The in vivo and in vitro effect of phenylephrine (neo synephrine) on nasal ciliary beat frequency and mucociliary transport
Phillips, P. Perry, McCaffrey, Thomas V., Kern, Eugene B.

Otolaryngology–Head and Neck Surgery | April 21, 2016 | Volume: 103 | Issue: 4 | Pages: 558-565

10.1177/019459989010300406 Get It

Twenty volunteers with normal noses were studied to determine the effect of phenylephrine on nasal ciliary function. In vivo study of this drug was performed in 15 patients and revealed a significant increase in their ciliary beat frequency from a control of 11 Hz to 12.03 Hz (p = 0.001). Mucociliary transit times in these volunteers were also studied, revealing a mean of 9.9 minutes prestimulation and 10.2 minutes poststimulation, which was not statistically significant (p = 0.77). Five additional subjects donated ciliated mucosal samples for in vitro analysis of varying concentrations of this agent that showed a significant ciliostimulatory effect at lower concentrations (0.01%), with a progressive cilioinhibitory effect at higher concentrations (0.25%, 0.5%). The 0.05% concentration showed no significant change in ciliary activity compared to control measurements. These data demonstrate that phenylephrine has a ciliostimulatory effect in vivo, as well as in appropriate concentrations in vitro, and should be safe and relatively nontoxic to the mucociliary apparatus for short‐term use.3
Measurement of Human Nasal Ciliary Motility Using Computerized Microphotometry
Phillips, P. Perry, McCaffrey, Thomas V., Kern, Eugene B.

Otolaryngology–Head and Neck Surgery | April 8, 2016 | Volume: 103 | Issue: 3 | Pages: 420-426

10.1177/019459989010300313 Get It

A new computerized technique for the assessment of human nasal ciliary beat frequency is described. Thirty normal volunteers underwent nasal cytologic brushing to obtain ciliary samples. In each subject, 150 ciliary beats were analyzed from each of 50 separate ciliated cell clusters. The ciliary beat frequency for each area was determined with fast Fourier transformation. The results were plotted on a histogram to determine the ciliary beat distribution. The mean frequency for these samples was 11.29 Hz, with a standard deviation of 0.96 Hz. The median frequency for these samples was 11.25 Hz. These results show a marked improvement over hand‐counting microphotometry techniques because of the much larger sampling size and elimination of much human error. We believe this method of ciliary analysis represents a significant advancement in the evaluation of ciliary function and should assist in the diagnosis of patients with congenital and acquired forms of ciliary dysmotility.
Primary Ciliary Dyskinesia in an Adolescent Male
Phillips, P. Perry, Kern, Eugene B.

American Journal of Rhinology | September 27, 2007 | Volume: 5 | Issue: 5 | Pages: 187-192

10.2500/105065891782009243 Get It

Nasal obstruction and recurrent sinusitis are among the most common problems encountered by rhinologists in daily practice. Unfortunately, the occurrence of primary ciliary dyskinesia and the symptoms common to this entity often lead to months or years of delayed diagnosis. Many testing methods have been used including phase contrast and electron microscopy although consensus on diagnosis and treatment has not been established. Described in this report is a male adolescent with this disorder and a new method of ciliary testing we have developed to aid in diagnosis.