AbstractSaccular aneurysms (SAs) are focal outpouchings from the lateral wall of an artery. Depending on their morphology and location, minimally invasive treatment options include coil embolization, flow diverter stents, stent‐assisted coiling, and liquid embolics. Many drawbacks are associated with these treatment options including recanalization, delayed healing, rebleeding, malpositioning of the embolic or stent, stent stenosis, and even rupture of the SA. To overcome these drawbacks, a nanoclay‐based shear‐thinning hydrogel (STH) is developed for the endovascular treatment of SAs. Extensive in vitro testing is performed to optimize STH performance, visualization, injectability, and endothelialization in cell culture. Femoral artery saccular aneurysm models in rats and in pigs are created to test stability, efficacy, immune response, endothelialization, and biocompatibility of STH in both ruptured and unruptured SA. Fluoroscopy and computed tomography imaging consistently confirmed SA occlusion without recanalization, migration, or nontarget embolization; STH is also shown to outperform coil embolization of porcine aneurysms. In pigs with catastrophic bleeding due to SA rupture, STH is able to achieve instant hemostasis rescuing the pigs in long‐term survival experiments. STH is a promising semisolid iodinated embolic agent that can change the standard of medical practice and potentially save lives.
Percutaneous liquid ablation agent for tumor treatment and drug delivery
AbstractEndovascular embolization to treat vascular hemorrhage involves pushing coil‐shaped metal wires into the artery repeatedly until they are densely packed to slow the blood flow and clot. However, coil embolization is associated with high rebleeding rates, unpredictable economics and, most importantly, they rely on the patient's ability to make a clot. These issues are exacerbated when the patient is anticoagulated or coagulopathic. A novel bioengineered tantalum‐loaded nanocomposite hydrogel for gel embolic material (Ta‐GEM) that can be rapidly delivered using clinical catheters for instant hemostasis regardless of the coagulopathic state is reported. Ta‐GEM formulation is visible by most of the clinically available imaging modalities including ultrasound, computed tomography, magnetic resonance imaging, and fluoroscopy without significant artifact. In addition, Ta‐GEM can be retrieved, allowing temporary vascular occlusion, and it can be used to rescue cases of failed coil embolization. Ta‐GEM occlusion of first‐order arteries such as the renal artery and iliac artery in a swine model is found to be safe and durable; by 28 days, 75% of the injected Ta‐GEM in the arterial lumen is replaced by dense connective tissue. Altogether, this study demonstrates that Ta‐GEM has many advantages over the current technologies and has potential applications in clinical practice.
Blood‐Derived Biomaterial for Catheter‐Directed Arterial Embolization
AbstractVascular embolization is a life‐saving minimally invasive catheter‐based procedure performed to treat bleeding vessels. Through these catheters, numerous metallic coils are often pushed into the bleeding artery to stop the blood flow. While there are numerous drawbacks to coil embolization, physician expertise, availability of these coils, and their costs further limit their use. Here, a novel blood‐derived embolic material (BEM) with regenerative properties, that can achieve instant and durable intra‐arterial hemostasis regardless of coagulopathy, is developed. In a large animal model of vascular embolization, it is shown that the BEM can be prepared at the point‐of‐care within 26 min using fresh blood, it can be easily delivered using clinical catheters to embolize renal and iliac arteries, and it can achieve rapid hemostasis in acutely injured vessels. In swine arteries, the BEM increases cellular proliferation, angiogenesis, and connective tissue deposition, suggesting vessel healing and durable vessel occlusion. The BEM has significant advantages over embolic materials used today, making it a promising new tool for embolization.
Nanocomposite Hydrogels: Bioactive‐Tissue‐Derived Nanocomposite Hydrogel for Permanent Arterial Embolization and Enhanced Vascular Healing (Adv. Mater. 33/2020)
AbstractTranscatheter embolization is a minimally invasive procedure that uses embolic agents to intentionally block diseased or injured blood vessels for therapeutic purposes. Embolic agents in clinical practice are limited by recanalization, risk of non‐target embolization, failure in coagulopathic patients, high cost, and toxicity. Here, a decellularized cardiac extracellular matrix (ECM)‐based nanocomposite hydrogel is developed to provide superior mechanical stability, catheter injectability, retrievability, antibacterial properties, and biological activity to prevent recanalization. The embolic efficacy of the shear‐thinning ECM‐based hydrogel is shown in a porcine survival model of embolization in the iliac artery and the renal artery. The ECM‐based hydrogel promotes arterial vessel wall remodeling and a fibroinflammatory response while undergoing significant biodegradation such that only 25% of the embolic material remains at 14 days. With its unprecedented proregenerative, antibacterial properties coupled with favorable mechanical properties, and its superior performance in anticoagulated blood, the ECM‐based hydrogel has the potential to be a next‐generation biofunctional embolic agent that can successfully treat a wide range of vascular diseases.