Objectives: The purpose of this study was to evaluate the specificity and sensitivity of two red flag protocols in detecting ear diseases associated with changes in hearing. Design: The presence of red-flag symptoms was determined in a chart review of 307 adult patients from the Mayo Clinic Florida Departments of Otorhinolaryngology and Audiology. Participants formed a convenience sample recruited for a separate study. Neurotologist diagnosis was the criterion for comparisons. Results: Of the 251 patient files retained for analysis, 191 had one or more targeted diseases and 60 had age- or noise-related hearing loss. Food and Drug Administration red flags sensitivity was 91% (confidence interval [CI], 86 to 95%) and specificity was 72% (CI, 59 to 83%). American Academy of Otolaryngology-Head and Neck Surgery red flags sensitivity was 98% (CI, 95 to 99%) and specificity was 20% (CI, 11 to 32%). Conclusions: Stakeholders must determine which diseases are meaningful contraindications for hearing aid use and whether these red-flag protocols have acceptable levels of sensitivity and specificity. As direct-to-consumer models of hearing devices increase, a disease detection method that does not require provider intercession would be useful.
Development and Initial Validation of a Consumer Questionnaire to Predict the Presence of Ear Disease
Purpose The purpose of this research note is to identify and prioritize diseases important for detection in adult hearing health care delivery systems. Method Through literature review and expert consultation, the authors identified 195 diseases likely to occur in adults complaining of hearing loss. Five neurotologists rated the importance of disease on 3 dimensions related to the necessity of detection prior to adult hearing aid fitting. Results Ratings of adverse health consequences, diagnostic difficulty, and presence of nonotologic symptoms associated with these diseases resulted in the identification of 104 diseases potentially important for detection prior to adult hearing aid fitting. Conclusions Current and evolving health care delivery systems, including direct-to-consumer sales, involve inconsistent means of disease detection vigilance prior to device fitting. The first steps in determining the safety of these different delivery methods are to identify and prioritize which diseases present the greatest risk for poor health outcomes and, thus, should be detected in hearing health care delivery systems. Here the authors have developed a novel multidimensional rating system to rank disease importance. The rankings can be used to evaluate the effectiveness of alternative detection methods and to inform public health policy. The authors are currently using this information to validate a consumer questionnaire designed to accurately identify when pre- fitting medical evaluations should be required for hearing aid patients.
Novel radiology method for investigating middle ear myoclonus
Purpose Ocular vestibular evoked myogenic potentials (oVEMPs) are used to describe utricular/superior vestibular nerve function; however, optimal recording parameters have not been fully established. This study investigated the effect of repetition rate on air-conducted oVEMPs. Method Ten healthy adults were evaluated using 500-Hz tone bursts (4-ms duration, Blackman gating, 122 dB pSPL). Four repetition rates were used (1.6, 4.8, 8.3, and 26.6 Hz) and resulting oVEMP response presence, amplitude, amplitude asymmetry, and n1/p1 latency were assessed. Results Response presence was significantly reduced for 26.6 Hz using monaural stimulation and for 8.3 Hz and 26.6 Hz for binaural stimulation. For monaural stimulation using 1.6, 4.8, and 8.3 Hz, no significant differences were noted for amplitude or latency. Responses obtained using binaural stimulation demonstrated a significant effect of rate on amplitude, with 8.3 Hz producing significantly reduced amplitude. Binaural amplitudes were significantly larger than monaural contralateral responses but with reduced response presence. No significant differences were noted for latency or amplitude asymmetry. Conclusion Using repetition rates of approximately 5 Hz or less may produce more consistent oVEMP response presence with minimal effects on amplitude for monaural or binaural recordings.
Retrospective Analysis of Outcomes after Stapedotomy with Implantation of a Self‐Crimping Nitinol Stapes Prosthesis
OBJECTIVETo review hearing results after implantation of a self‐crimping stapes prosthesis.STUDY DESIGN AND SETTINGAnalysis of hearing results in patients implanted with a self‐crimping stapes prosthesis at two academic hospitals from 2000 to 2004.RESULTSSeventy‐nine ears were divided into short‐term and intermediate follow‐up groups. The mean postoperative air‐bone gap (ABG), preoperative minus postoperative ABG, and preoperative minus postoperative bone conduction values were 5.7, 21.4, and 4.1 dB, respectively, for the short‐term group, and 6.3, 22.3, and 4.7dB, respectively, for the intermediate group. The ABG was <10 dB in 88 percent of the short‐term group and in 79 percent of the intermediate group.CONCLUSIONSThe self‐crimping Nitinol stapes prosthesis provides excellent short‐term and intermediate postoperative hearing results, and may overcome the limitations of stapes prostheses requiring manual crimping.SIGNIFICANCEThis paper provides evidence for the use of a self‐crimping Nitinol stapes prosthesis, which may simplify hearing restoration surgery for stapes fixation.