Back to Authors

Daxon, Benjamin T.

https://orcid.org/0000-0003-0244-5081

Mayo Clinic

Mayo Clinic

Citations 7

Airway Pressure Release Ventilation with a Time-Controlled Adaptive Ventilation Strategy (APRV-TCAV) Reverses Endotracheal Secretion Movement Compared with Volume-Control Ventilation: A Bench Study
Daxon, Benjamin T. , LeTourneau, William M. , Wanta, Brendan T., Bennett, Mariah L., DAWOOD, ABIER M., Stewart, Rylee N., McEleney, Pia P., Daxon, Ben T , Bennett, Mariah, Stewart, Rylee N, McEleney, Pia P

Journal of Clinical Medicine | August 10, 2026 | Volume: 15 | Issue: 16 | Pages: 6176

10.3390/jcm15166176 Get It

Background/Objectives: Retained airway secretions are a common complication of mechanical ventilation and a major contributor to ventilator-associated pneumonia. Airway Pressure Release Ventilation following a Time-Controlled Adaptive Ventilation protocol (APRV-TCAV) has been anecdotally observed to improve secretion clearance, but the mechanism is not well established. Because TCAV sets the release time (TLow) from each patient’s own expiratory flow decay, we hypothesized that the resulting expiratory-dominant flow profile would generate a net antegrade force on secretions. This bench study compared secretion movement between APRV-TCAV and conventional Volume-Control Continuous Mandatory Ventilation (VC-CMV), with and without an in-line oscillatory device. Methods: A critical care ventilator was connected to a 3 L test lung via a 7 mm endotracheal tube (ETT). Simulated mucus (1% guar gum) was instilled into the ETT, and secretion movement was measured under VC-CMV (positive end-expiratory pressure (PEEP) 5, 10, 15 cmH2O) and APRV-TCAV (PHigh 20, 25, 30 cmH2O; PLow 0 cmH2O). Each condition was repeated with an in-line oscillatory device. Results: All VC-CMV settings produced retrograde secretion movement toward the test lung; all APRV-TCAV settings produced antegrade movement. The largest antegrade movement was observed at the widest PHigh-to-PLow differential. Adding the oscillatory device raised peak expiratory flow above peak inspiratory flow in every condition, yet abolished antegrade movement under APRV-TCAV. Conclusions: In this bench study, APRV-TCAV reversed the direction of secretion movement within the ETT, with larger antegrade movement at wider PHigh-to-PLow differentials. This suggests a potential mechanism by which the ventilator flow profile itself may influence secretion movement. The directional effect depended on the intact release-phase waveform and was abolished by in-line oscillatory therapy despite preserved peak flow asymmetry.
Secretion Clearance in the Endotracheal Tube Is Influenced by Expiratory Flow and Breath Delivery Profile
McEleney, Pia P, Abdi, Nawal S, Bennett, Mariah, DAWOOD, ABIER M., Stewart, Rylee N, Warsame, Faisa G, LeTourneau, William Michael, Daxon, Benjamin T. , LeTourneau, William M.

Respiratory Care | March 12, 2026 | Volume: 69 | Issue: 10_suppl | Pages: 4137429-4137429

10.4187/respcare.20244137429 Get It

Meeting Report: Inaugural Introduction to Clinical Research for Academic Anesthesiologists Course
Rolfzen, Megan L. , Li, Fei , Zhu, Alyssa C. , Daxon, Benjamin T. , Walpole, Joseph , Li, Flora, Singla, Priyanka

A&A Practice | November 7, 2025 | Volume: 19 | Issue: 11 | Pages: e02087

10.1213/xaa.0000000000002087 Get It

The first Introduction to Clinical Research for Academic Anesthesiologists (ICRAA) Course took place from July 2024 through April 2025 via online interactive lectures. The 9-month course provided participants with the skills necessary to ethically design research proposals and conduct research projects. Some of the core principles taught included basics of biostatistics, ways to effectively communicate ideas to data analysts, how to write a grant, and tips on writing and analyzing scientific articles. In this report, we summarize the motivation, describe the content, and provide future directions for this initiative, which aims to foster high-quality clinical research among the next generation of academic anesthesiologists.
Single-Plane Versus Synchronous Biplane Ultrasound Imaging During Vascular Access Procedures: Which Is Better and How Can We Improve?
Anderson, Robert J., Daxon, Benjamin T. , Merren, Michael P.

