Improvement in Blood Pressure Control in Safety Net Clinics Receiving 2 Versions of a Scalable Quality Improvement Intervention: BP MAP A Pragmatic Cluster Randomized Trial
Background Uncontrolled blood pressure (BP) remains a leading cause of death in the United States. The American Medical Association developed a quality improvement program to improve BP control, but it is unclear how to efficiently implement this program at scale across multiple health systems. Methods and Results We conducted BP MAP (Blood Pressure Measure Accurately, Act Rapidly, and Partner With Patients), a comparative effectiveness trial with clinic‐level randomization to compare 2 scalable versions of the quality improvement program: Full Support (with support from quality improvement expert) and Self‐Guided (using only online materials). Outcomes were clinic‐level BP control (<140/90 mm Hg) and other BP‐related process metrics calculated using electronic health record data. Difference‐in‐differences were used to compare changes in outcomes from baseline to 6 months, between intervention arms, and to a nonrandomized Usual Care arm composed of 18 health systems. A total of 24 safety‐net clinics in 9 different health systems underwent randomization and then simultaneous implementation. BP control increased from 56.7% to 59.1% in the Full Support arm, and 62.0% to 63.1% in the Self‐Guided arm, whereas BP control dropped slightly from 61.3% to 60.9% in the Usual Care arm. The between‐group differences‐in‐differences were not statistically significant (Full Support versus Self‐Guided=+1.2% [95% CI, −3.2% to 5.6%], P =0.59; Full Support versus Usual Care=+3.2% [−0.5% to 6.9%], P =0.09; Self‐Guided versus Usual Care=+2.0% [−0.4% to 4.5%], P =0.10). Conclusions In this randomized trial, 2 methods of implementing a quality improvement intervention in 24 safety net clinics led to modest improvements in BP control that were not statistically significant. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03818659.
Effectiveness of Standard vs Enhanced Self-measurement of Blood Pressure Paired With a Connected Smartphone Application
ImportanceSelf-measured blood pressure (SMBP) with commercially available connected smartphone applications may help patients effectively use SMBP measurements.ObjectiveTo determine if enhanced SMBP paired with a connected smartphone application was superior to standard SMBP for blood pressure (BP) reduction or patient satisfaction.Design, Setting, and ParticipantsThis randomized clinical trial was conducted among 23 health systems participating in PCORnet, the National Patient-Centered Clinical Research Network, and included patients who reported having uncontrolled BP at their last clinic visit, a desire to lower their BP, and a smartphone. Enrollment and randomization occurred from August 3, 2019, to December 31, 2020, which was followed by 6 months of follow-up for each patient. Analysis commenced shortly thereafter.InterventionsEligible participants were randomly assigned to enhanced SMBP using a device that paired with a connected smartphone application (enhanced) or a standard device (standard). Participants received their device in the mail, along with web-based educational materials and phone-based support as needed. No clinician engagement was undertaken, and the study provided no special mechanisms for delivering measurements to clinicians for use in BP management.Main Outcomes and MeasuresReduction in systolic BP, defined as the difference between clinic BP at baseline and the most recent clinic BP extracted from electronic health records at 6 months.ResultsEnrolled participants (1051 enhanced [50.0%] vs 1050 standard [50.0%]; 1191 women [56.7%]) were mostly middle-aged or older (mean [SD] age, 58 [13] years), nearly a third were Black or Hispanic (645 [31%]), and most were relatively comfortable using technology (mean [SD], 4.1 [1.1] of 5). The mean (SD) change in systolic BP from baseline to 6 months was −10.8 (18) mm Hg vs −10.6 (18) mm Hg (enhanced vs standard: adjusted difference, −0.19 mm Hg; 95% CI, −1.83 to 1.44;P = .81). Secondary outcomes were mostly null, except for documented attainment of BP control to lower than 140/&lt;90 mm Hg, which occurred in 32% enhanced vs 29% standard groups (odds ratio, 1.15; 95% CI, 1.01-1.34). Most participants were very likely to recommend their SMBP device to a friend (70% vs 69%).Conclusions and RelevanceThis randomized clinical trial found that enhanced SMBP paired with a smartphone application is not superior to standard SMBP for BP reduction or patient satisfaction.Trial RegistrationClinicalTrials.gov Identifier:NCT03796689
