Based on our experience in treating peripheral non‐neural sheath derived pathology, we have identified a novel pattern of lesion progression along the anatomic course of nerves. This report highlights the existence of a subparaneurial compartment around peripheral nerves. We first applied an anatomic framework to review MR images and intraoperative photographs of patients treated by the senior author in the last 10 years. After identifying a pattern that was consistent with subparaneurial lesion progression, we searched for other examples of cases that might exhibit this pattern. Four examples of subparaneurial pathology were identified, a hemangioma of the ulnar nerve, a ganglion cyst of the common fibular nerve, a lymphoma of the sciatic nerve and a lipoma of the ulnar nerve. All four patients were operated on and had intraoperative photographs; three had high resolution MR imaging. This report highlights the existence of pathology contained within a subparaneurial compartment, outside of the epineurium, that follows the course of the nerve and surrounds it circumferentially. The subparaneurial localization of peripheral nerve lesions has hitherto received little attention. Identification of this new pattern on preoperative MRI may have implications for surgical management. Clin. Anat. 28:925–930, 2015. © 2015 Wiley Periodicals, Inc.
Molecularly Engineered Biodegradable Polymer Networks with a Wide Range of Stiffness for Bone and Peripheral Nerve Regeneration
Wang, Shanfeng , Ruiter, Godard C. W. de , Spinner, Robert J. , Windebank, Anthony J. , Yaszemski, Michael J. , Lu, Lichun , Kempen, Diederik H.R. , Cai, Lei

Advanced Functional Materials | March 24, 2015 | Volume: 25 | Issue: 18 | Pages: 2715-2724

10.1002/adfm.201500105 Get It

To satisfy different mechanical requirements in hard and soft tissue replacements, a series of biodegradable and crosslinkable copolymers of poly(propylene fumarate)‐co‐polycaprolactone (PPF‐co‐PCL) are synthesized and employed to fabricate 2D disks and 3D scaffolds via photocrosslinking. Thermal properties such as the glass transition temperature (Tg) and melting temperature (Tm) of the PPF‐co‐PCL networks can be controlled efficiently by varying the PCL composition (φPCL). As a result, their mechanical properties vary significantly from hard and stiff materials to soft and flexible ones with increasing φPCL, making them attractive candidate materials for bone and peripheral nerve regeneration, respectively. Several PPF‐co‐PCL formulations are selected to perform in vitro cell studies using mouse pre‐osteoblastic MC3T3‐E1, rat Schwann cell precursor line (SPL201), and pheochromocytoma (PC12) cells, and in vivo animal testing in the rat femur bone defect model and in the rat sciatic nerve transection model. The formation of new bone in the porous bone scaffolds with a low φPCL and guided axon growth through the nerve conduits with a higher φPCL suggest that crosslinked PPF‐co‐PCLs have appropriate compatibility and functionality. Furthermore, the role of surface stiffness in modulating cellular behavior and functions is verified on the crosslinked PPF‐co‐PCL surfaces without any pretreatments.
Misdirection and guidance of regenerating axons after experimental nerve injury and repair
Ruiter, Godard C. W. de , Spinner, Robert J. , Verhaagen, Joost , Malessy, Martijn J. A.

Journal of Neurosurgery | October 11, 2013 | Volume: 120 | Issue: 2 | Pages: 493-501

10.3171/2013.8.jns122300 Get It

Misdirection of regenerating axons is one of the factors that can explain the limited results often found after nerve injury and repair. In the repair of mixed nerves innervating different distal targets (skin and muscle), misdirection may, for example, lead to motor axons projecting toward skin, and vice versa—that is, sensory axons projecting toward muscle. In the repair of motor nerves innervating different distal targets, misdirection may result in reinnervation of the wrong target muscle, which might function antagonistically. In sensory nerve repair, misdirection might give an increased perceptual territory. After median nerve repair, for example, this might lead to a dysfunctional hand. Different factors may be involved in the misdirection of regenerating axons, and there may be various mechanisms that can later correct for misdirection. In this review the authors discuss these different factors and mechanisms that act along the pathway of the regenerating axon. The authors review recently developed evaluation methods that can be used to investigate the accuracy of regeneration after nerve injury and repair (including the use of transgenic fluorescent mice, retrograde tracing techniques, and motion analysis). In addition, the authors discuss new strategies that can improve in vivo guidance of regenerating axons (including physical guidance with multichannel nerve tubes and biological guidance accomplished using gene therapy).
Axon Regeneration through Scaffold into Distal Spinal Cord after Transection
Chen, Bing Kun, Ruiter, Godard C. W. de , Spinner, Robert J. , Yaszemski, Michael J. , Currier, Bradford L. , Windebank, Anthony J. , Knight, Andrew Michael

Journal of Neurotrauma | June 23, 2009 | Volume: 26 | Issue: 10 | Pages: 1759-1771

10.1089/neu.2008.0610 Get It

Designing ideal conduits for peripheral nerve repair
Ruiter, Godard C. W. de , Yaszemski, Michael J. , Windebank, Anthony J. , Spinner, Robert J. , Malessy, Martijn J. A.

Neurosurgical Focus | January 30, 2009 | Volume: 26 | Issue: 2 | Pages: E5

10.3171/foc.2009.26.2.e5 Get It

Nerve tubes, guides, or conduits are a promising alternative for autologous nerve graft repair. The first biodegradable empty single lumen or hollow nerve tubes are currently available for clinical use and are being used mostly in the repair of small-diameter nerves with nerve defects of < 3 cm. These nerve tubes are made of different biomaterials using various fabrication techniques. As a result these tubes also differ in physical properties. In addition, several modifications to the common hollow nerve tube (for example, the addition of Schwann cells, growth factors, and internal frameworks) are being investigated that may increase the gap that can be bridged. This combination of chemical, physical, and biological factors has made the design of a nerve conduit into a complex process that demands close collaboration of bioengineers, neuroscientists, and peripheral nerve surgeons. In this article the authors discuss the different steps that are involved in the process of the design of an ideal nerve conduit for peripheral nerve repair.