Back to Authors

Snyder, Eric M.

Mayo Clinic

University of Minnesota

Citations 53

Influence of the Vibralung Acoustical Percussor on pulmonary function and sputum expectoration in individuals with cystic fibrosis
Wheatley, Courtney M. , Baker, Sarah E. , Daines, C, Phan, Hanna , Martínez, Marina González, Snyder, Eric M., Wheatley-Guy, Courtney M , Morgan, Wayne J. , Baker, Sarah E

Therapeutic Advances in Respiratory Disease | April 26, 2018 | Volume: 12 | Issue: No issue available | Pages: No page available

10.1177/1753466618770997 Get It

Background: The Vibralung Acoustical Percussor is a new airway clearance therapy (ACT) utilizing intrapulmonary sound waves in addition to positive expiratory pressure (PEP). We evaluated the safety of the Vibralung and collected preliminary data on its ability to mediate sputum expectoration in individuals with cystic fibrosis (CF). Methods: Over two separate studies, 10 and 11 mild to moderate CF patients were recruited for study I and II, respectively. Study I: Vibralung was used for 20 min with either no sound (NS: PEP only) or sound (S: PEP and sound) on randomized visits. Pulmonary function, diffusion capacity of the lungs for carbon monoxide and nitric oxide (DLCO/DLNO), symptoms, and peripheral oxygen saturation (SpO2) were measured at baseline and at 1 and 4 h post treatment. Expectorated sputum was collected over 4 h post treatment. Study II: over 5 days of in-hospital therapy, the Vibralung or vibratory vest therapy (Vest) were used for two therapy sessions per day, with sputum collected for 20 min following each therapy and pulmonary function accessed pre and post each 5-day period (days 1–5 or 7–11) in a randomized crossover design. Results: Vibralung usage resulted in no change from baseline to 4 h post in pulmonary function, SpO2 or symptoms ( p > 0.05). At 4 h post therapy, the DLCO- and DLNO-derived measure of alveolar–capillary unit function (DM/ VC) showed improvement (DM/ VC = 12.5 ± 5.5 versus 7.3 ± 18.8% change, S versus NS) with no difference between S and NS ( p = 0.74). Sputum expectoration was similar between S and NS conditions (wet sputum = 10.5 ± 4.6 versus 9.9 ± 3.2 g, S versus NS, p = 0.25). There were no differences in the improvement in pulmonary function between Vibralung and Vest during either 5-day period during the hospital stay. Conclusions: Vibralung was well tolerated and caused no detrimental changes in pulmonary function metrics. The Vibralung appears to be a safe ACT in individuals with CF.
Alveolar air and oxidative metabolic demand during exercise in healthy adults: the role of single-nucleotide polymorphisms of the β 2 AR gene
Iterson, Erik H. Van , Snyder, Eric M., Johnson, Bruce D., Van Iterson, Erik H

Physiological Reports | October 23, 2017 | Volume: 5 | Issue: 20 | Pages: e13476

10.14814/phy2.13476 Get It

Influence of Inhaled Amiloride on Lung Fluid Clearance in Response to Normobaric Hypoxia in Healthy Individuals
Wheatley, Courtney M. , Baker, Sarah E. , Taylor, Bryan J. , Keller‐Ross, Manda L. , Chase, Steven C. , Carlson, Alex R. , Wentz, Robert J., Snyder, Eric M., Johnson, Bruce D. , Taylor, Bryan J , Keller-Ross, Manda , Baker, Sarah E

High Altitude Medicine & Biology | September 6, 2017 | Volume: 18 | Issue: 4 | Pages: 343-354

10.1089/ham.2017.0032 Get It

Beta-2 Adrenergic Receptor Genotype Influences Power Output in Healthy Subjects
Kelley, Eli F. , Johnson, Bruce D., Snyder, Eric M.

Journal of Strength and Conditioning Research | May 27, 2017 | Volume: 31 | Issue: 8 | Pages: 2053-2059

