BACKGROUND: Delayed hypopituitarism is the most common complication after stereotactic radiosurgery (SRS) for pituitary adenomas. OBJECTIVE: To investigate the relationship between neuroanatomic structure distances from the radiation target and anterior pituitary function preservation after SRS through multicenter study. METHODS: We retrospectively reviewed the International Radiosurgery Research Foundation database from January 2002 to December 2021 for adult patients undergoing SRS for pituitary adenomas with >6 months of follow-up. Distances between centers or edges of hypothalamic-pituitary axis structures and SRS target volumes were measured using MRI. The primary outcome was anterior pituitary function preservation. Predictors were analyzed using multivariable logistic regression and area under the receiver operating curve (AUROC) curve analyses. RESULTS: Four hundred eighty-seven patients were categorized by preservation (n = 384) and no preservation (n = 103) of anterior pituitary function. The mean margin dose was 19.1(6.2) Gy. Larger distance from the center of the stalk to the tumor margin isodose was a positive predictor (adjusted odds ratio [aOR] = 1.162 [1.046-1.291], P = .005), while pre-SRS hypopituitarism (aOR = 0.646 [0.405-1.031], P = .067) and larger treatment volume (aOR = 0.965 [0.929-1.002], P = .061) were near negative predictors of the primary outcome. An interaction between the treatment volume and center stalk to margin isodose distance was found (aOR = 0.980 [0.961-0.999], P = .045). Center stalk to margin isodose distance had an AUROC of 0.620 (0.557-0.693), at 3.95-mm distance. For patients with treatment volumes of <2.34 mL, center stalk to margin isodose distance had an AUROC of 0.719 (0.614-0.823), at 2.95-mm distance. CONCLUSION: Achieving a distance between the center of the pituitary stalk and the tumor margin isodose ≥3.95 mm predicted anterior pituitary function preservation. For smaller treatment volumes <2.34 mL, the optimal distance was ≥2.95 mm. This may be modifiable during trans-sphenoidal resection to preserve pituitary function.
Proton and Heavy Particle Intracranial Radiosurgery
Stereotactic radiosurgery (SRS) involves the delivery of a highly conformal ablative dose of radiation to both benign and malignant targets. This has traditionally been accomplished in a single fraction; however, fractionated approaches involving five or fewer treatments have been delivered for larger lesions, as well as lesions in close proximity to radiosensitive structures. The clinical utilization of SRS has overwhelmingly involved photon-based sources via dedicated radiosurgery platforms (e.g., Gamma Knife® and Cyberknife®) or specialized linear accelerators. While photon-based methods have been shown to be highly effective, advancements are sought for improved dose precision, treatment duration, and radiobiologic effect, among others, particularly in the setting of repeat irradiation. Particle-based techniques (e.g., protons and carbon ions) may improve many of these shortcomings. Specifically, the presence of a Bragg Peak with particle therapy at target depth allows for marked minimization of distal dose delivery, thus mitigating the risk of toxicity to organs at risk. Carbon ions also exhibit a higher linear energy transfer than photons and protons, allowing for greater relative biological effectiveness. While the data are limited, utilization of proton radiosurgery in the setting of brain metastases has been shown to demonstrate 1-year local control rates >90%, which are comparable to that of photon-based radiosurgery. Prospective studies are needed to further validate the safety and efficacy of this treatment modality. We aim to provide a comprehensive overview of clinical evidence in the use of particle therapy-based radiosurgery.