Back to Authors

Bridgeman, Amber R.

https://orcid.org/0000-0003-0499-3954

Mayo Clinic

Mayo Clinic

Citations 5

Chromosome-arm-specific telomere length governs dual modes of structural genome evolution in IDH-mutant astrocytoma
Jehangir, Maryam , Drucker, Kristen , Keskus, Ayse G. , Ranallo-Benavidez, T R, Benamozig, Orléna , Kollmeyer, Thomas , Giannini, Caterina , Kipp, Benjamin R. , Murphy, Stephen James, Bridgeman, Amber R. , Walsh, Jesse R. , Majumdar, Ramanath, Lachance, Daniel H , Eckel‐Passow, Jeanette E. , Jenkins, RB , Kollmeyer, Thomas M. , Ranallo-Benavidez, T. Rhyker , Drucker, Kristen L , Keskus, Ayse , Ranallo-Benavidez, T Rhyker , Giannini, Caterina , Kipp, Benjamin , Bridgeman, Amber R , Walsh, Jesse R , Lachance, Daniel , Eckel-Passow, Jeanette E , Shoshani, Ofer , Kolmogorov, Mikhail , Barthel, Floris P , Jehangir, Maryam , Burns, Terry C. , Jenkins, Robert B.

No container title available | April 23, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.04.22.720226 Get It

ABSTRACT IDH-mutant astrocytomas maintain telomeres through the alternative lengthening of telomeres (ALT) pathway, producing extreme inter-arm telomere length heterogeneity, yet how this heterogeneity shapes structural genome evolution remains unknown. Using Oxford Nanopore long-read sequencing of 20 IDH-mutant astrocytomas, we profiled structural variants (SVs), copy number variants, extrachromosomal DNA (ecDNA) and measured allele-specific telomere lengths from individual long reads. We identified pervasive complex rearrangements, including chromothripsis and foldback events consistent with breakage-fusion-bridge cycles, and widespread ecDNAs. SV breakpoints were enriched at telomeric and centromeric regions regardless of local telomere length, revealing constitutive structural fragility. Arm-level telomere length analysis uncovered a dual-mode model: arms with short telomeres preferentially harbored breakage-associated events, while arms with long ALT-maintained telomeres were enriched for ecDNA and amplification-associated events. These findings identify chromosome-arm-specific telomere length as a determinant of structural genome evolution in ALT-driven tumors.
Utility of methylated DNA markers for the diagnosis of malignant biliary strictures
Cooley, Matthew A. , Schneider, Amber, Fritcher, Emily G. Barr , Milosevic, Dragana , Levy, Michael J. , Bridgeman, Amber R. , Martin, John A. , Petersen, Bret T. , Dayyeh, Barham K. Abu , Law, Ryan , Garimella, Vishal, Jenkins, Sarah M. , Yin, Jun, Roberts, Lewis R. , Kipp, Benjamin R. , Ferrándiz‐Pulido, Carla , Schneider, Amber R, Abu Dayyeh, Barham K , Storm, Andrew C , Law, Ryan J, Vargas, Eric J , Roberts, Lewis R , Kipp, Benjamin , Chandrasekhara, Vinay , Barr Fritcher, Emily G , Bridgeman, Amber R , Levy, Michael J. , Storm, Andrew C. , Vargas, Eric J. , Zemla, Tyler , Gores, Gregory J. , Chandrasekhara, Vinay