Journal of the Association for Vascular Access | September 18, 2024 | Volume: 29 | Issue: 3 | Pages: 42-47

10.2309/java-d-24-00005 Get It

Highlights Biplane ultrasound imaging reduces need for probe manipulation during procedure. Providers note clinical benefit of biplane ultrasound imaging for vascular access. Biplane disadvantages include probe size, imaging quality, size of the screen. Thorough didactic and practical education is essential for biplane success. Abstract Background: Use of ultrasound guidance for vascular access procedures is commonplace in inpatient and outpatient care settings. Standard ultrasound probes offer the operator a single-plane view, necessitating rotation of probe to attain dual complimentary views. This mechanical probe rotation increases technical difficulty of ultrasound use. The purpose of this study is to evaluate the rate of cannulation success and efficiency of a synchronous biplane ultrasound mode in ultrasound-guided arterial line placement as compared with a standard single-view ultrasound mode in the operating room setting. Methods: Patients scheduled for elective surgery in which a radial arterial catheter would be used for hemodynamic monitoring were approached for consent to this study. Patients were randomized to either undergo placement with single-plane view versus synchronous biplane view; outcomes were recorded. Providers were provided preprocedural ultrasound education as well as the option of a short hands-on experience; their level of experience was noted. Results: Placement time of a peripheral arterial catheter was longer and required more attempts to be successful using synchronous biplane imaging as compared with single-plane imaging across providers of all skill/experience levels. Subjectively, providers noted the benefit of synchronous biplane imaging in vascular access; however, disadvantages including probe size, quality of imaging, and size of the screen were noted. Discussion: Thorough education regarding the use and functionality of biplane synchronous imaging in vascular access is essential. Additional guided-practice time with experienced operators could also be helpful to overcome the challenges observed in this study.
Nebulized Nitroglycerin for Coronavirus Disease 2019–Associated Acute Respiratory Distress Syndrome: A Case Report
Daxon, Benjamin T. , Lark, Erin, Matzek, Luke J. , Fields, Amanda R., Haselton, Kyle J., Daxon, Ben T

A&A Practice | February 21, 2021 | Volume: 15 | Issue: 2 | Pages: e01376

10.1213/xaa.0000000000001376 Get It

We present a case where nitroglycerin tablets dissolved in saline and intravenous nitroglycerin solution were nebulized as surrogates for inhaled nitric oxide (iNO) after our iNO supply was depleted during the coronavirus disease 2019 (COVID-19) surge in New York. We gave this treatment to a COVID-19 patient with severe acute respiratory distress syndrome (ARDS) and hypercarbia. In response, the patient had immediate and clinically meaningful improvement in multiple organ systems despite no other interventions or ventilator changes.
Severe Perioperative Hypoxemic Respiratory Failure
Daxon, Benjamin T.

A48. CRITICAL CARE CASE REPORTS: CAUSES AND COMPLICATIONS OF ACUTE RESPIRATORY FAILURE | August 26, 2019 | Volume: No volume available | Issue: No issue available | Pages: A1763-A1763

10.1164/ajrccm-conference.2019.199.1_meetingabstracts.a1763 Get It

Concerns over Airway Pressure Release Ventilation Management in Children with Acute Respiratory Distress Syndrome
Daxon, Ben, Daxon, Benjamin T.

American Journal of Respiratory and Critical Care Medicine | August 27, 2018 | Volume: 198 | Issue: 11 | Pages: 1458-1459

10.1164/rccm.201806-1164le Get It