The use of microcomputed tomography to study microvasculature in small rodents
Bentley, Michael D., Ortíz, M. Clara , Ritman, Erik L., Romero, J. Carlos

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology | March 3, 2015 | Volume: 282 | Issue: 5 | Pages: R1267-R1279

10.1152/ajpregu.00560.2001 Get It

Appropriate nephron function is dependent on the intrarenal arrangement of blood vessels. The preferred and primary means to study the architecture of intrarenal circulation has been by filling it with opaque substances such as india ink, radio-opaque contrast material, or various polymers for study by light or scanning electron microscopy. With such methodologies, superficial vessels may obscure deep vessels and little quantitative information may be obtained. Serial-section microtomy has not been practical because of problems relating to alignment and registration of adjacent sections, lost sections, and preparation time and effort. Microcomputed tomography (micro-CT) overcomes such limitations and provides a means to study the three-dimensional architecture of filled vessels within an intact rodent kidney and to obtain more quantitative information. As an example of micro-CT's capabilities, we review the use of micro-CT to study the alterations in renal microvasculature caused by the development of liver cirrhosis after chronic bile duct ligation. In this example, micro-CT evidence shows a selective decrease in cortical vascular filling in the kidney, with a maintenance of medullary vascular filling. These changes may contribute to the salt and water retention that accompanies cirrhosis. These results indicate that micro-CT is a promising method to evaluate renal vascular architecture in the intact rodent kidney relative to physiological and pathological function.
Earl Wood–A research career noted for development of novel instruments driven by the power of the indicator dilution concept
Ritman, Erik L.

Journal of Applied Physiology | September 5, 2014 | Volume: 117 | Issue: 9 | Pages: 945-956

10.1152/japplphysiol.00491.2014 Get It

During World War 2, Earl Wood was charged with elucidating the biomedical factors in acceleration-induced loss of consciousness experienced by pilots in high-performance aircraft. For this, he developed devices for measurement and recording of blood pressure and tissue blood content. Those data lead to the design and fabrication of successful countermeasures to acceleration-induced loss of consciousness with an inflatable “G-suit” and “M1” breath-holding maneuver. After World War 2, he utilized and modified these instruments and made use of indicator dilution techniques by continuous intracardiac blood sampling to greatly increase the specificity and sensitivity of diagnosis of intracardiac anatomic and functional abnormalities in patients with congenital heart disease. This contributed to the greatly increased success rate of open-heart surgery in the 1950s. In the 1960s, he built on the then recently available video-coupled electronic X-ray image intensifier to develop X-ray fluoroscopy-based recording of indicator dilution signals in all cardiac chambers and surrounding great vessels without the need for placing catheter tips at those locations for blood sampling. However, these blood flow-related data were of limited value, as they were not measured concurrent with myocardial functional demand for perfusion. In the 1970s, he overcame this limitation by developing a high-speed multislice X-ray imaging scanner to provide tomographic images of concurrent dynamic cardiac anatomy and the indicator dilution-based estimates of blood flow distributions. On his retirement at age 70 in 1982, he had accomplished his 2 decade-old goal of the ability to make accurate concurrent, minimally invasive, and indicator dilution-based measurement of cardiovascular structure to function relationships.
Anatomy of hepatic arteriolo‐portal venular shunts evaluated by 3D micro‐CT imaging
Kline, Timothy L. , Anderson, Jill , Vercnocke, Andrew J. , Jorgensen, Steven M., Ritman, Erik L., Knudsen, Bruce E.

Journal of Anatomy | March 31, 2014 | Volume: 224 | Issue: 6 | Pages: 724-731

10.1111/joa.12178 Get It

AbstractThe liver differs from other organs in that two vascular systems deliver its blood – the hepatic artery and the portal vein. However, how the two systems interact is not fully understood. We therefore studied the microvascular geometry of rat liver hepatic artery and portal vein injected with the contrast polymer Microfil®. Intact isolated rat livers were imaged by micro‐CT and anatomic evidence for hepatic arteriolo‐portal venular shunts occurring between hepatic artery and portal vein branches was found. Simulations were performed to rule out the possibility of the observed shunts being artifacts resulting from image blurring. In addition, in the case of specimens where only the portal vein was injected, only the portal vein was opacified, whereas in hepatic artery injections, both the hepatic artery and portal vein were opacified. We conclude that mixing of the hepatic artery and portal vein blood can occur proximal to the sinusoidal level, and that the hepatic arteriolo‐portal venular shunts may function as a one‐way valve‐like mechanism, allowing flow only from the hepatic artery to the portal vein (and not the other way around).
Quantitative 3D Micro-CT Imaging of Human Lung Tissue
Kampschulte, Marian, Litzlbauer, H., Tscholl, Dietmar, Zeiner, Carsten , Krombach, Gabriele A. , Ritman, Erik L., Bohle, Rainer M., Langheinrich, Alexander C., Schneider, C.

RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren | September 2, 2013 | Volume: 185 | Issue: 09 | Pages: 869-876

10.1055/s-0033-1355498 Get It

Quantitative 3D Micro-CT Imaging of Human Lung Tissue
Kampschulte, Marian, Litzlbauer, H., Tscholl, Dietmar, Zeiner, Carsten , Krombach, Gabriele A. , Ritman, Erik L., Bohle, Rainer M., Langheinirch, A., Schneider, C. , Langheinirch, A.

RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren | July 25, 2013 | Volume: 185 | Issue: 09 | Pages: 869-876

10.1055/s-0033-1350105 Get It

Intrinsic microvasculature of the sciatic nerve in the rat
Zamir, M. , Twynstra, Jasna , Vercnocke, Andrew J. , Welch, Ian, Jorgensen, Steve M., Ritman, Erik L., Holdsworth, David W. , Shoemaker, J. Kevin , Jorgensen, Steven M., Shoemaker, J Kevin

Journal of the Peripheral Nervous System | December 22, 2012 | Volume: 17 | Issue: 4 | Pages: 377-384

10.1111/j.1529-8027.2012.00435.x Get It

AbstractMicrovasculature associated with the sciatic nerve was examined using high‐resolution micro‐CT scanning in one group of rats and surgical exploration in another. The results indicate that blood supply to the sciatic nerve is an “open‐ended” system in which the vessels run longitudinally within the epineurium and connect with external vasculature primarily at junction points. Although the range of vasculature found extended down to 4–5 μ, only a few isolated vessels of this size were found, with no capillary “mesh” as such, possibly because of the close proximity of the intrinsic vessel to nerve fibers within the epineurium. While the study did not include direct measurements of flow or nerve function, the “open‐ended” pattern of vasculature found has important implications regarding the relationship between the two. Specifically, the nerve is less vulnerable to a severe or complete disruption in blood supply than it would be under a close‐ended system such as that of the heart or brain, where a severe disruption can occur with the obstruction of only a single vessel. Indeed, the pattern of vasculature found, subject to further study of vasculature at the capillary level, suggests that flow within the intrinsic vessels may be in either direction, depending on circumstances, somewhat like flow within the circle of Willis in the cerebral circulation.
Vascularity of myocardium and gastrocnemius muscle in rats selectively bred for endurance running capacity
Beighley, Patricia E., Zamir, M. , Wentz, Robert J., Koch, Lauren G. , Britton, Steven L. , Ritman, Erik L.

Physiological Genomics | December 11, 2012 | Volume: 45 | Issue: 3 | Pages: 119-125

10.1152/physiolgenomics.00110.2012 Get It

We tested the hypothesis that changes in the arteriolar branching architecture contributed to increased running capacity of rats subjected to two-way artificial selection for intrinsic aerobic endurance treadmill running capacity resulting in strains of low-capacity and high-capacity endurance rats. Hearts and gastrocnemius muscles were harvested from each strain, and the microvasculature's branching geometry measured from micro-CT images. The vascular branching geometry of the hearts and skeletal muscle from the high capacity was indistinguishable from low-capacity rats. Our hypothesis was not supported. Neither remodeling nor an increase in arteriolar microvasculature branching appears to play a role in the enhanced performance of the high capacity rats. We are led to speculate that endothelial tolerance for shear stress and/or increased coupling of myocardial muscle fiber metabolic-to-contractile function is increased in the high-capacity runner strain to the effect of allowing either higher flow rate per unit volume of muscle or more efficient use of oxygen and nutrients in the high-capacity endurance rats.
In vivoDrosophiliagenetic model for calcium oxalate nephrolithiasis
Hirata, Taku, Cabrero, Pablo , Berkholz, Donald S., Bondeson, Daniel P. , Ritman, Erik L., Thompson, James R. , Dow, Julian A. T. , Romero, Michael F. , Dow, Julian A T , Romero, Michael F

American Journal of Physiology-Renal Physiology | September 20, 2012 | Volume: 303 | Issue: 11 | Pages: F1555-F1562