Hepatology | June 21, 2024 | Volume: 81 | Issue: 2 | Pages: 453-464

10.1097/hep.0000000000000970 Get It

Background and Aims: Early identification of malignant biliary strictures (MBSs) is challenging, with up to 20% classified as indeterminants after preliminary testing and tissue sampling with endoscopic retrograde cholangiopancreatography. We aimed to evaluate the use of methylated DNA markers (MDMs) from biliary brushings to enhance MBS detection in a prospective cohort. Approach: Candidate MDMs were evaluated for their utility in MBS diagnosis through a series of discovery and validation phases. DNA was extracted from biliary brushing samples, quantified, bisulfite-converted, and then subjected to methylation-specific droplet digital polymerase chain reaction. Patients were considered to have no malignancy if the sampling was negative and there was no evidence of malignancy after 1 year or definitive negative surgical histopathology. Results: Fourteen candidate MDMs were evaluated in the discovery phase, with top-performing and new markers evaluated in the technical validation phase. The top 4 MDMs were TWIST1, HOXA1, VSTM2B, and CLEC11A, which individually achieved AUC values of 0.82, 0.81, 0.83, and 0.78, respectively, with sensitivities of 59.4%, 53.1%, 62.5%, and 50.0%, respectively, at high specificities for malignancy of 95.2%–95.3% for the final biologic validation phase. When combined as a panel, the AUC was 0.86, achieving 73.4% sensitivity and 92.9% specificity, which outperformed cytology and fluorescence in situ hybridization (FISH). Conclusions: The selected MDMs demonstrated improved performance characteristics for the detection of MBS compared to cytology and FISH. Therefore, MDMs should be considered viable candidates for inclusion in diagnostic testing algorithms.
Evaluating User Experience and DNA Yield from Self-Collection Devices
Blommel, Joseph H. , Roforth, Matthew M., Jerde, Calvin R. , Karsten, Carley A., Bridgeman, Amber R. , Voss, Jesse S. , Ivankovic, Diana S., Kipp, Benjamin R. , Boccuto, Luigi , Sarasua, Sara M. , Murphy, Stephen J.

The Journal of Applied Laboratory Medicine | May 20, 2024 | Volume: 9 | Issue: 4 | Pages: 704-715

10.1093/jalm/jfae030 Get It

Abstract Background The COVID-19 pandemic emphasized an urgent need for devices used in the self-collection of biospecimens in an evolving patient care system. The mailing of biospecimen self-collection kits to patients, with samples returned via mail, provides a more convenient testing regimen, but could also impart patient sampling variabilities. User compliance with device directions is central to downstream testing of collected biospecimens and clear instructions are central to this goal. Methods Here, we performed an evaluation of 10 oral DNA collection devices involving either swab or saliva self-collection and analyzed ease of use and comfort level with a device, as well as DNA recovery quantity/quality and sample stability. Results We show that while these DNA quality/quantity metrics are comparable between devices, users prefer direct saliva collection over swab-based devices. Conclusions This information is useful in guiding future experiments including their use in human RNA, microbial, or viral sample collection/recovery and their use in clinical testing.
Abstract 3484: Development of a custom high-plex GeoMx digital spatial profiler breast cancer protein biomarker assay
Corless, Christopher L. , Bridgeman, Amber R. , Geiss, Gary , Warren, Sarah , Church, S. , Beechem, Joseph , Thompson, E. Aubrey , Lee, Jin‐Ho , Church, SE, Carter, Jodi M.

Cancer Research | June 15, 2022 | Volume: 82 | Issue: 12_Supplement | Pages: 3484-3484

