Purpose To describe injury epidemiology in U.S. adolescent tennis players between 2014 and 2018 via the High School Reporting Information Online (HS RIO) database. Methods The HS RIO database was queried for injury data on high school tennis players as reported by athletic trainers between 2014 and 2018. Injuries were analyzed according to athlete demographics, injury type, location, and context. Variables of interest between male and female athletes were compared using Pearson χ 2 test or Fisher exact test. Results In total, 176 injuries in high school tennis players between 2014 and 2018 were identified in the HS RIO database. Overall, 25.6% (45/176) occurred in the ankle, 12.5% (22/176) in the knee, and 9.7% (17/176) in the wrist. The most common types of injuries were ligament sprains and muscle strains at 35.2% (62/176) and 17.6% (31/176) of injuries, respectively. Although most injuries were unrelated to contact, such as overuse and heat exertion or stroke, 28.7% (47/176) of injuries were the result of rotation around a planted foot/inversion of the foot. We found no difference in injury patterns between male and female high school tennis athletes. Conclusions We found no difference in injury patterns between male and female U.S. high school tennis athletes. The ankles, knees, and wrists were the most commonly injured areas in this population. The most common types of injuries were ligament sprains and muscle strains. Although many injuries were new, athletes rarely required surgery and returned to play. Finally, we found no difference in injury patterns between male and female high school tennis athletes. Clinical Relevance The epidemiology of injuries among high school tennis players is poorly understood. The information from this study will help us to understand these injuries and how we may be able to better prevent them.
Carbon fiber–reinforced PEEK instrumentation in the spinal oncology population: a retrospective series demonstrating technique, feasibility, and clinical outcomes
OBJECTIVE The authors aimed to demonstrate the feasibility and advantages of carbon fiber–reinforced PEEK (CFRP) composite implants in patients with both primary and secondary osseous spinal tumors. METHODS Twenty-eight spinal tumor patients who underwent fixation with CFRP hardware were retrospectively identified in a Spine Tumor Quality Database at a single institution. Demographic, procedural, and follow-up data were retrospectively collected. RESULTS The study population included 14 females and 14 males with a mean age of 60 years (range 30–86 years). Five patients had primary bone tumors, and the remaining patients had metastatic tumors. Breast cancer was the most common metastatic tumor. The most common presenting symptom was axial spine pain (25 patients, 89%), and the most common Spine Instability Neoplastic Score was 7 (range 6–14). Two patients in this series had anterior cervical procedures. The remaining patients underwent posterior thoracolumbar fixation. The average fusion length included 4.6 vertebral segments (range 3–8). The mean clinical follow-up time with surgical or oncology teams was 6.5 months (range 1–23 months), and the mean interval for last follow-up imaging (CT or MRI) was 6.5 months (range 1–22 months). Eighteen patients received postoperative radiation at the authors’ institution (16 with photon therapy, 2 with proton therapy). Eleven of the patients (39%) in this series died. At the last clinical follow-up, 26 patients (93%) had stable or improved neurological function compared with their preoperative status. At the last imaging follow-up, local disease control was observed in 25 patients (89%). Two patients required reoperation in the immediate postoperative period, one for surgical site infection and the other for compressive epidural hematoma. One patient was noted to have lucencies around the most cephalad screws 3 months after surgery. No hardware fracture or malfunction occurred intraoperatively. No patients required delayed surgery for hardware loosening, fracture, or other failure. Early tumor recurrence was detected in 3 patients. Early detection was attributed to the imaging characteristics of the CFRP hardware. CONCLUSIONS CFRP spinal implants appear to be safe and comparable to conventional titanium implants in terms of functionality. The imaging characteristics of CFRP hardware facilitate radiation planning and assessment of surveillance imaging. CFRP hardware may enhance safety and efficacy, particularly with particle therapy dosimetry. Larger patient populations with longer-term follow-up are needed to confirm the various valuable aspects of CFRP spinal implants.
Spinal intramedullary hemangioblastoma and schwannoma collision tumor: illustrative case
BACKGROUND Intramedullary spinal cord tumors represent a minority of intradural tumors. Among intramedullary spinal cord tumors, hemangioblastomas are uncommon, and schwannomas are extremely rare. Collision tumors are histologically distinct tumors that are intermingled and growing together. OBSERVATIONS In this report, the authors describe a patient with a cervical intramedullary collision tumor involving a hemangioblastoma and schwannoma. To the authors’ knowledge, no prior spinal intramedullary collision tumor involving multiple neoplasms has been described. The patient’s presentation and management are described. LESSONS Clinicians should consider the possibility of collision tumors when evaluating intramedullary spinal cord tumors, especially when patient presentation and radiographic findings are atypical. When tumors with similar radiographic characteristics form collision tumors, distinction using preoperative imaging can be extremely challenging. In addition, surgical management of intramedullary collision tumors, like that for all intramedullary spinal cord tumors, should involve meticulous perioperative care and a methodical surgical technique. Maximal safe resection will depend upon histopathological diagnosis, anatomical location of the tumor, presence of distinct dissection planes, and stability of neuromonitoring. Finally, ongoing research on the genetics of intramedullary spinal cord tumors may identify underlying genetic links for intramedullary hemangioblastomas and schwannomas.
An unusual case of a persistent, infected retroperitoneal fluid collection 5 years after anterior lumbar fusion surgery: illustrative case
BACKGROUND Anterior lumbar fusion procedures have many benefits and continue to grow in popularity. The technique has many potential approach- and procedure-related complications. Symptomatic retroperitoneal fluid collections are uncommon but potentially serious complications after anterior lumbar procedures. Collection types include hematomas, urinomas, chyloperitoneum, cerebrospinal fluid collections, and deep infections. OBSERVATIONS The authors present an unusual case of a patient with persistent symptoms related to a retroperitoneal collection over a 5-year period following anterior lumbar fusion surgery. To the authors’ knowledge, no similar case with such extensive symptom duration has been described. The patient had an infected encapsulated fluid collection. The collection was presumed to be a postoperative lymphocele that was secondarily infected after serial percutaneous drainage procedures. LESSONS When retroperitoneal collections occur after anterior retroperitoneal approaches, clinical clues, such as timing of symptoms, hypotension, acute anemia, urinary tract infection, hydronephrosis, elevated serum creatinine and blood urea nitrogen, low-pressure headaches, anorexia, or systemic signs of infection, can help narrow the differential. Retroperitoneal collections may continue to be symptomatic many years after anterior lumbar surgery. The collections may become infected after serial percutaneous drainage or prolonged continuous drainage. Encapsulated, infected fluid collections typically require surgical debridement of the capsule and its contents.