Back to Authors

Pritt, Bobbi S.

https://orcid.org/0000-0003-0261-1326

Mayo Clinic

Mayo Clinic

Citations 143

Photo Quiz: A 54-Year-Old Male with Acute Myelogenous Leukemia Presenting with Right Periorbital Swelling and Diplopia
Ramanan, Poornima , Wengenack, Nancy L. , Pritt, Bobbi S. , Pritt, Bobbi S

Journal of Clinical Microbiology | January 28, 2016 | Volume: 54 | Issue: 2 | Pages: 249-249

10.1128/jcm.00375-14 Get It

Superantigen-Producing Staphylococcus aureus Elicits Systemic Immune Activation in a Murine Wound Colonization Model
Kim, Choon Kwan , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Tilahun, Ashenafi Y. , Krogman, Ashton , David, Chella S., Pritt, Bobbi S. , Patel, Robin , Rajagopalan, Govindarajan , Kim, Choon K, Patel, Robin , Pritt, Bobbi S

Toxins | December 9, 2015 | Volume: 7 | Issue: 12 | Pages: 5308-5319

10.3390/toxins7124886 Get It

Staphylococcus aureus, the most common cause of wound infection, produces several exotoxins, including superantigens (SAgs). SAgs are the potent activators of the immune system. Given this unique property, we hypothesized that SAgs produced by S. aureus in wounds would have local, as well as systemic immunologic effects. We tested our hypothesis using a novel staphylococcal skin wound infection model in transgenic mice expressing HLA-DR3. Skin wounds were left uninfected or colonized with S. aureus strains producing SAgs or an isogenic strain not producing any SAg. Animals with wounds challenged with SAg-producing S. aureus had increased morbidity and lower serum IL-17 levels compared to those challenged with the SAg non-producing S. aureus (p = 0.027 and p = 0.032, respectively). At Day 8 following microbial challenge, compared to mice with uninfected wounds, the proportion of Vβ8+CD4+ T cells was increased, while the proportion of Vβ8+CD8+ T cells was decreased only in the spleens of mice challenged with SAg-producing S. aureus (p < 0.001). No such changes were measured in mice challenged with SAg non-producing S. aureus. Lungs, livers and kidneys from mice challenged with SAg-producing, but not SAg non-producing, S. aureus showed inflammatory changes. Overall, SAg-mediated systemic immune activation in wounds harboring S. aureus may have clinical implications.
Adolescent With Lymphadenopathy in the Absence of Systemic Symptoms
Bidadi, Behzad, Uzodi, Adaora S. , Pritt, Bobbi S. , Khan, Shakila P. , Henry, Nancy K., Pritt, Bobbi S

Clinical Pediatrics | March 2, 2015 | Volume: 54 | Issue: 12 | Pages: 1221-1223

10.1177/0009922815574082 Get It

A Five-Year-Old Child with a Subcutaneous Forehead Nodule
Westblade, Lars F. , Fischer, Peter , Haghi, Nina, Schniederjan, Matthew , Pritt, Bobbi S. , Long, John G., Jerris, Robert C. , Garola, Robert E., Pritt, Bobbi S

Pediatric and Developmental Pathology | January 8, 2015 | Volume: 18 | Issue: 2 | Pages: 164-166

10.2350/14-08-1545-cr.1 Get It

We describe a case of a 5-year-old girl with onchocerciasis. The patient was recently adopted from Ethiopia and presented with a firm, raised nodule on the midportion of the forehead. Initially, Langerhans cell histiocytosis with bone involvement was suspected; however, histopathologic analysis of the excised nodule revealed the presence of a young-adult, female Onchocerca volvulus worm. This case exemplifies the importance of recognizing the key morphologic characteristics of adult O. volvulus worms isolated from pediatric patients in nonendemic areas to ensure adroit clinical management.
Equal Performance of Self-Collected and Health Care Worker-Collected Pharyngeal Swabs for Group A Streptococcus Testing by PCR
Murray, Martha A. , Schulz, Lorie A., Furst, Joseph W. , Homme, Jason H. , Jenkins, Sarah M. , Uhl, James R., Patel, Robin , Cockerill, Franklin C., Myers, Jane F., Pritt, Bobbi S. , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | December 10, 2014 | Volume: 53 | Issue: 2 | Pages: 573-578

