Citations 2

HER-2 Fluorescence In Situ Hybridization: Results From the Survey Program of the College of American Pathologists
Persons, Diane L., Tubbs, Raymond R., Cooley, Linda D. , Dewald, Gordon W., Dowling, Patricia K., Du, Emma, Mascarello, James T., Rao, Kathleen W., Wolff, Daynna J., Habegger-Vance, Gail, Wilson, Kathleen S.

Archives of Pathology & Laboratory Medicine | February 11, 2021 | Volume: 130 | Issue: 3 | Pages: 325-331

10.5858/2006-130-325-hfishr Get It

Abstract Context. —Fluorescence in situ hybridization (FISH) is a common method used to determine HER-2 status in breast cancer. Limited information is available concerning reproducibility of FISH in determining HER-2 gene amplification. Objective. —To present proficiency testing results of FISH for HER-2 conducted by the Cytogenetics Resource Committee of the College of American Pathologists/American College of Medical Genetics. Design. —During the past 5 years, unstained sections from 9 invasive breast carcinomas were used for HER-2 FISH proficiency testing, allowing for comparison of FISH results among a large number of laboratories. Additional data were collected using an educational (ungraded) challenge and supplemental questions in the surveys. Results. —The number of laboratories participating in HER-2 FISH proficiency testing has increased steadily during the past 5 years (from 35 in 2000 to 139 in 2004). Reproducibility of test results among laboratories was excellent for breast tumors with low copy number (no HER-2 amplification) and for breast tumors with high copy number ( HER-2 amplification). However, there was considerable variation in interpretation of results for a tumor with low-level HER-2 amplification that was tested on 2 separate occasions. Responses to supplemental questions indicated that there was a need for consensus on the use of a separate equivocal/borderline interpretative category and the need for standardization of cutoff values used to define interpretative categories. Conclusions. —The College of American Pathologists proficiency survey programs provide useful information concerning the reproducibility of clinical testing for HER-2 by FISH and reflect clinical interpretation of HER-2 FISH analyses from laboratories across the country.
Proficiency Testing for Laboratories Performing Fluorescence In Situ Hybridization With Chromosome-Specific DNA Probes
Mascarello, James T., Brothman, Arthur R., Davison, Keri, Dewald, Gordon W., Herrman, Marille, McCandless, Danette, Park, Jonathan P., Persons, Diane L., Rao, Kathleen W., Schneider, Nancy R., Vance, Gail H. , Cooley, Linda D.

Archives of Pathology & Laboratory Medicine | January 29, 2021 | Volume: 126 | Issue: 12 | Pages: 1458-1462

10.5858/2002-126-1458-ptflpf Get It

Abstract Objective.—To assess laboratory performance, use, and limitations in the joint College of American Pathologists and American College of Medical Genetics proficiency testing program for laboratories performing cytogenetic tests based on fluorescence in situ hybridization (FISH). Data Sources.—Eight proficiency surveys dealing with FISH detection of microdeletions or microduplications, aneuploidy in interphase cells, gene amplification, and neoplasm-specific translocations. Participating laboratories used their own DNA probes (commercial or home-brew), hybridization methods, and analytic criteria to answer clinical questions about cases represented by slides included in the survey materials. They also described their test results according to the International System for Human Cytogenetic Nomenclature (ISCN) and answered supplementary questions relating to their experience with the subject test systems. Data Extraction.—In addition to evaluating diagnostic accuracy, we evaluated survey use, laboratory experience, variation in methodologic approach, and the practicality of using ISCN nomenclature for describing test results. Synthesis and Conclusions.—With the exception of one challenge, at least 80% of the participants reached the correct diagnostic conclusion. In the sole exception, there was still a consensus of 91.7% of participants with the same (albeit erroneous) diagnostic conclusion. The overall outstanding performance of participating laboratories clearly shows the reliability of current FISH methods. Despite the fact that a large number of laboratories reported little or no experience with the specific test systems, the overwhelming majority performed very well. This result shows that the program's strategy of targeting classes of abnormalities (vs a single abnormality associated with a specific disease) did not put at a disadvantage participants who did not routinely perform all of the potential tests in the class. The extraordinary variation in ISCN descriptions submitted by participants showed that the existing system for human cytogenetic nomenclature is not suitable for facile communication of FISH test results.