Three‐dimensional surface scanning of patients to extend computed tomography field of view and scan length for dose calculation and collision avoidance in radiotherapy treatment planning
Jackson, Amanda, Shrestha, Deepak K. , Johnson, Perry , Jackson, Amanda M

Journal of Applied Clinical Medical Physics | November 11, 2025 | Volume: 26 | Issue: 11 | Pages: No page available

10.1002/acm2.70333 Get It

Abstract Background Radiotherapy treatment planning requires knowledge of a patient's anatomical surface for use in dose calculations, collision checks, or surface‐guided radiation therapy (SGRT). This information is usually obtained from a computed tomography (CT) scan which may encounter field‐of‐view (FOV) limitations or require additional radiation dose beyond the treatment area to capture the full patient habitus. Purpose This study demonstrates an affordable alternative solution to obtain a patient's surface information without CT or room mounted surface‐guidance imaging cameras for the purpose of detecting patient collisions and providing additional skin surface information needed for appropriate depth calculations of clipped FOV scans. Methods Three‐dimensional (3D) surface models of five patients were acquired immediately prior to CT simulation using an iPad Air 2 equipped with a Structure Sensor Pro and Monocle SS application. The 3D surfaces were manually registered to the CT images and nearest distances between CT surface and 3D surface were calculated. Nearest distance calculations were also performed with a 2 mm CT rind structure that excluded select regions not relevant to surface detection. To demonstrate the advantage of having additional scan length for clearance checks, a collision simulated plan was evaluated with a shortened CT scan length versus with additional 3D surface information. Results CT rind to 3D scan surface mean distances for each patient were 1.65 mm, 0.99 mm, −0.93 mm, −0.79 mm, and −1.53 mm with standard deviations of 6.51 mm, 6.71 mm, 3.38 mm, 2.84 mm, and 2.69 mm. Conclusion This study demonstrates the feasibility of an accessible low‐cost 3D surface scanning solution to supplement clipped field‐of‐view CT scans and reduce CT scan lengths by obtaining important patient surface data for improved calculation accuracy, treatment clearance checks, and SGRT.
AAPM WGPE report 394: Simulated error training for the physics plan and chart review
Johnson, Perry , Schubert, Leah , Kim, Grace Gwe‐Ya, Faught, Jacqueline, Buckey, C, Luk, Samuel M. H. , Parker, S. , Conroy, Leigh , Schofield, Deborah

Medical Physics | April 8, 2024 | Volume: 51 | Issue: 5 | Pages: 3165-3172

10.1002/mp.17051 Get It

AbstractBackgroundSimulated error training is a method to practice error detection in situations where the occurrence of error is low. Such is the case for the physics plan and chart review where a physicist may check several plans before encountering a significant problem. By simulating potentially hazardous errors, physicists can become familiar with how they manifest and learn from mistakes made during a simulated plan review.PurposeThe purpose of this project was to develop a series of training datasets that allows medical physicists and trainees to practice plan and chart reviews in a way that is familiar and accessible, and to provide exposure to the various failure modes (FMs) encountered in clinical scenarios.MethodsA series of training datasets have been developed that include a variety of embedded errors based on the risk‐assessment performed by American Association of Physicists in Medicine (AAPM) Task Group 275 for the physics plan and chart review. The training datasets comprise documentation, screen shots, and digital content derived from common treatment planning and radiation oncology information systems and are available via the Cloud‐based platform ProKnow.ResultsOverall, 20 datasets have been created incorporating various software systems (Mosaiq, ARIA, Eclipse, RayStation, Pinnacle) and delivery techniques. A total of 110 errors representing 50 different FMs were embedded with the 20 datasets. The project was piloted at the 2021 AAPM Annual Meeting in a workshop where participants had the opportunity to review cases and answer survey questions related to errors they detected and their perception of the project's efficacy. In general, attendees detected higher‐priority FMs at a higher rate, though no correlation was found between detection rate and the detectability of the FMs. Familiarity with a given system appeared to play a role in detecting errors, specifically when related to missing information at different locations within a given software system. Overall, 96% of respondents either agreed or strongly agreed that the ProKnow portal and training datasets were effective as a training tool, and 75% of respondents agreed or strongly agreed that they planned to use the tool at their local institution.ConclusionsThe datasets and digital platform provide a standardized and accessible tool for training, performance assessment, and continuing education regarding the physics plan and chart review. Work is ongoing to expand the project to include more modalities, radiation oncology treatment planning and information systems, and FMs based on emerging techniques such as auto‐contouring and auto‐planning.
CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy
Reiners, Keaton, Dagan, Roi , Holtzman, Adam L. , Bryant, Curtis, Andersson, Sebastian, Nilsson, Rasmus , Hong, Liu, Johnson, Perry , Zhang, Yawei , Holtzman, Adam , Hong, Liu

Cancers | July 31, 2023 | Volume: 15 | Issue: 15 | Pages: 3881

10.3390/cancers15153881 Get It

Purpose: To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients. Methods: For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation. Results: Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively. Conclusion: Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.
Strategies for effective physics plan and chart review in radiation therapy: Report of AAPM Task Group 275
Ford, Eric , Santos, L Fong de los, Greener, Anne, Kim, Grace Gwe‐Ya, Johnson, Jennifer L. , Johnson, Perry , Napolitano, Brian, Parker, S. , Schofield, Deborah , Smith, Koren, Yorke, Ellen , Wells, Michelle, de Los Santos, Luis Fong, Conroy, Leigh , Dong, Lei , Santos, Luis E. Fong de los, Mechalakos, James

Medical Physics | January 22, 2020 | Volume: 47 | Issue: 6 | Pages: No page available

10.1002/mp.14030 Get It

Background While the review of radiotherapy treatment plans and charts by a medical physicist is a key component of safe, high‐quality care, very few specific recommendations currently exist for this task. Aims The goal of TG‐275 is to provide practical, evidence‐based recommendations on physics plan and chart review for radiation therapy. While this report is aimed mainly at medical physicists, others may benefit including dosimetrists, radiation therapists, physicians and other professionals interested in quality management. Methods The scope of the report includes photon/electron external beam radiotherapy (EBRT), proton radiotherapy, as well as high‐dose rate (HDR) brachytherapy for gynecological applications (currently the highest volume brachytherapy service in most practices). The following review time points are considered: initial review prior to treatment, weekly review, and end‐of‐treatment review. The Task Group takes a risk‐informed approach to developing recommendations. A failure mode and effects analysis was performed to determine the highest‐risk aspects of each process. In the case of photon/electron EBRT, a survey of all American Association of Physicists in Medicine (AAPM) members was also conducted to determine current practices. A draft of this report was provided to the full AAPM membership for comment through a 3‐week open‐comment period, and the report was revised in response to these comments. Results The highest‐risk failure modes included 112 failure modes in photon/electron EBRT initial review, 55 in weekly and end‐of‐treatment review, 24 for initial review specific to proton therapy, and 48 in HDR brachytherapy. A 103‐question survey on current practices was released to all AAPM members who self‐reported as working in the radiation oncology field. The response rate was 33%. The survey data and risk data were used to inform recommendations. Discussion Tables of recommended checks are presented and recommendations for best practice are discussed. Suggestions to software vendors are also provided. Conclusions TG‐275 provides specific recommendations for physics plan and chart review which should enhance the safety and quality of care for patients receiving radiation treatments.