10.1128/jcm.02500-14 Get It

ABSTRACT A process employing patient- or parent-collected pharyngeal swabs for group A Streptococcus (GAS) testing would expedite diagnosis and treatment, reduce patient exposure to the health care setting, and decrease health care costs. Our aim was to determine the concordance between patient- or parent-collected (self-collected) and health care worker (HCW)-collected pharyngeal swabs for detection of GAS by PCR. From 9 October 2012 to 21 March 2013, patients presenting with a sore throat meeting criteria for GAS testing and not meeting criteria for severe disease were offered the opportunity to collect their own pharyngeal swab. The HCW also collected a swab. Paired swabs were tested by GAS real-time PCR, allowing semiquantitative comparisons between positive results. Of the 402 participants, 206 had a swab collected by the patient and 196 a swab collected by the parent. The percent positivity results were 33.3% for HCW-collected swabs and 34.3% for self-collected swabs ( P = 0.41). The overall concordance between the two collection strategies was 94.0% (95% confidence interval [CI], 91.3 to 96.0). Twenty-four of the paired swabs had discordant results, with 10 and 14 positives detected only with the HCW- and self-collected swabs, respectively ( P = 0.41). The person collecting the swab in the self-collected arm, the order of collection, and prior swab collection training did not influence results. Among the 124 specimens that were positive by both collection methods, the amount of GAS DNA was higher in the self-collected versus the HCW-collected swabs ( P = 0.008). Self-collected pharyngeal swabs provide a reliable alternative to HCW collection for detection of GAS and offer a strategy for improved health care delivery.
First Reported Case of Ehrlichia ewingii Involving Human Bone Marrow
Allen, Mr, Pritt, Bobbi S. , Sloan, Lynne M., Paddock, Christopher D. , Musham, Chaitanya K., Ramos, Jeanette M., Cetin, Neslihan, Rosenbaum, Eric , Pritt, Bobbi S

Journal of Clinical Microbiology | September 4, 2014 | Volume: 52 | Issue: 11 | Pages: 4102-4104

10.1128/jcm.01670-14 Get It

ABSTRACT A 65-year-old female with a history of multiple tick bites presented with fever and pancytopenia. Intracytoplasmic rickettsial morulae were detected on peripheral smear and bone marrow biopsy specimens, and PCR amplified Ehrlichia ewingii DNA from both specimens. To our knowledge, this is the first report of E. ewingii infection of human bone marrow.
Comparative Evaluation of Three Commercial Systems for Detection of High-Risk Human Papillomavirus in Cervical and Vaginal ThinPrep PreservCyt Samples and Correlation with Biopsy Results
Binnicker, Matthew J. , Pritt, Bobbi S. , Duresko, Brian J., Espy, Mark J., Grys, Thomas E. , Zarka, Matthew A., Kerr, Sarah E. , Henry, Michael , Pritt, Bobbi S , Grys, Thomas E

Journal of Clinical Microbiology | August 14, 2014 | Volume: 52 | Issue: 10 | Pages: 3763-3768

