PurposeTo evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues.MethodsMRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron‐based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same‐day test–retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland–Altman analysis.ResultsThe intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2. Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test–retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2 > 0.840).ConclusionProstate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.
Repeatability and reproducibility of 3D MR fingerprinting relaxometry measurements in normal breast tissue
BackgroundThe 3D breast magnetic resonance fingerprinting (MRF) technique enables T1 and T2 mapping in breast tissues. Combined repeatability and reproducibility studies on breast T1 and T2 relaxometry are lacking.PurposeTo assess test–retest and two‐visit repeatability and interscanner reproducibility of the 3D breast MRF technique in a single‐institution setting.Study TypeProspective.SubjectsEighteen women (median age 29 years, range, 22–33 years) underwent Visit 1 scans on scanner 1. Ten of these women underwent test–retest scan repositioning after a 10‐minute interval. Thirteen women had Visit 2 scans within 7–15 days in same menstrual cycle. The remaining five women had Visit 2 scans in the same menstrual phase in next menstrual cycle. Five women were also scanned on scanner 2 at both visits for interscanner reproducibility.Field Strength/SequenceTwo 3T MR scanners with the 3D breast MRF technique.AssessmentT1 and T2 MRF maps of both breasts.Statistical TestsMean T1 and T2 values for normal fibroglandular tissues were quantified at all scans. For variability, between and within‐subjects coefficients of variation (bCV and wCV, respectively) were assessed. Repeatability was assessed with Bland–Altman analysis and coefficient of repeatability (CR). Reproducibility was assessed with interscanner coefficient of variation (CoV) and Wilcoxon signed‐rank test.ResultsThe bCV at test–retest scans was 9–12% for T1, 7–17% for T2, wCV was <4% for T1, and <7% for T2. For two visits in same menstrual cycle, bCV was 10–15% for T1, 13–17% for T2, wCV was <7% for T1 and <5% for T2. For two visits in the same menstrual phase, bCV was 6–14% for T1, 15–18% for T2, wCV was <7% for T1, and <9% for T2. For test–retest scans, CR for T1 and T2 were 130 msec and 11 msec. For two visit scans, CR was <290 msec for T1 and 10–14 msec for T2. Interscanner CoV was 3.3–3.6% for T1 and 5.1–6.6% for T2, with no differences between interscanner measurements (P = 1.00 for T1, P = 0.344 for T2).Data Conclusion3D breast MRF measurements are repeatable across scan timings and scanners and may be useful in clinical applications in breast imaging.Level of Evidence: 2Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;50:1133–1143.