Iatrogenic spinal arachnoid cysts are rare, but have been described as a complication of spinal injection and lumbar puncture procedures. The authors describe 2 cases of iatrogenic spinal arachnoid cyst formation that occurred after incidental durotomy during lumbar spine surgery. In both cases, postoperative MR imaging revealed compression of the cauda equina by an intradural arachnoid cyst. Intradural exploration and fenestration of the arachnoid cyst was accomplished in each case. This entity should be considered in the differential diagnosis of a patient experiencing symptoms of neurological compression after a lumbar surgery complicated by incidental durotomy.
Treatment of Urinary Incontinence Due to Incomplete Spinal Cord Injury With Acupuncture and Percutaneous Electrical Nerve Stimulation: Two Cases and Literature Review
Object The goal of this study was to analyze the placement accuracy and complications of thoracolumbar pedicle screws (PSs) inserted using 3D image guidance in a large patient cohort. Methods The authors reviewed the charts of 220 consecutive patients undergoing posterior spinal fusion using 3D image guidance for instrumentation placement. A total of 1084 thoracolumbar PSs were placed using either the BrainLAB Vector Vision (BrainLAB, Inc.) or Medtronic StealthStation Treon (Medtronic, Inc.) image guidance systems. Postoperative CT scanning was performed in 184 patients, allowing for 951 screws to be graded by an independent radiologist for bone breach. All complications resulting from instrumentation placement were noted. Using the intraoperative planning function of the image-guided system, the largest diameter screw possible in each particular case was placed. The screw diameter of instrumentation placed into the L3–S1 levels was noted. Results No vascular or visceral complications occurred as a result of screw placement. Two nerve root injuries occurred in 1084 screws placed, resulting in a 0.2% per screw incidence and a 0.9% patient incidence of nerve root injury. Neither nerve root injury was associated with a motor deficit. The breach rate was 7.5%. Grade 1 and minor anterolateral “tip out” breaches accounted for 90% of the total breaches. Patients undergoing revision surgery accounted for 46% of the patients in this study. Accordingly, 154 screws placed through previous fusion mass could be evaluated using postoperative CT scanning. The breach rate in this specific cohort was 7.8%. A total of 765 PSs were placed into the L3–S1 levels in this study; 546 (71%) of these screws were ≥ 7.5 mm in diameter. No statistical difference in breach rate was noted in PSs placed through revision spinal levels versus nonrevision spinal levels (p = 0.499). Additionally, no increase in breach rate was noted with placement of 7.5-mm-diameter screws. Conclusions Three-dimensional image guidance is a useful adjunct to placement of spinal instrumentation. The complication rate in this study was low, and accurate placement of instrumentation was achieved despite the high percentage of revision surgery cases in our patient population. Additionally, because active fluoroscopy was not used for instrumentation placement, there was minimal to no radiation exposure to the surgeon or operating room staff.
Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques
ObjectStabilization of the atlantoaxial complex has proven to be very challenging. Because of the high mobility of the C1–2 motion segment, fusion rates at this level have been substantially lower than those at the subaxial spine. The set of potential surgical interventions is limited by the anatomy of this region. In 2001 Jürgen Harms described a novel technique for individual fixation of the C-1 lateral mass and the C-2 pedicle by using polyaxial screws and rods. This method has been shown to confer excellent stability in biomechanical studies. Cadaveric and radiographic analyses have indicated that it is safe with respect to osseous and vascular anatomy. Clinical outcome studies and fusion rates have been limited to small case series thus far. The authors reviewed the multicenter experience with 102 patients undergoing C1–2 fusion via the polyaxial screw/rod technique. They also describe a modification to the Harms technique.MethodsOne hundred two patients (60 female and 42 male) with an average age of 62 years were included in this analysis. The average follow-up was 16.4 months. Indications for surgery were instability at the C1–2 level, and a chronic Type II odontoid fracture was the most frequent underlying cause. All patients had evidence of instability on flexion and extension studies. All underwent posterior C-1 lateral mass to C-2 pedicle or pars screw fixation, according to the method of Harms. Thirty-nine patients also underwent distraction and placement of an allograft spacer into the C1–2 joint, the authors' modification of the Harms technique. None of the patients had supplemental sublaminar wiring.ResultsAll but 2 patients with at least a 12-month follow-up had radiographic evidence of fusion or lack of motion on flexion and extension films. All patients with an allograft spacer demonstrated bridging bone across the joint space on plain x-ray films and computed tomography. The C-2 root was sacrificed bilaterally in all patients. A postoperative wound infection developed in 4 patients and was treated conservatively with antibiotics and local wound care. One patient required surgical debridement of the wound. No patient suffered a neurological injury. Unfavorable anatomy precluded the use of C-2 pedicle screws in 23 patients, and thus, they underwent placement of pars screws instead.ConclusionsFusion of C1–2 according to the Harms technique is a safe and effective treatment modality. It is suitable for a wide variety of fracture patterns, congenital abnormalities, or other causes of atlantoaxial instability. Modification of the Harms technique with distraction and placement of an allograft spacer in the joint space may restore C1–2 height and enhance radiographic detection of fusion by demonstrating a graft–bone interface on plain x-ray films, which is easier to visualize than the C1–2 joint.