Ritman, Erik L.

Mayo Clinic

Mayo Clinic

Citations 68

Altered Myocardial Microvascular 3D Architecture in Experimental Hypercholesterolemia
Rodriguez‐Porcel, Martin , Ritman, Erik L., Best, Patricia J.M. , Lerman, Lilach O. , Lerman, Amir , Wilson, Stephanie H.

Circulation | June 12, 2012 | Volume: 102 | Issue: 17 | Pages: 2028-2030

10.1161/01.cir.102.17.2028 Get It

Background —Experimental hypercholesterolemia (HC) impairs intramyocardial microvascular function. However, whether this is associated with alterations in microvascular architecture remained unknown. Using a novel 3D micro-CT scanner, we tested the hypothesis that HC is associated with an alteration in the microvascular architecture. Methods and Results —Pigs were euthanized after 12 weeks of either normal (n=6) or 2% HC (n=6) diet. The hearts were excised and the coronary arteries injected with a radiopaque contrast material. Myocardial samples were scanned with micro-CT, and 3D images were reconstructed with 21-μm cubic voxels. The myocardium was tomographically subdivided into subepicardium and subendocardium, and microvessels (<500 μm in diameter) were counted in situ within each region. In the subendocardium of HC pigs, the intramyocardial density of microvessels was significantly higher than in normal animals (1221.4±199.7 versus 758.3±90.8 vessels/cm 3 , P <0.05) because of an increase in the number of microvessels <200 μm in diameter (1214.4±199.7 versus 746.6±101.5 vessels/cm 3 , P <0.05). The subepicardial vascular density was similar in both groups. Conclusions —HC has differential effects on the spatial density of the subendocardial microvasculature that may play a role in regulation and/or spatial distribution of myocardial blood flow. This study also demonstrates the feasibility of studying myocardial microvascular architecture with micro-CT in pathophysiological states.
Impact of Acute Pulmonary Rejection on Cardiac Function
McLarty, Allison J., McGregor, Christopher G.A. , Shu, Nai H., Miller, Virginia M. , Ritman, Erik L.

Circulation | June 12, 2012 | Volume: 91 | Issue: 1 | Pages: 186-191

10.1161/01.cir.91.1.186 Get It

Background Experiments were designed to define cardiac function in dogs with single lung allografts during acute rejection of the allografted lung. Methods and Results Left lungs were either autotransplanted (n=4) or allotransplanted (n=8) in adult male mongrel dogs. All allotransplanted animals were maintained on triple-drug immunosuppression (cyclosporine, azathioprine, and steroids) for 5 days after the operation. In 4 allotransplanted animals, treatment was discontinued, allowing the animals to reject (usually after a further 3 days; rejecting group); 4 other allotransplanted animals were maintained on immunosuppression for an additional 3 days (immunosuppressed group). Another group of dogs were not operated on but were maintained on the same immunosuppression as the rejecting group (controls). All experimental animals underwent fast computed tomographic scanning with measurement of left ventricular pressure and calculation of ventricular chamber volumes, cross-sectional areas of coronary arteries, myocardial perfusion, and intramyocardial blood volume. Neither cardiac output, left ventricular mass, left ventricular pressure, nor myocardial oxygen consumption was altered during acute rejection of lung allografts. However, left ventricular contractility (systolic elastance, E max ) and ejection fraction were depressed to approximately one half ( P <.05) in acutely rejecting animals compared with other groups. The cross-sectional area of the coronary arteries was less in autotransplanted and allotransplanted treated animals than in animals that were not operated on. Cross-sectional area of the coronary arteries was decreased by an additional 30% in the rejecting group ( P <.05). Conclusions The results of this study indicate that acute rejection of a single lung allograft decreases cardiac performance and reduces diameter of coronary arteries in the recipient. Alterations of circulating humoral factors and activated leukocytes may contribute to these changes.
Quantitative Determination of Regional Left Ventricular Wall Dynamics by Roentgen Videometry
Dumesnil, Jean G., Ritman, Erik L., Frye, Robert L. , Gau, Gerald T., Rutherford, Barry D., Davis, George D.

