Back to Authors

Young, Phillip M.

https://orcid.org/0000-0002-8747-8810

Mayo Clinic

Mayo Clinic

Citations 36

Buildup of image quality in view‐shared time‐resolved 3D CE‐MRA
Johnson, Casey P. , Polley, Thomas W., Glockner, James F., Young, Phillip M. , Riederer, Stephen J.

Magnetic Resonance in Medicine | August 30, 2012 | Volume: 70 | Issue: 2 | Pages: 348-357

10.1002/mrm.24466 Get It

Time‐resolved three‐dimensional contrast‐enhanced MR angiography often relies on view sharing of peripheral k‐space data to enable acquisition of angiograms with both high spatial resolution and a rapid frame rate. It is typically assumed that k‐space will be fully sampled during passage of the contrast bolus arterial phase. However, this is not the case when view sharing is incomplete, for example, at the leading edge of an enhancing vessel or if acquisition time is limited as in fluoroscopic tracking for multistation bolus chase MR angiography. Incomplete view sharing will degrade image quality, for example, by reducing vessel signal and sharpness and increasing undersampling artifacts. In this work, the evolution of angiogram quality with view sharing is quantitatively assessed in phantom experiments and in vivo contrast‐enhanced MR angiography calf studies. It is demonstrated that there are multiple sets of sequence parameters that can yield a target image update time, but the choice of parameters can profoundly affect how image quality evolves with view sharing. A fundamental tradeoff between vessel signal and sharpness and its relationship to the sequence temporal footprint is investigated and discussed. Magn Reson Med 70:348–357, 2013. © 2012 Wiley Periodicals, Inc.
Cardiac Imaging: Part 2, Normal, Variant, and Anomalous Configurations of the Coronary Vasculature
Young, Phillip M. , Gerber, Thomas C., Williamson, Eric E. , Julsrud, Paul R., Herfkens, Robert J.

American Journal of Roentgenology | September 21, 2011 | Volume: 197 | Issue: 4 | Pages: 816-826

10.2214/ajr.10.7249 Get It

Respiratory Navigated Free Breathing 3D Spoiled Gradient-Recalled Echo Sequence for Contrast-Enhanced Examination of the Liver: Diagnostic Utility and Comparison With Free Breathing and Breath-Hold Conventional Examinations
Young, Phillip M. , Brau, Anja, Iwadate, Yuji , Vasanawala, Shreyas , Tamrazi, Anobel, Herfkens, Robert J., Daniel, Bruce Lewis

American Journal of Roentgenology | August 20, 2010 | Volume: 195 | Issue: 3 | Pages: 687-691

10.2214/ajr.09.3892 Get It

Imaging Spectrum of Bites, Stings, and Their Complications: Self-Assessment Module
Roberts, Catherine C. , Young, Phillip M. , Bancroft, Laura W. , Liu, Patrick T., Peterson, Jeffrey J.

American Journal of Roentgenology | August 20, 2009 | Volume: 193 | Issue: 3_supplement | Pages: S42-S45

10.2214/ajr.09.7171 Get It

Imaging Spectrum of Bites, Stings, and Their Complications: Pictorial Review
Young, Phillip M. , Bancroft, Laura W. , Peterson, Jeffrey J., Roberts, Catherine C. , Liu, Patrick T., Zaleski, Christopher G.

American Journal of Roentgenology | August 20, 2009 | Volume: 193 | Issue: 3_supplement | Pages: S31-S41

10.2214/ajr.07.7123 Get It

Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort
Nottmeier, Eric W. , Seemer, Will, Young, Phillip M.

Journal of Neurosurgery: Spine | January 2, 2009 | Volume: 10 | Issue: 1 | Pages: 33-39

10.3171/2008.10.spi08383 Get It

Object The goal of this study was to analyze the placement accuracy and complications of thoracolumbar pedicle screws (PSs) inserted using 3D image guidance in a large patient cohort. Methods The authors reviewed the charts of 220 consecutive patients undergoing posterior spinal fusion using 3D image guidance for instrumentation placement. A total of 1084 thoracolumbar PSs were placed using either the BrainLAB Vector Vision (BrainLAB, Inc.) or Medtronic StealthStation Treon (Medtronic, Inc.) image guidance systems. Postoperative CT scanning was performed in 184 patients, allowing for 951 screws to be graded by an independent radiologist for bone breach. All complications resulting from instrumentation placement were noted. Using the intraoperative planning function of the image-guided system, the largest diameter screw possible in each particular case was placed. The screw diameter of instrumentation placed into the L3–S1 levels was noted. Results No vascular or visceral complications occurred as a result of screw placement. Two nerve root injuries occurred in 1084 screws placed, resulting in a 0.2% per screw incidence and a 0.9% patient incidence of nerve root injury. Neither nerve root injury was associated with a motor deficit. The breach rate was 7.5%. Grade 1 and minor anterolateral “tip out” breaches accounted for 90% of the total breaches. Patients undergoing revision surgery accounted for 46% of the patients in this study. Accordingly, 154 screws placed through previous fusion mass could be evaluated using postoperative CT scanning. The breach rate in this specific cohort was 7.8%. A total of 765 PSs were placed into the L3–S1 levels in this study; 546 (71%) of these screws were ≥ 7.5 mm in diameter. No statistical difference in breach rate was noted in PSs placed through revision spinal levels versus nonrevision spinal levels (p = 0.499). Additionally, no increase in breach rate was noted with placement of 7.5-mm-diameter screws. Conclusions Three-dimensional image guidance is a useful adjunct to placement of spinal instrumentation. The complication rate in this study was low, and accurate placement of instrumentation was achieved despite the high percentage of revision surgery cases in our patient population. Additionally, because active fluoroscopy was not used for instrumentation placement, there was minimal to no radiation exposure to the surgeon or operating room staff.