10.1128/jcm.01928-14 Get It

ABSTRACT Genital human papillomavirus (HPV) is the etiologic agent of more than 99% of all cervical cancers worldwide, with 14 genotypes being considered oncogenic or “high risk” because of their association with severe dysplasia and cervical carcinoma. Among these 14 high-risk types, HPV-16 and -18 account for approximately 70% of cervical cancers. The aim of this study was to evaluate three FDA-approved HPV nucleic acid-based tests for the ability to predict high-grade cervical intraepithelial neoplasias (CIN2 or worse) in corresponding tissue biopsy specimens. Residual specimens (total n = 793, cervical n = 743, vaginal n = 50) collected in ThinPrep PreservCyt medium with a cytologic result of ≥atypical squamous cells of undetermined significance were tested by the Hybrid Capture 2 (HC2) assay (Qiagen, Gaithersburg, MD), the cobas HPV test (Roche Diagnostics, Indianapolis, IN), and the APTIMA HPV assay (Hologic, San Diego, CA). Genotyping for HPV-16 and HPV-18 was simultaneously performed by the cobas HPV test. Results were compared to cervical or vaginal biopsy findings, when they were available ( n = 350). Among the 350 patients with corresponding biopsy results, 81 (23.1%) showed ≥CIN2 by histopathology. The ≥CIN2 detection sensitivity was 91.4% by the cobas and APTIMA assays and 97.5% by HC2 assay. The specificities of the cobas, APTIMA, and HC2 assays were 31.2, 42.0, and 27.1%, respectively. When considering only positive HPV-16 and/or HPV-18 genotype results, the cobas test showed a sensitivity and a specificity of 51.9 and 86.6%, respectively. While the HC2, cobas, and APTIMA assays showed similar sensitivities for the detection of ≥CIN2 lesions, the specificities of the three tests varied, with the greatest specificity (86.6%) observed when the HPV-16 and/or HPV-18 genotypes were detected.
Comparative Evaluation of Two Commercial Multiplex Panels for Detection of Gastrointestinal Pathogens by Use of Clinical Stool Specimens
Khare, Reeti , Espy, Mark J., Cebelinski, Elizabeth , Boxrud, David, Sloan, Lynne M., Cunningham, Scott A. , Pritt, Bobbi S. , Patel, Robin , Binnicker, Matthew J. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | August 7, 2014 | Volume: 52 | Issue: 10 | Pages: 3667-3673

10.1128/jcm.01637-14 Get It

ABSTRACT The detection of pathogens associated with gastrointestinal disease may be important in certain patient populations, such as immunocompromised hosts, the critically ill, or individuals with prolonged disease that is refractory to treatment. In this study, we evaluated two commercially available multiplex panels (the FilmArray gastrointestinal [GI] panel [BioFire Diagnostics, Salt Lake City, UT] and the Luminex xTag gastrointestinal pathogen panel [GPP] [Luminex Corporation, Toronto, Canada]) using Cary-Blair stool samples ( n = 500) submitted to our laboratory for routine GI testing (e.g., culture, antigen testing, microscopy, and individual real-time PCR). At the time of this study, the prototype (non-FDA-cleared) FilmArray GI panel targeted 23 pathogens (14 bacterial, 5 viral, and 4 parasitic), and testing of 200 μl of Cary-Blair stool was recommended. In contrast, the Luminex GPP assay was FDA cleared for the detection of 11 pathogens (7 bacterial, 2 viral, and 2 parasitic), but had the capacity to identify 4 additional pathogens using a research-use-only protocol. Importantly, the Luminex assay was FDA cleared for 100 μl raw stool; however, 100 μl Cary-Blair stool was tested by the Luminex assay in this study. Among 230 prospectively collected samples, routine testing was positive for one or more GI pathogens in 19 (8.3%) samples, compared to 76 (33.0%) by the FilmArray and 69 (30.3%) by the Luminex assay. Clostridium difficile (12.6 to 13.9% prevalence) and norovirus genogroup I (GI)/GII (5.7 to 13.9% prevalence) were two of the pathogens most commonly detected by both assays among prospective samples. Sapovirus was also commonly detected (5.7% positive rate) by the FilmArray assay. Among 270 additional previously characterized samples, both multiplex panels demonstrated high sensitivity (>90%) for the majority of targets, with the exception of several pathogens, notably Aeromonas sp. (23.8%) by FilmArray and Yersinia enterocolitica (48.1%) by the Luminex assay. Interestingly, the FilmArray and Luminex panels identified mixed infections in 21.1% and 13.0% of positive prospective samples, respectively, compared to only 8.3% by routine methods.
Answer to August 2014 Photo Quiz
Relich, Ryan F. , Faught, Phillip R., McCoy, Morgan H., Alexander, Riley E., Pritt, Bobbi S. , Pritt, Bobbi S

Journal of Clinical Microbiology | July 17, 2014 | Volume: 52 | Issue: 8 | Pages: 3138-3138

10.1128/jcm.00700-13 Get It

Photo Quiz: An Unexpected Colonoscopic Finding in a 13-Year-Old Boy
Relich, Ryan F. , Faught, Phillip R., McCoy, Morgan H., Alexander, Riley E., Pritt, Bobbi S. , Pritt, Bobbi S

Journal of Clinical Microbiology | July 17, 2014 | Volume: 52 | Issue: 8 | Pages: 2749-2749

10.1128/jcm.00699-13 Get It