Circulation | June 11, 2012 | Volume: 50 | Issue: 4 | Pages: 700-708

10.1161/01.cir.50.4.700 Get It

The use of roentgen videometry as a means of studying regional left ventricular wall dynamics and performance was evaluated in 32 patients undergoing coronary arteriography. Nine patients had normal coronary arteriograms and hemodynamic findings (group 1), 8 patients had generalized decrease in left ventricular contraction and abnormal hemodynamic findings (group 2), and 15 patients with coronary artery disease had regional wall dynamics abnormalities (group 3). Sixty-per-second determinations of wall thickness were performed in selected sites of the left ventricle. Measurements performed included end-diastolic wall thickness (EDTw), mean and peak rates of systolic wall thickening (m and p dTw/dt), and fractional systolic increase in wall thickness (ΔTw/EDTw). In patients with uniformly performing ventricles (groups 1 and 2), these parameters correlated well with other parameters of ventricular function. Best distinction between the "normal" group (group 1) and the "abnormal" group (group 2) was achieved when the rates of thickening (m and p dTw/dt) were utilized ( P < 0.001). In patients of group 3, three types of abnormal regional wall dynamics could be determined and quantified objectively: hypokinesia (decreased p dTw/dt), akinesia (p dTw/dt = 0), and dyskinesia (p dTw/dt < 0). The severity of the abnormality of the wall dynamics correlated well with the presence or absence of a previous infarction on the electrocardiogram, and the anatomic location was strongly correlated with the distribution and severity of coronary artery lesions within a given ventricle.
Cardiac Micro–Computed Tomography Imaging of the Aging Coronary Vasculature
Sangaralingham, S. Jeson , Ritman, Erik L., Ichiki, Tomoko , Scott, Christopher G. , Martín, Fernando L., Harders, Gerald E., Bellavia, Diego , Burnett, John C. , Sangaralingham, S. Jeson , McKie, Paul M. , Lerman, Amir , Scott, Christopher

Circulation: Cardiovascular Imaging | June 8, 2012 | Volume: 5 | Issue: 4 | Pages: 518-524

10.1161/circimaging.112.973057 Get It

Background— Alterations at the level of the coronary circulation with aging may play an important role in the evolution of age-associated changes in left ventricular (LV) fibrosis and function. However these age-associated changes in the coronary vasculature remain poorly defined primarily due to the lack of high resolution imaging technologies. The current study was designed to utilize cardiac micro–computed tomography (micro-CT) technology as a novel imaging strategy, to define the 3-dimensional coronary circulation in the young and aged heart and its relationship to LV fibrosis and function. Methods and Results— Young (2 months old; n=10) and aged (20 months old; n=10) Fischer rats underwent cardiac micro-CT imaging as well as echocardiography, blood pressure, and fibrosis analysis. Importantly, when indexed to LV mass, which increased with age, the total and intramyocardial vessel volumes were lower, whereas the epicardial vessel volume, with and without indexing to LV mass, was significantly higher in the aged hearts compared with the young hearts. Moreover, the aged hearts had a significantly lower percentage of intramyocardial vessel volume and a significantly higher percentage of epicardial vessel volume, when normalized to the total vessel volume, compared with the young hearts. Further, the aged hearts had significant LV fibrosis and mild LV dysfunction compared with the young hearts. Conclusions— This micro-CT imaging study reports the reduction in normalized intramyocardial vessel volume within the aged heart, in association with increased epicardial vessel volume, in the setting of increased LV fibrosis, and mild LV dysfunction.
Relationship between surface area of nonperfused myocardium and extravascular extraction of contrast agent following coronary microembolization
Malyar, Nasser , Lerman, Lilach O. , Gössl, Mario , Beighley, Patricia E., Ritman, Erik L.

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology | May 5, 2011 | Volume: 301 | Issue: 2 | Pages: R430-R437

10.1152/ajpregu.00428.2010 Get It

Myocardial microvascular permeability and coronary sinus concentration of muscle metabolites have been shown to increase after myocardial ischemia due to epicardial coronary artery occlusion and reperfusion. However, their association with coronary microembolization is not well defined. This study tested the hypothesis that acute coronary microembolization increases microvascular permeability in the porcine heart. The left anterior descending perfusion territories of 34 anesthetized pigs (32 ± 3 kg) were embolized with equal volumes of microspheres of one of three diameters (10, 30, or 100 μm) and at three different doses for each size. Electron beam computed tomography (EBCT) was used to assess in vivo, microvascular extraction of a nonionic contrast agent (an index of microvascular permeability) before and after microembolization with microspheres at baseline and during adenosine infusion. A high-resolution three-dimensional microcomputed tomography (micro-CT) scanner was subsequently used to obtain ex vivo, the volume and corresponding surface area of the embolized myocardial islands within the perfusion territories of the microembolized coronary artery. EBCT-derived microvascular extraction of contrast agent increased within minutes after coronary microembolization ( P < 0.001 vs. baseline and vs. control values). The increase in coronary microvascular permeability was highly correlated to the micro-CT-derived total surface area of the nonperfused myocardium ( r = 0.83, P < 0.001). In conclusion, myocardial extravascular accumulation of contrast agent is markedly increased after coronary microembolization and its magnitude is in proportion to the surface area of the interface between the nonperfused and perfused territories.
Current Status of Developments and Applications of Micro-CT
Ritman, Erik L.

