Background— Outflow tract ventricular tachycardia originating above the semilunar valves has been reported in a small number of studies. Discrete potentials in the great arteries (above the semilunar valves) have been rarely described in patients undergoing electrophysiology evaluation and radiofrequency ablation for ventricular arrhythmias. The mechanisms of these discrete potentials in the great arteries and the utility of such potentials in guiding radiofrequency ablation are unknown. Methods and Results— Twelve patients with outflow tract ventricular arrhythmia originating above the semilunar valves with discrete arterial potentials were studied. The clinical characteristics, properties of the arterial potentials, electrophysiological evaluation and ablation, and short- and long-term outcomes were reviewed. Of the twelve patients, 8 (67%) were women. The patients’ average age was 41�14 years. The average ejection fraction was 0.52�0.16 (range: 0.16 to 0.75). Contact mapping in the great artery demonstrated discrete near-field electrograms that were separate from far-field ventricular electrograms in all patients (8 above the pulmonary valve and in 4 the aortic valve). One or more of the following electrophysiological characteristics, supportive of an arrhythmogenic substrate, were observed in 10 of 12 patients: (1) A fixed or reproducibly variable pattern of discrete potential–ventricular arrhythmia relationship was present at baseline or during pacing; (2) the discrete potential–ventricular electrogram relationship during sinus rhythm was the reverse of that during the ventricular arrhythmia; (3) during sustained ventricular tachycardia, spontaneous variation of the ventricular (V-V) cycle length was preceded by a similar variation of arterial spike potential–spike potential cycle length; and (4) ablation guided by the discrete arterial potential successfully eliminated the clinical arrhythmia. Ablation was successful in these patients. In the remaining 2 patients, the potentials were believed to be bystanders. Over 10�4 months (range: 5 to 32 months) of follow-up, there have been no recurrences of the premature ventricular complex or ventricular arrhythmia. Conclusions— Discrete potentials are present in the great arteries of a select group of patients with outflow tract ventricular tachycardia originating above the semilunar valves. When an arrhythmogenic relationship can be demonstrated, discrete potentials are useful in guiding ablation within the great vessels, despite significant anatomic complexity.
Catheter Ablation for Atrial Fibrillation in Patients With Obesity
Background— Obesity is a risk factor for atrial fibrillation and other cardiovascular conditions. Our objective was to determine whether catheter-based ablation effectively treated atrial fibrillation in obese patients. Methods and Results— Five hundred twenty-three consecutive patients with symptomatic, medication-refractory atrial fibrillation underwent catheter ablation. Patients were grouped by body mass index (lean, <25 kg/m 2 ; overweight, 25 to 29.9 kg/m 2 ; obese, ≥30 kg/m 2 ). Outcome and quality of life were measured with a general health survey (Medical Outcomes Study 36-item Short-Form General Health Survey [SF-36]); patients were assessed before ablation and at 3 and 12 months after the procedure. Two hundred twenty-eight study patients (44%) were overweight, and 201 (38%) were obese. Twelve months after curative ablation, 72% of patients were free of atrial fibrillation without the use of antiarrhythmic agents; 84% were arrhythmia free when those receiving medication were included. Atrial fibrillation was eliminated in 75%, 72%, and 70% of the lean, overweight, and obese patients, respectively, at 12 months ( P =0.41, trend test). SF-36 scores were lower for patients with higher body mass index ( P <0.05) at baseline. SF-36 scores improved in every functional domain for all body mass index groups after ablation. The mean SF-36 total physical score increased from 59±20 at baseline to 77±19 in 12 months ( P <0.001). The total mental health score improved from 66±18 to 79±16 in 12 months ( P <0.001). Conclusions— Catheter ablation of atrial fibrillation was effective in obese patients. Coexistence of atrial fibrillation and obesity indicated lower SF-36 scores, but the improvement in quality of life was consistent across all body mass index categories.
Background— Although segmental or circumferential ablation is effective in eliminating pulmonary vein (PV)–mediated atrial fibrillation (AF), this procedure may be complicated by the occurrence of PV stenosis. Methods and Results— To establish the clinical presentation, diagnostic manifestations, and interventional management of PV stenosis, 23 patients with stenosis of 34 veins complicating ablation of AF were evaluated. Each patient became symptomatic 103±100 days after undergoing ablation. In 8 veins, the ablation producing the PV stenosis was a repeated procedure for continued AF. Nineteen patients presented with dyspnea on exertion, 7 with dyspnea at rest, 9 with cough, and 6 with chest pain. On multirow spiral computed tomography examination, the narrowest lumen of the affected PVs measured 3±2 mm compared with 13±3 mm at baseline ( P ≤0.001). The relative perfusion of affected lung segments on isotope scans was reduced to 4±3% of total perfusion compared with 22±10% in unaffected segments. At percutaneous intervention, these veins showed 80±13% stenosis, with a mean gradient of 12±5 mm Hg. This was significantly reduced to a residual stenosis of 9±8% ( P ≤0.001) and a residual gradient of 3±4 mm Hg ( P ≤0.001). Twenty veins were treated with balloon dilatation alone, whereas 14 veins were stented with standard 10-mm-diameter bare-metal stents. Although the symptomatic response was nearly immediate and impressive, 14 patients developed in-stent or in-segment restenosis, requiring repeated interventions in 13. Conclusions— Percutaneous intervention produces rapid and dramatic symptom relief in patients with highly symptomatic PV stenosis after radiofrequency ablation for AF. Nevertheless, alternative treatment methods will be required to decrease recurrent in-stent or in-segment restenosis.