0602 Personalized CPAP Adherence with SleepWell24: Early Outcomes of an Adaptive Smartphone Application Using Control Systems Engineering Approaches
Petrov, Megan, Khan, Owais, Rivera, Daniel, Buman, M. P. , Morgenthaler, TI, Goswami, Umesh, Yu, Tsung-Yen, Anand, Harsh, Carlock, Victoria, Dorich, Chelsea, Petrov, Megan, Rivera, Daniel E.

SLEEPJ | May 9, 2026 | Volume: 49 | Issue: Supplement_1 | Pages: A267-A268

10.1093/sleep/zsag091.0601 Get It

Abstract Introduction Adherence to continuous positive airway pressure (CPAP) therapy is difficult for many patients with obstructive sleep apnea. Clinical outcomes are improved with CPAP adherence ≥6 hr/night, yet scalable approaches to personalized support are limited. We developed a theory-based, clinic experience–driven conceptual dynamical model for optimizing CPAP use and applied it to a ‘just-in-time’ adaptive version of SleepWell24, a smartphone application integrating near–real-time wearable data, CPAP use, and patient-reported symptoms and CPAP-related problems with evidence-based behavior change interventions. In this feasibility optimization trial, we examined patient acceptability and initial outcomes of the adaptive SleepWell24 platform, and guided by the conceptual model, evaluated a control systems engineering approach to demonstrate, in simulation, improved CPAP adherence. Methods Aim 1: Naïve CPAP users (N=10; M age=61.7, 60% female) participated in this 60-day ongoing trial. Patients were encouraged to interact daily with SleepWell24 to report symptoms, receive personalized troubleshooting recommendations, set goals, and receive feedback on CPAP use (via Wi-Fi-enabled smart plug assessing CPAP ‘on/off state’) and sleep/activity (Fitbit). We assessed SleepWell24 use, post-intervention acceptability, and consistent CPAP use defined as ≥6hr, for ≥6nights/week for ≥2 consecutive weeks. Aim 2: The conceptual model of CPAP adherence produced a dynamical system, informed by Model Predictive Control (MPC) as a decision-making algorithm to optimize CPAP use to ≥6hr/night by tailoring actionable behavioral recommendations using patient data integrated in real-time. Results Aim 1: Across the 60-day trial, average daily SleepWell24 engagement was 72.7%. Median CPAP adherence of ≥6hr/night was 65.8%. All participants (100%) rated SleepWell24 as moderately-to-totally acceptable and would recommend it; perceived helpfulness averaged 7.0 (of 10). Eighty percent achieved consistent CPAP use. Aim 2: In simulation, the MPC framework managed CPAP-associated symptoms (e.g., nasal, anxiety, leak) and adjusted CPAP use goals, improving predicted CPAP adherence and sleep duration and quality. Conclusion SleepWell24 was engaging, acceptable, and helpful, with most users reaching optimal CPAP use. We will next estimate dynamical models using data from trial patients, a necessary step towards full automation of SleepWell24. Support (if any) AASMF #285-SR-22
0695 Sleepwell24, A Smartphone Application To Promote PAP Therapy Adherence: Feasibility And Acceptability
Hasanaj, Kristina , Hoffmann, Coles M., Epstein, Dana R. , Krahn, L, Park, J G, Hollingshead, Kevin , Yu, Tsung-Yen, Louis, Ermaze, Buman, M. P. , Petrov, Megan E. Ruiter , Louis, E K St., Morgenthaler, Timothy I.