Annual Review of Biomedical Engineering | March 2, 2011 | Volume: 13 | Issue: 1 | Pages: 531-552

10.1146/annurev-bioeng-071910-124717 Get It

Use of microscopic computed-tomography (micro-CT) scanning continues to grow in biomedical research. Laboratory-based micro-CT scanners, laboratory-based nano-CT scanners, and integrated micro-CT/SPECT and micro-CT/PET scanners are now manufactured for “turn-key” operation by a number of commercial vendors. In recent years a number of technical developments in X-ray sources and X-ray imaging arrays have broadened the utility of micro-CT. Of particular interest are photon-counting and energy-resolving detector arrays. These are being explored to maximize micro-CT image grayscale dynamic range and to further increase image contrast by utilizing the unique spectral attenuation characteristics of individual chemical elements. X-ray phase-shift images may increase contrast resolution and reduce radiation exposure. Although radiation exposure is becoming a concern with the drive for increased spatial and temporal resolution, especially for longitudinal studies, gated scans and limited scan-data-set reconstruction algorithms show great potential for keeping radiation exposure to a minimum.
Automation of Hessian-Based Tubularity Measure Response Function in 3D Biomedical Images
Dzyubak, O. P. , Ritman, Erik L.

International Journal of Biomedical Imaging | February 22, 2011 | Volume: 2011 | Issue: No issue available | Pages: 1-16

10.1155/2011/920401 Get It

The blood vessels and nerve trees consist of tubular objects interconnected into a complex tree- or web-like structure that has a range of structural scale 5 μm diameter capillaries to 3 cm aorta. This large-scale range presents two major problems; one is just making the measurements, and the other is the exponential increase of component numbers with decreasing scale. With the remarkable increase in the volume imaged by, and resolution of, modern day 3D imagers, it is almost impossible to make manual tracking of the complex multiscale parameters from those large image data sets. In addition, the manual tracking is quite subjective and unreliable. We propose a solution for automation of an adaptive nonsupervised system for tracking tubular objects based on multiscale framework and use of Hessian-based object shape detector incorporating National Library of Medicine Insight Segmentation and Registration Toolkit (ITK) image processing libraries.
A preliminary study of few-view image reconstruction of sparse objects in cone-beam micro-CT
Han, Xiao , Bian, Junguo, Eaker, Diane R., Ritman, Erik L., Sidky, Emil Y. , Pan, Xiaochuan

SPIE Proceedings | March 19, 2010 | Volume: 7622 | Issue: No issue available | Pages: 76222P

10.1117/12.845320 Get It

A super resolution technique for clinical multislice CT
Liu, Xin , Yu, Lifeng , Ritman, Erik L., Yu, Lifeng , Manduca, Armando , McCollough, Cynthia H.

SPIE Proceedings | March 18, 2010 | Volume: 7622 | Issue: No issue available | Pages: 76221Q

10.1117/12.844831 Get It

Validation of a Fluid–Structure Interaction Model of Solute Transport in Pores of Cyclically Deformed Tissue Scaffolds
Buijs, Jorn op den , Ritman, Erik L., Dragomir‐Daescu, Dan

Tissue Engineering Part C: Methods | February 5, 2010 | Volume: 16 | Issue: 5 | Pages: 1145-1156

10.1089/ten.tec.2009.0685 Get It

Convection induced by repetitive compression of porous tissue scaffolds enhances solute transport inside the scaffold. Our previous experiments have shown that pore size, shape, and orientation with respect to strain direction greatly influence loading-induced solute transport. The objective of this study was to develop a computational model of deformation-induced solute transport in porous tissue scaffolds, which included the pore geometry of the scaffold. This geometry consisted of a cubic scaffold with single channel in the middle of the scaffold, immersed in a fluid reservoir. Cylindrical pores with circular or elliptic cross section, and spheroid pores were modeled. The scaffold was cyclically compressed from one side, causing fluid motion and dispersion of solute inside the scaffold pore. Scaffold deformation was solved using the finite element method, and fluid flow and solute transport were solved using the finite volume method. The distortion of the scaffold–fluid interface was transferred as a boundary condition to the fluid flow solver. Both convection and diffusion were included in the computations. The solute transport rates in the different scaffold pore geometries agreed well with our previous experimental results obtained with X-ray microimaging. This model will be used to explore transport properties of a spectrum of novel scaffold designs.