Back to Authors

Maning, Jennifer

https://orcid.org/0000-0002-4772-4482

Mayo Clinic

Northwestern Hospital, Chicago, IL, USA

Citations 2

In-hospital outcomes of septal myectomy vs. alcohol septal ablation for hypertrophic cardiomyopathy with outflow tract obstruction: An update and insights from the national inpatient sample from 2011 to 2019
Inestroza, Karla , Mijares-Rojas, Ivan, Matute-Martínez, Carlos , Ergui, Ian , Vergara‐Sanchez, Carlos , Dangl, Michael , Hernandez, Rafael Jaciel, Vincent, Louis , Colombo, Rosario , Vergara-Sanchez, Carlos, Vergara Sanchez, Carlos A , Mijares-Rojas, Ivan A , Albosta, Michael Stanley , Hernandez, Rafael Jaciel , Ebner, Bertrand , Maning, Jennifer , Alfonso, Carlos

Journal of Investigative Medicine | January 7, 2024 | Volume: 72 | Issue: 3 | Pages: 262-269

10.1177/10815589241226959 Get It

Septal Myectomy (SM) and Alcohol Septal Ablation (ASA) improve symptoms in patients with Hypertrophic Cardiomyopathy with outflow tract obstruction (oHCM). However, outcomes data in this population is predominantly from specialized centers. The National Inpatient Database was queried from 2011 to 2019 for relevant international classification of diseases (ICD)-9 and -10 diagnostic and procedural codes. We compared baseline characteristics and in-hospital outcomes of patients with oHCM who underwent SM vs ASA. A p-value < 0.001 was considered statistically significant. We identified 15,119 patients with oHCM who underwent septal reduction therapies, of whom 57.4% underwent SM, and 42.6% underwent ASA. Patients who underwent SM had higher all-cause mortality (OR: 1.8 (1.3–2.5)), post-procedure ischemic stroke (OR: 2.3 (1.7–3.2)), acute kidney injury (OR: 1.4 (1.2–1.7)), vascular complications (OR: 3.6 (2.3–5.3)), ventricular septal defect (OR: 4.4 (3.2–6.1)), cardiogenic shock (OR: 1.7 (1.3–2.3)), sepsis (OR: 3.2 (1.9–5.4)), and left bundle branch block (OR: 3.5 (3–4)), compared to ASA. Patients who underwent ASA had higher post-procedure complete heart block (OR: 1.3 (1.1–1.4)), right bundle branch block (OR: 6.3 (5–7.7)), ventricular tachycardia (OR: 2.2 (1.9–2.6)), supraventricular tachycardia (OR: 1.6 (1.4–2)), and more commonly required pacemaker insertion (OR: 1.4 (1.3–1.7)) (p < 0.001 for all) compared to SM. This nationwide analysis evidenced that patients undergoing SM had higher in-hospital mortality and periprocedural complications than ASA; however, those undergoing ASA had more post-procedure conduction abnormalities and pacemaker implantation. The implications of these findings warrant further investigation regarding patient selection strategies for these therapies.
Food and Drug Administration Malfunction Recalls of Left Ventricular Assist Devices
Baruqui, Diego Lugo , Maning, Jennifer , Chaparro, Sandra , Lugo Baruqui, Diego

ASAIO Journal | February 24, 2020 | Volume: 66 | Issue: 7 | Pages: 739-745

10.1097/mat.0000000000001118 Get It

Left ventricular assist devices (LVADs) are being increasingly implanted given the increasing prevalence of patients with advanced heart failure stages. However, they are not exempt from device malfunctions. A PubMed search for the key words (left ventricular assist device malfunction) (ventricular assist system malfunction) was performed. We identified 28 publications in the US Food and Drug Administration (FDA) website database that addressed LVAD malfunction. Twenty-nine FDA recalls were identified regarding LVAD malfunctions: 17 regarding HeartWare ventricular assist device, six for HeartMate II, three for HeartMate 3, and three for total artificial heart. Mechanisms involved in LVAD malfunction include battery malfunction, loose driveline connector, malfunction of the system controller, loose power supply connector ports, malfunction of the driveline splice kit, problems with the percutaneous lead connection, disconnection of the bend relief and outflow graft and outflow graft occlusion among others. Multiple mechanisms could be linked to LVAD malfunction. However, multiple device modifications have been developed over the past decade to avoid recurrent malfunctions. Constant improvements and research in biotechnology are needed to prevent these complications. It remains to be seen if newer generation devices will lead to improved patient outcomes over the long term.