Sleep | May 27, 2020 | Volume: 43 | Issue: Supplement_1 | Pages: A265-A265

10.1093/sleep/zsaa056.691 Get It

Abstract Introduction We aimed to test the feasibility and acceptability of SleepWell24, a multicomponent, smartphone-delivered intervention to increase positive airway pressure (PAP) adherence among newly diagnosed OSA patients. Methods SleepWell24 targets PAP adherence along with other health behaviors through education, trouble-shooting, goal-setting, and near real-time biofeedback of PAP machine use, and sleep and physical activity levels (via Fitbit integration), and other chronic disease self-management components. Patients with a first-time diagnosis of OSA (AHI≥5) and prescribed PAP therapy were enrolled from the Centers for Sleep Medicine at Mayo Clinic in Rochester, MN and Phoenix, AZ. Patients were randomized to SleepWell24 or usual care (UC) and assessed for PAP use over 60 consecutive nights. UC patients received a Fitbit monitor to control for non-specific intervention effects related to the introduction of a new personal technology. Feasibility was assessed with recruitment and retention rates and acceptability was assessed post-intervention with the validated, 8-item Treatment Evaluation Questionnaire (TEQ; range:0-4). ANCOVA models, adjusting for age, sex, and AHI severity, compared intervention arms on acceptability ratings. Results OSA patients were consented and randomized (N=111). Before the intervention began 4 participants withdrew, 12 were lost to follow-up, and 5 could not start the trial due to durable medical equipment (DME) vendor barriers. Ninety OSA patients (n=41 SleepWell24, n=49 UC; age M±SD=57.2±12.2; 44.4% female, 61.1% AHI≥15) started the intervention, with 2 participants withdrawing, 1 becoming deceased (unrelated to treatment) and 7 with missing PAP data due to DME vendor barriers. There was no significant between-groups differences on post-treatment acceptability (SleepWell24 M±SD=2.7±1.1 vs. UC M±SD=3.1±0.9, F[1,73]=2.3, p=0.11), and 77% of SleepWell24 participants found the app to be moderately to totally acceptable. Conclusion Overall, SleepWell24 was found to be feasible for delivery in two large clinical sleep medicine centers, and patients found the app to be acceptable. A number of challenges in trial delivery were encountered that have implications for scaled-up efficacy testing: (a) partnerships with DME vendors for near real-time PAP data integration; (b) alignment with clinical practice (i.e., referral, medical record integration); and (c) patient engagement. Support National Institute of Nursing Research / National Institutes of Health: R21NR016046
Postexercise Hemodynamic Responses in Lean and Obese Men
Zeigler, Zachary , Swan, Pamela D. , Buman, Matthew P. , Mookadam, Farouk , Angadi, Siddhartha S. , Mookadam, Farouk , Gaesser, Glenn A. , Buman, M. P.

Medicine & Science in Sports & Exercise | June 10, 2018 | Volume: 50 | Issue: 11 | Pages: 2292-2300

10.1249/mss.0000000000001684 Get It

ABSTRACT Purpose We assessed resting central/peripheral blood pressure (BP), postexercise BP, and hemodynamic responses (stroke volume, cardiac output, and systemic vascular resistance) after acute exercise and 2 wk of aerobic training in lean and centrally obese men matched for BP. Methods Eight lean (body mass index < 25 kg·m −2 , visceral fat = 279 ± 224 cm 3 ) and eight centrally obese (body mass index > 30 kg·m −2 , visceral fat = 1471 ± 374 cm 3 ) men performed six training sessions (3 d·wk −1 for 40 min at 65%–70% HR max ). Resting BP and hemodynamic measurements were obtained at baseline, after exercise for 60 min, and at 24 h and 48 h after the last training session. Results Postexercise brachial and central systolic BP (SBP) and mean arterial BP decreased 3–4 mm Hg below resting in lean ( P < 0.001) and increased by 3 mm Hg in obese ( P < 0.02). Posttraining resting brachial/central SBP were reduced by 3–4 mm Hg only in lean men ( P < 0.05). Pretraining postexercise hypotension was significantly correlated with the training-induced change in resting brachial SBP at 48 h ( r = 0.58, P = 0.02), but not at 24 h ( r = 0.38, P = 0.15). Similar correlations were observed between acute reductions in central SBP and central SBP at 24 h ( r = 0.43, P = 0.09) and 48 h ( r = 0.54, P = 0.03) posttraining. Conclusions In contrast to the consistent results for lean men, postexercise hypotension was not observed in centrally obese men, and resting SBP was not reduced after a short aerobic training program. Considerable individual variation in postexercise BP response among obese men may have implications for design of exercise interventions to lower BP in these individuals.