10.1158/1538-7445.am2022-3484 Get It

Abstract The goal of this study was to develop a high-plex assay to simultaneously quantitate 27 established and novel breast cancer (BC)-related, immune protein and phosphoprotein biomarkers using the GeoMx® Digital Spatial Profiler (DSP). The custom assay performance was compared to standard clinical BC biomarker assays (e.g.ER, PR, HER2, Ki67) across the spectrum of BC subtypes and in multiple laboratories. Commercially available antibodies to 27 BC-related protein biomarkers, including ER, PR, HER2, Ki-67, AR, immune-related (e.g. PD-L1) and several cell cycle/proliferation markers were oligonucleotide-tagged, and verified by immunohistochemistry for performance against untagged antibodies. The tagged antibodies were combined with 3 isotype controls and 2 housekeeping proteins into a custom BC high-plex assay for DSP. Confirmation of target specificity was done on a custom tissue microarray (TMA) (Run control) composed of (un)treated cancer cell lines and normal tissues. For clinical BC samples, each biopsy had 4x600 µm regions of interest segmented into pan-Cytokeratin+ tumoral epithelium and pan-Cytokeratin- adjacent stroma segments. With targeted UV light, oligonucleotides were collected from each segment sequentially and quantitated with nCounter. Raw counts were geomean normalized for analysis. Intra-site and inter-site assay reproducibility was assessed with the TMA and serial FFPE sections from BC biopsies. Quantitation of proteins showed high reproducibility within sites (e.g. Run 1 v. Run 2, p>0.05 for all protein targets) and the high-plex custom assay showed good concordance between 3 participating laboratories. GeoMx DSP-derived protein data correlated well with orthogonal methodologies performed on a sample subset including immunohistochemistry, reverse phase protein array, DNA and RNA-sequencing. For example, DSP protein counts for p53 protein were higher in tumors with TP53 point mutation than those with truncating TP53 alterations. Expanded sample testing is underway with 120 well-characterized breast cancer biopsies of various histologies, immune subtypes (e.g. TIL scores) and clinical biomarker phenotypes (e.g. ER+/HER2-/Ki-67 high BC; ER+/HER2-/Ki-67 low BC; HER2+ BC; ER-/PR-/HER2- BC).Our preliminary data demonstrate that this custom high-plex BC assay can quantitate protein biomarkers across a wide dynamic range with high intra-lab and inter-lab reproducibility. The assay requirement of a single 5-µm tissue section facilitates complex biomarker profiling in biopsies with limited material. The custom assay alone or in combination with other targeted DSP protein modules can simultaneously interrogate the biomarker profile, immune-based and other drug target profile, and immune microenvironment of BC specimens, providing a novel approach for actionable tumor subtyping. For research use only. Not for use in diagnostic procedures. Citation Format: Christopher Corless, Amber Bridgeman, Jinho Lee, Gary Geiss, Sarah Warren, Sarah Church, Joseph M. Beechem, E Aubrey Thompson, Jodi Carter. Development of a custom high-plex GeoMx digital spatial profiler breast cancer protein biomarker assay [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2022; 2022 Apr 8-13. Philadelphia (PA): AACR; Cancer Res 2022;82(12_Suppl):Abstract nr 3484.
Analytical Sensitivity and Specificity of Four Point of Care Rapid Antigen Diagnostic Tests for SARS-CoV-2 Using Real-Time Quantitative PCR, Quantitative Droplet Digital PCR, and a Mass Spectrometric Antigen Assay as Comparator Methods
Karon, Brad S. , Bridgeman, Amber R. , Blommel, Joseph H. , Kipp, Benjamin R. , Renuse, Santosh , Kemp, Jennifer, Madugundu, Anil K. , Vanderboom, Patrick M. , Dasari, Surendra , Grebe, Stefan K. , Pandey, Akhilesh , Donato, Leslie J. , Kipp, Benjamin, Maus, Anthony , Pandey, Akhilesh , Chavan, Sandip , Pandey, Akhilesh , Singh, Ravinder

Clinical Chemistry | July 2, 2021 | Volume: 67 | Issue: 11 | Pages: 1545-1553

10.1093/clinchem/hvab138 Get It

Abstract Background We evaluated the analytical sensitivity and specificity of 4 rapid antigen diagnostic tests (Ag RDTs) for severe acute respiratory syndrome coronavirus 2, using reverse transcription quantitative PCR (RT-qPCR) as the reference method and further characterizing samples using droplet digital quantitative PCR (ddPCR) and a mass spectrometric antigen test. Methods Three hundred fifty (150 negative and 200 RT-qPCR positive) residual PBS samples were tested for antigen using the BD Veritor lateral flow (LF), ACON LF, ACON fluorescence immunoassay (FIA), and LumiraDx FIA. ddPCR was performed on RT-qPCR–positive samples to quantitate the viral load in copies/mL applied to each Ag RDT. Mass spectrometric antigen testing was performed on PBS samples to obtain a set of RT-qPCR–positive, antigen-positive samples for further analysis. Results All Ag RDTs had nearly 100% specificity compared to RT-qPCR. Overall analytical sensitivity varied from 66.5% to 88.3%. All methods detected antigen in samples with viral load >1 500 000 copies/mL RNA, and detected ≥75% of samples with viral load of 500 000 to 1 500 000 copies/mL. The BD Veritor LF detected only 25% of samples with viral load between 50 000 to 500 000 copies/mL, compared to 75% for the ACON LF device and >80% for LumiraDx and ACON FIA. The ACON FIA detected significantly more samples with viral load <50 000 copies/mL compared to the BD Veritor. Among samples with detectable antigen and viral load <50 000 copies/mL, sensitivity of the Ag RDT varied between 13.0% (BD Veritor) and 78.3% (ACON FIA). Conclusions Ag RDTs differ significantly in analytical sensitivity, particularly at viral load <500 000 copies/mL.