Back to Authors

Moyers, Michael F.

0000-0002-8762-542X

Mayo Clinic

Fudan University

Citations 2

AAPM Task Group Report 290: Respiratory motion management for particle therapy
Li, Heng , Flampouri, Stella , Jee, Kyung‐Wook , Lin, Liyong , Moyers, Michael F. , Rottmann, J, Tryggestad, E., Vedam, Sastry, Tryggestad, Erik, Lin, Liyong , Dong, Lei , Bert, Christoph , Chang, Joe Y. , Mori, Shinichiro

Medical Physics | January 23, 2022 | Volume: 49 | Issue: 4 | Pages: No page available

10.1002/mp.15470 Get It

Abstract Dose uncertainty induced by respiratory motion remains a major concern for treating thoracic and abdominal lesions using particle beams. This Task Group report reviews the impact of tumor motion and dosimetric considerations in particle radiotherapy, current motion‐management techniques, and limitations for different particle‐beam delivery modes (i.e., passive scattering, uniform scanning, and pencil‐beam scanning). Furthermore, the report provides guidance and risk analysis for quality assurance of the motion‐management procedures to ensure consistency and accuracy, and discusses future development and emerging motion‐management strategies. This report supplements previously published AAPM report TG76, and considers aspects of motion management that are crucial to the accurate and safe delivery of particle‐beam therapy. To that end, this report produces general recommendations for commissioning and facility‐specific dosimetric characterization, motion assessment, treatment planning, active and passive motion‐management techniques, image guidance and related decision‐making, monitoring throughout therapy, and recommendations for vendors. Key among these recommendations are that: (1) facilities should perform thorough planning studies (using retrospective data) and develop standard operating procedures that address all aspects of therapy for any treatment site involving respiratory motion; (2) a risk‐based methodology should be adopted for quality management and ongoing process improvement.
Clinical commissioning of intensity‐modulated proton therapy systems: Report of AAPM Task Group 185
Farr, Jonathan B., Moyers, Michael F. , Allgower, C., Hsi, W, Jin, Hosang , Mihailidis, D, Lu, Hsiao‐Ming , Newhauser, Wayne , Sahoo, Narayan , Slopsema, R , Yeung, Daniel , Zhu, X , Bues, Martin

Medical Physics | October 20, 2020 | Volume: 48 | Issue: 1 | Pages: No page available

10.1002/mp.14546 Get It

Proton therapy is an expanding radiotherapy modality in the United States and worldwide. With the number of proton therapy centers treating patients increasing, so does the need for consistent, high‐quality clinical commissioning practices. Clinical commissioning encompasses the entire proton therapy system's multiple components, including the treatment delivery system, the patient positioning system, and the image‐guided radiotherapy components. Also included in the commissioning process are the x‐ray computed tomography scanner calibration for proton stopping power, the radiotherapy treatment planning system, and corresponding portions of the treatment management system. This commissioning report focuses exclusively on intensity‐modulated scanning systems, presenting details of how to perform the commissioning of the proton therapy and ancillary systems, including the required proton beam measurements, treatment planning system dose modeling, and the equipment needed.