Background: Uncontrolled blood pressure (BP) is a leading preventable cause of death that remains common in the US population despite the availability of effective medications. New technology and program innovation has high potential to improve BP but may be expensive and burdensome for patients, clinicians, health systems, and payers and may not produce desired results or reduce existing disparities in BP control. Methods and Results: The PCORnet Blood Pressure Control Laboratory is a platform designed to enable national surveillance and facilitate quality improvement and comparative effectiveness research. The platform uses PCORnet, the National Patient-Centered Clinical Research Network, for engagement of health systems and collection of electronic health record data, and the Eureka Research Platform for eConsent and collection of patient-reported outcomes and mHealth data from wearable devices and smartphones. Three demonstration projects are underway: BP track will conduct national surveillance of BP control and related clinical processes by measuring theory-derived pragmatic BP control metrics using electronic health record data, with a focus on tracking disparities over time; BP MAP will conduct a cluster-randomized trial comparing effectiveness of 2 versions of a BP control quality improvement program; BP Home will conduct an individual patient-level randomized trial comparing effectiveness of smartphone-linked versus standard home BP monitoring. Thus far, BP Track has collected electronic health record data from over 826 000 eligible patients with hypertension who completed ≈3.1 million ambulatory visits. Preliminary results demonstrate substantial room for improvement in BP control (<140/90 mm Hg), which was 58% overall, and in the clinical processes relevant for BP control. For example, only 12% of patients with hypertension with a high BP measurement during an ambulatory visit received an order for a new antihypertensive medication. Conclusions: The PCORnet Blood Pressure Control Laboratory is designed to be a reusable platform for efficient surveillance and comparative effectiveness research; results from demonstration projects are forthcoming.
Abstract P2050: The Pcornet Blood Pressure Control Laboratory
Background: New technology and healthcare delivery approaches may help improve blood pressure (BP) control. Randomized controlled trials (RCTs) can demonstrate effectiveness of these emerging approaches, both overall and especially within underserved populations, but RCTs are expensive. Our objective is to establish a national platform to support BP control surveillance and efficient RCTs. Methods: The PCORnet BP Control Laboratory, designed and launched in partnership with the American Heart Association (AHA) and the American Medical Association (AMA), leverages electronic health record (EHR) systems throughout the US, the National Patient-Centered Outcomes Research Network (PCORnet), and the NIH-funded Eureka Research Platform, which enables direct-to-participant research including collection of patient-reported outcomes and mHealth data from wearable devices and smartphones. We will use these resources to 1) Conduct national surveillance through quarterly EHR data queries to calculate and track institution- and clinic-level BP control metrics across 23 PCORnet institutions, overall and within key subgroups, and support participation in the AHA/AMA’s Target:BP recognition program (BP Track); 2) Compare effectiveness of a Full Support versus Self-Guided version of the AMA’s Measure Accurately, Act Rapidly, and Partner with Patients (MAP) program at improving BP control in a cluster randomized trial of 24 safety net clinics (BP MAP); and 3) Compare effectiveness of Smartphone-linked versus standard home BP monitoring at reducing systolic BP in an individual-level, direct-to-participant RCT of 2000 patients with uncontrolled BP (BP Home). Results: Preliminary BP Track queries demonstrate an overall BP control rate of 56%, lower control in Black patients (51%), substantial heterogeneity in clinic-level metrics (e.g., 33% vs. 64% BP control), and low rates of medication intensification (9% prescribed a new medication class when BP was high). BP Track will launch PCORnet-wide queries in June; BP MAP in May; and BP Home in August 2019. Conclusions: Feasibility testing is underway to determine if the PCORnet BP Control Laboratory will be useful for investigators interested in conducting efficient RCTs of BP control interventions.