10.1519/jsc.0000000000001978 Get It

Abstract Kelley, EF, Johnson, BD, and Snyder, EM. Beta-2 adrenergic receptor genotype influences power output in healthy subjects. J Strength Cond Res 31(8): 2053–2059, 2017—The purpose of this study was to determine the effects of ADRB2 genotypes on muscle function (absolute power and relative power) in healthy subjects. We performed genotyping of the ADRB2 (amino acid 16) and high-intensity, steady-state exercise on 77 healthy subjects (AA = 18, AG = 25, GG = 34). There were no differences between genotype groups in age, height, weight, or body mass index (BMI) (age = 28.9 ± 5.7 years, 27.9 ± 5.7 years, 29.2 ± 5.9 years, height = 170.7 ± 8.6 cm, 174.9 ± 8.7 cm, 173.4 ± 9.6 cm, weight = 68.5 ± 13.0 kg, 75.0 ± 12.9 kg, 74.4 ± 12.9 kg, and BMI = 23.4 ± 3.9, 24.4 ± 2.9, 24.7 ± 3.4, for AA, AG, and GG, respectively). The genotype groups differed significantly in watts, and watts/V̇ o 2 with heavy exercise (watts = 186.3 ± 54.6, 237.8 ± 54.4, 219.4 ± 79.5, watts/V̇ o 2 = 0.08 ± 0.006, 0.09 ± 0.005, 0.08 ± 0.006). There was a trend toward significance ( p = 0.058) for W·kg −1 (2.7 ± 0.4, 3.2 ± 0.5, 2.9 ± 0.8, for AA, AG, and GG, respectively). These data suggest that genetic variation of the ADRB2 may influence relative strength in healthy subjects and may become an important genetic determinant of muscular strength and functional capacity in patients with diseases that result in a loss of muscle strength.
The Influence of 17 Hours of Normobaric Hypoxia on Parallel Adjustments in Exhaled Nitric Oxide and Airway Function in Lowland Healthy Adults
Iterson, Erik H. Van , Snyder, Eric M., Johnson, Bruce D. , Van Iterson, Erik H, Van Iterson, Erik H

High Altitude Medicine & Biology | January 30, 2017 | Volume: 18 | Issue: 1 | Pages: 1-10

10.1089/ham.2016.0086 Get It

Albuterol Improves Alveolar-Capillary Membrane Conductance in Healthy Humans
Taylor, Natalie E., Baker, Sarah E. , Olson, Thomas P. , Johnson, Bruce D. , Snyder, Eric M., Lalande, Sophie , Baker, Sarah E

Clinical Medicine Insights: Circulatory, Respiratory and Pulmonary Medicine | October 12, 2016 | Volume: 10 | Issue: No issue available | Pages: CCRPM.S30251

10.4137/ccrpm.s30251 Get It

Background Beta-2 adrenergic receptors (β 2 ARs) are located throughout the body including airway and alveolar cells. The β 2 ARs regulate lung fluid clearance through a variety of mechanisms including ion transport on alveolar cells and relaxation of the pulmonary lymphatics. We examined the effect of an inhaled β 2 -agonist (albuterol) on alveolar-capillary membrane conductance (DM) and pulmonary capillary blood volume ( V C ) in healthy humans. Methods We assessed the diffusing capacity of the lungs for carbon monoxide (DLCO) and nitric oxide (DLNO) at baseline, 30 minutes, and 60 minutes following nebulized albuterol (2.5 mg, diluted in 3 mL normal saline) in 45 healthy subjects. Seventeen subjects repeated these measures following nebulized normal saline (age = 27 ± 9 years, height = 165 ± 21 cm, weight = 68 ± 12 kg, BMI = 26 ± 9 kg/m 2 ). Cardiac output (Q), heart rate, systemic vascular resistance (SVR), blood pressure, oxygen saturation, forced expiratory volume at one-second (FEV 1 ), and forced expiratory flow at 50% of forced vital capacity (FEF 50 ) were assessed at baseline, 30 minutes, and 60 minutes following the administration of albuterol or saline. Results Albuterol resulted in a decrease in SVR, and an increase in Q, FEV 1 , and FEF 50 compared to saline controls. Albuterol also resulted in a decrease in V C at 60 minutes post albuterol. Both albuterol and normal saline resulted in no change in DLCO or DM when assessed alone, but a significant increase was observed in DM when accounting for changes in V C . Conclusion These data suggest that nebulized albuterol improves pulmonary function in healthy humans, while nebulization of both albuterol and saline results in an increase in DM/ V C .
Reliability of Triaxial Accelerometry for Measuring Load in Men's Collegiate Ice Hockey
Iterson, Erik H. Van , Fitzgerald, John S. , Dietz, Calvin C., Snyder, Eric M., Peterson, Ben , Van Iterson, Erik H, Van Iterson, Erik H

Journal of Strength and Conditioning Research | August 20, 2016 | Volume: 31 | Issue: 5 | Pages: 1305-1312

