Back to Authors

Ellington, Allison A.

Mayo Clinic

Division of Cardiovascular Diseases

Citations 4

Antibody-Based Protein Multiplex Platforms: Technical and Operational Challenges
Ellington, Allison A., Bailey, Kent R. , Klee, George G., Kullo, Iftikhar J.

Clinical Chemistry | December 3, 2009 | Volume: 56 | Issue: 2 | Pages: 186-193

10.1373/clinchem.2009.127514 Get It

Abstract Background: The measurement of multiple protein biomarkers may refine risk stratification in clinical settings. This concept has stimulated development of multiplexed immunoassay platforms that provide multiple, parallel protein measurements on the same specimen. Content: We provide an overview of antibody-based multiplexed immunoassay platforms and discuss technical and operational challenges. Multiplexed immunoassays use traditional immunoassay principles in which high-affinity capture ligands are immobilized in parallel arrays in either planar format or on microspheres in suspension. Development of multiplexed immunoassays requires rigorous validation of assay configuration and analytical performance to minimize assay imprecision and inaccuracy. Challenges associated with multiplex configuration include selection and immobilization of capture ligands, calibration, interference between antibodies and proteins and assay diluents, and compatibility of assay limits of quantification. We discuss potential solutions to these challenges. Criteria for assessing analytical multiplex assay performance include the range of linearity, analytical specificity, recovery, and comparison to a quality reference method. Quality control materials are not well developed for multiplexed protein immunoassays, and algorithms for interpreting multiplex quality control data are needed. Summary: Technical and operational challenges have hindered implementation of multiplexed assays in clinical settings. Formal procedures that guide multiplex assay configuration, analytical validation, and quality control are needed before broad application of multiplexed arrays can occur in the in vitro diagnostic market.
Measurement and Quality Control Issues in Multiplex Protein Assays: A Case Study
Ellington, Allison A., Bailey, Kent R. , Klee, George G., Kullo, Iftikhar J.

Clinical Chemistry | April 16, 2009 | Volume: 55 | Issue: 6 | Pages: 1092-1099

10.1373/clinchem.2008.120717 Get It

Abstract Background: Multiplex arrays are increasingly used for measuring protein biomarkers. Advantages of this approach include specimen conservation, limited sample handling, and decreased time and cost, but the challenges of optimizing assay format for each protein, selecting common dilution factors, and establishing robust quality control algorithms are substantial. Here, we use measurements of 15 protein biomarkers from a large study to illustrate processing, analytic, and quality control issues with multiplexed immunoassays. Methods: We contracted with ThermoScientific for duplicate measurements of 15 proteins in 2322 participants from a community-based cohort, a plasma control, and recombinant protein controls using 2 custom planar microarrays with 6 (panel A) or 9 (panel B) capture antibodies printed in each well. We selected constituent analytes in each panel based on endogenous concentrations and assay availability. Protocols were standardized for sample processing, storage, and freeze-thaw exposures. We analyzed data for effects of deviations from processing protocols, precision, and bias. Results: Measurements were within reportable ranges for each of the assays; however, concentrations for 7 of the 15 proteins were not centered on the dose–response curves. An additional freeze-thaw cycle and erroneous sample dilution for a subset of samples produced significantly different results. Measurements with large differences between duplicates were seen to cluster by analyte, plate, and participant. Conventional univariate quality control algorithms rejected many plates. Plate-specific medians of cohort and plasma control data significantly covaried, an observation important for development of alternative quality control algorithms. Conclusions: Multiplex measurements present difficult challenges that require further analytical and statistical developments.
Response to Resistin, Glomerular Filtration Rate, and Insulin Resistance
Ellington, Allison A., Malik, A. Rauoof , Klee, George G., Kullo, Iftikhar J.

Hypertension | January 3, 2008 | Volume: 51 | Issue: 2 | Pages: No page available

10.1161/hypertensionaha.107.102053 Get It

Association of Plasma Resistin With Glomerular Filtration Rate and Albuminuria in Hypertensive Adults
Ellington, Allison A., Malik, A. Rauoof , Klee, George G., Turner, Stephen T. , Rule, Andrew D. , Mosley, Thomas H. , Kullo, Iftikhar J.

Hypertension | September 5, 2007 | Volume: 50 | Issue: 4 | Pages: 708-714

10.1161/hypertensionaha.107.095257 Get It

Resistin, a recently discovered proinflammatory cytokine, has been variably associated with insulin resistance, inflammation, and renal dysfunction. We investigated the association of plasma resistin with estimated glomerular filtration rate and albuminuria in 1575 hypertensive adults without known coronary heart disease or stroke (857 blacks and 718 non-Hispanic whites). Resistin was measured by a solid phase sandwich immunoassay, estimated glomerular filtration rate was estimated from serum creatinine, and albuminuria was expressed as urine albumin:creatinine ratio. After adjustment for coronary heart disease risk factors (age, sex, body mass index, smoking history, systolic blood pressure, diabetes, and total and high-density lipoprotein cholesterol) and use of renin-angiotensin blockers and statins, higher plasma resistin levels were associated with lower estimated glomerular filtration rate in both ethnic groups (each P <0.0001); the association remained significant after further adjustment for a marker of insulin resistance (homeostasis model assessment for insulin resistance) and a marker of inflammation (plasma C-reactive protein) and was seen in subjects with and without diabetes (each P <0.0001) in both ethnic groups. Higher plasma resistin levels were associated with a higher urine albumin:creatinine ratio in black subjects with diabetes ( P <0.0001) and non-Hispanic white subjects with diabetes ( P =0.032), independent of coronary heart disease risk factors, hypertension medication use, and statin use; the association remained significant after additional adjustment for homeostasis model assessment for insulin resistance and C-reactive protein. In adults with hypertension, higher circulating resistin levels were associated with a lower estimated glomerular filtration rate and with increased urine albumin:creatinine ratio in the presence of concomitant diabetes. This association was independent of coronary heart disease risk factors and markers of insulin resistance and inflammation.