10.1152/ajprenal.00074.2012 Get It

Nephrolithiasis is a major public health problem with a complex and varied etiology. Most stones are composed of calcium oxalate (CaOx), with dietary excess a risk factor. Because of complexity of mammalian system, the details of stone formation remain to be understood. Here we have developed a nephrolithiasis model using the genetic model Drosophila melanogaster, which has a simple, transparent kidney tubule. Drosophilia reliably develops CaOx stones upon dietary oxalate supplementation, and the nucleation and growth of microliths can be viewed in real time. The Slc26 anion transporter dPrestin (Slc26a5/6) is strongly expressed in Drosophilia kidney, and biophysical analysis shows that it is a potent oxalate transporter. When dPrestin is knocked down by RNAi in fly kidney, formation of microliths is reduced, identifying dPrestin as a key player in oxalate excretion. CaOx stone formation is an ancient conserved process across >400 My of divergent evolution (fly and human), and from this study we can conclude that the fly is a good genetic model of nephrolithiasis.
Three-Dimensional Microcomputed Tomography of Renal Vasculature in Rats
Garcia-Sanz, A., Rodríguez‐Barbero, Alicia , Bentley, Michael D., Ritman, Erik L., Romero, J. Carlos

Hypertension | June 12, 2012 | Volume: 31 | Issue: 1 | Pages: 440-444

10.1161/01.hyp.31.1.440 Get It

Current microscopic methods to view renal microvasculature reveal only a very limited portion of the total renal volume. Identification of connectivity for postglomerular vessels in the cortex and the medulla during functional states related to changes in sodium excretion will help better to understand the coupling of renal vasculature to tubular function. The purpose of this study was to investigate the possibility of visualizing the continuity of pre- and postglomerular vasculature using three-dimensional micro-computed tomography (micro-CT). Kidneys from normal rats were perfusion fixed in situ at physiological pressure, filled with latex microfil containing lead chromate, and embedded in plastic. The micro-CT scans of the intact kidneys were carried out on a rotating stage illuminated either by a synchrotron x-ray source or a conventional x-ray spectroscopy tube. Images were reconstructed by a filtered backprojection algorithm and volume-rendering techniques were utilized to display the vasculature. The reconstructed images clearly showed the large distribution vessels and the venous drainage of the kidneys, while pre- and postglomerular vessels and their vascular connections throughout the kidney were displayed in great detail. Efferent arterioles showed the characteristics of their peritubular capillary beds in the cortical and medullary regions. The vascular volume of the cortex was 27%, the outer stripe of the outer medulla 18%, the inner stripe of the outer medulla 30%, and the inner medulla 18%. In conclusion, micro-CT is a promising method to evaluate renal vascular architecture relative to physiological and pathological alterations.
Minimally Invasive Evaluation of Coronary Microvascular Function by Electron Beam Computed Tomography
Möhlenkamp, Stefan, Lerman, Lilach O. , Behrenbeck, Thomas, Katušić, Zvonimir S. , Sheedy, Patrick F. , Ritman, Erik L., Lerman, Amir

Circulation | June 12, 2012 | Volume: 102 | Issue: 19 | Pages: 2411-2416

10.1161/01.cir.102.19.2411 Get It

Background —We previously demonstrated that in vivo electron-beam computed tomography (EBCT)–based indicator-dilution methods provide an estimate of intramyocardial blood volume (BV) and perfusion (F), which relate as BV=aF+b√F, where a characterizes the recruitable (exchange) and b the nonrecruitable (conduit) component of the myocardial microcirculation. In the present study, we compared BV and F with intracoronary Doppler ultrasound–based coronary blood flow (CBF) as a method for detecting and quantifying differential responses of these microvascular components to vasoactive drugs in normal (control) and hypercholesterolemic (HC) pigs. Methods and Results —BV and F values were obtained from contrast-enhanced EBCT studies in 14 HC and 14 control pigs. BV, F, and CBF values were obtained at baseline (intracoronary infusion of saline) and after 5 minutes each of intracoronary infusion of adenosine (100 μg · kg − 1 · min − 1 ) and nitroglycerin (40 μg/min). BV and CBF reserves in response to adenosine were attenuated in HC pigs compared with controls (90±36% versus 127±42%, P <0.03, and 485±182% versus 688±160%, P <0.01, respectively). The relationship between BV and F showed consistently lower recruitable BV in HC versus control pigs. Nonrecruitable BV reserve in response to adenosine was attenuated in HC compared with controls (77±20% versus 135±28%, P <0.001). Our findings are consistent with HC-induced impairment of intramyocardial resistance vessel function. Conclusions —EBCT technology allows minimally invasive evaluation of intramyocardial microcirculatory function and permits assessment of microvascular BV distribution in different functional components. This method may be of value in evaluating the coronary microcirculation in pathophysiological states such as hypercholesterolemia.