10.1519/jsc.0000000000001611 Get It

Abstract Van Iterson, EH, Fitzgerald, JS, Dietz, CC, Snyder, EM, and Peterson, BJ. Reliability of triaxial accelerometry for measuring load in men's collegiate ice hockey. J Strength Cond Res 31(5): 1305–1312, 2017—Wearable microsensor technology incorporating triaxial accelerometry is used to quantify an index of mechanical stress associated with sport-specific movements termed PlayerLoad. The test-retest reliability of PlayerLoad in the environmental setting of ice hockey is unknown. The primary aim of this study was to quantify the test-retest reliability of PlayerLoad in ice hockey players during performance of tasks simulating game conditions. Division I collegiate male ice hockey players ( N = 8) wore Catapult Optimeye S5 monitors during repeat performance of 9 ice hockey tasks simulating game conditions. Ordered ice hockey tasks during repeated bouts included acceleration (forward or backward), 60% top-speed, top-speed (forward or backward), repeated shift circuit, ice coasting, slap shot, and bench sitting. Coefficient of variation (CV), intraclass correlation coefficient (ICC), and minimum difference (MD) were used to assess PlayerLoad reliability. Test-retest CVs and ICCs of PlayerLoad were as follows: 8.6% and 0.54 for forward acceleration, 13.8% and 0.78 for backward acceleration, 2.2% and 0.96 for 60% top-speed, 7.5% and 0.79 for forward top-speed, 2.8% and 0.96 for backward top-speed, 26.6% and 0.95 for repeated shift test, 3.9% and 0.68 for slap shot, 3.7% and 0.98 for coasting, and 4.1% and 0.98 for bench sitting, respectively. Raw differences between bouts were not significant for ice hockey tasks ( p > 0.05). For each task, between-bout raw differences were lower vs. MD: 0.06 vs. 0.35 (forward acceleration), 0.07 vs. 0.36 (backward acceleration), 0.00 vs. 0.06 (60% top-speed), 0.03 vs. 0.20 (forward top-speed), 0.02 vs. 0.09 (backward top-speed), 0.18 vs. 0.64 (repeated shift test), 0.02 vs. 0.10 (slap shot), 0.00 vs. 0.10 (coasting), and 0.01 vs. 0.11 (bench sitting), respectively. These data suggest that PlayerLoad demonstrates moderate-to-large test-retest reliability in the environmental setting of male Division I collegiate ice hockey. Without previously testing reliability, these data are important as PlayerLoad is routinely quantified in male collegiate ice hockey to assess on ice physical activity.
Impact of chronic systolic heart failure on lung structure-function relationships in large airways
Chase, Steven C. , Wheatley, Courtney M. , Olson, Lyle J. , Beck, Kenneth C., Wentz, Robert J., Snyder, Eric M., Taylor, Bryan J. , Johnson, Bruce D. , Taylor, Bryan J

Physiological Reports | July 14, 2016 | Volume: 4 | Issue: 13 | Pages: e12867

10.14814/phy2.12867 Get It

Off-Ice Anaerobic Power Does Not Predict On-Ice Repeated Shift Performance in Hockey
Peterson, Ben , Fitzgerald, John S. , Dietz, Calvin C., Ziegler, Kevin S., Baker, Sarah E. , Snyder, Eric M., Peterson, Ben J, Baker, Sarah E

Journal of Strength and Conditioning Research | January 24, 2016 | Volume: 30 | Issue: 9 | Pages: 2375-2381

10.1519/jsc.0000000000001341 Get It

Abstract Peterson, BJ, Fitzgerald, JS, Dietz, CC, Ziegler, KS, Baker, SE, and Snyder, EM. Off-ice anaerobic power does not predict on-ice repeated shift performance in hockey. J Strength Cond Res 30(9): 2375–2381, 2016—Anaerobic power is a significant predictor of acceleration and top speed in team sport athletes. Historically, these findings have been applied to ice hockey although recent research has brought their validity for this sport into question. As ice hockey emphasizes the ability to repeatedly produce power, single bout anaerobic power tests should be examined to determine their ability to predict on-ice performance. We tested whether conventional off-ice anaerobic power tests could predict on-ice acceleration, top speed, and repeated shift performance. Forty-five hockey players, aged 18–24 years, completed anthropometric, off-ice, and on-ice tests. Anthropometric and off-ice testing included height, weight, body composition, vertical jump, and Wingate tests. On-ice testing consisted of acceleration, top speed, and repeated shift fatigue tests. Vertical jump (VJ) ( r = −0.42; r = −0.58), Wingate relative peak power (WRPP) ( r = −0.32; r = −0.43), and relative mean power (WRMP) ( r = −0.34; r = −0.48) were significantly correlated ( p ≤ 0.05) to on-ice acceleration and top speed, respectively. Conversely, none of the off-ice tests correlated with on-ice repeated shift performance, as measured by first gate, second gate, or total course fatigue; VJ ( r = 0.06; r = 0.13; r = 0.09), WRPP ( r = 0.06; r = 0.14; r = 0.10), or WRMP ( r = −0.10; r = −0.01; r = −0.01). Although conventional off-ice anaerobic power tests predict single bout on-ice acceleration and top speed, they neither predict the repeated shift ability of the player, nor are good markers for performance in ice hockey.
Importance of the Kidney, Vessels, and Heart with Administration of β2 Adrenergic Receptor Agonists in Patients Susceptible to Acute Respiratory Distress Syndrome
Snyder, Eric M., Johnson, Bruce D.

American Journal of Respiratory and Critical Care Medicine | June 1, 2014 | Volume: 189 | Issue: 11 | Pages: 1445-1447

10.1164/rccm.201404-0610le Get It