Back to Authors

Deckey, David G.

https://orcid.org/0000-0001-7374-5001

Mayo Clinic

Mayo Clinic

Citations 36

Prevalence, Biomechanics, and Pathologies of the Meniscofemoral Ligaments: A Systematic Review
Deckey, David G. , Tummala, Sailesh V. , Verhey, Jens T. , Hassebrock, Jeffrey D. , Dulle, Donald L., Miller, Mark D. , Chhabra, Anikar , Tummala, Sailesh, Dulle, Donald, Chhabra, Anikar , Hassebrock, Jeffrey D , Tummala, Sailesh V

Arthroscopy, Sports Medicine, and Rehabilitation | November 26, 2021 | Volume: 3 | Issue: 6 | Pages: No page available

10.1016/j.asmr.2021.09.006 Get It

Purpose To systematically review the literature to examine current understanding of the meniscofemoral ligaments (MFLs), their function, their importance in clinical management, and known anatomical variants. Methods A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta‐Analyses guidelines using PubMed, EMBASE, and Cochrane databases. Studies were included if they reported on the biomechanical, radiographic, or arthroscopic evaluation of human MFLs, or if they reported on an anatomical variant. These were then categorized as cadaveric, radiographic, or clinical. Biomechanical, radiographic, patient‐reported, and functional outcomes data were recorded. Results Forty‐seven studies were included in the qualitative analysis, and 26 of them were included in the quantitative analysis. Of these, there were 15 cadaveric, 3 arthroscopic, and 9 radiographic studies that reported on the prevalence of MFLs. Overall, when looking at all modalities, the presence of either the anterior or posterior MFL (aMFL, pMFL) has been noted to be 70.8%, with it being the aMFL 17.4% and the pMFL 40.6%. The presence of both ligaments occurs in approximately 17.6% of individuals. Eleven reported on mean MFL length and thickness. When evaluating mean length in both men and women, the aMFL has been reported between 21.6 and 28.3 mm and the pMFL length in this population is between 23.4 and 31.2 mm. Five reported on cross‐sectional area. Nine additional papers report anatomical variants. Conclusions This review shows that there continues to be a variable incidence of MFLs reported in the literature, but our understanding of their function continues to broaden. A growing number of anatomic and biomechanical studies have demonstrated the importance of the MFLs in supporting knee stability. Specifically, the MFLs serve an important role in protecting the lateral meniscus and augmenting the function of the posterior cruciate ligament. Clinical Relevance Our findings will aid the clinician in both identifying and treating pathologies of the meniscofemoral ligaments.
A novel meniscofemoral ligament variant intra‐substance to the PCL
Verhey, Jens T. , Deckey, David G. , Dulle, Donald L., Long, Jeremiah R. , Miller, Mark D. , Tummala, Sailesh, Hassebrock, Jeffrey D. , Dulle, Donald, Tummala, Sailesh V , Tummala, Sailesh V. , Chhabra, Anikar

Knee Surgery, Sports Traumatology, Arthroscopy | November 3, 2021 | Volume: 30 | Issue: 7 | Pages: 2277-2280

10.1007/s00167-021-06791-6 Get It

AbstractWhile much detail is known about each anatomic structure of the knee and its contributory effect on biomechanics, our understanding is still evolving. In particular, the function of the meniscofemoral ligaments and their anatomical variants have yet to be fully described. In this report, a never‐before‐described anatomical meniscofemoral ligament variant intra‐substance to the PCL is presented. Arthroscopists should be aware of the novel variant as a growing number of studies have demonstrated the biomechanical importance of the meniscofemoral ligaments in protecting the lateral meniscus and supporting the function of the PCL.Level of Evidence: IV.
Pediatric Extramedullary Epidural Spinal Teratomas: A Case Report and Review of the Literature
Deckey, David G. , Fernandez, Andrea, Lara, Nina , McClendon, Jamal, Bennett, David M. , Lara, Nina J , Bennett, David M , Taylor, Steve

Case Reports in Orthopedics | October 8, 2021 | Volume: 2021 | Issue: No issue available | Pages: 1-8

10.1155/2021/6702972 Get It

Background. Teratomas in the pediatric population are most commonly found in the sacrococcygeal region. Pediatric intraspinal teratomas, however, are an exceedingly rare central nervous system (CNS) neoplasm. The clinical presentation of these intraspinal neoplasms can vary significantly and thus can be difficult to identify in infants less than one year of age where verbal expression and motor development are still lacking. Case Description. A 7-month-old, previously healthy male presented with a thoracic scoliosis and an asymptomatic right midupper thoracic spinal prominence present since birth. MRI revealed an extensive heterogenous mass in the right epidural space from T5-T6 and the right paravertebral space, resulting in severe spinal stenosis. Outcome. Complete resection of the tumor, including a three-level neurotomy, was achieved by posterior decompression/laminectomy. The final tumor was consistent with a mature teratoma. The surgical resection was performed without any immediate complications. Conclusions. Extramedullary epidural teratomas are exceptionally rare tumors in the pediatric population. Clinical presentation can be ambiguous, particularly in an infant. MRI was useful in suggesting a teratoma as a potential diagnosis and for postoperative surveillance for recurrence. However, histopathological analysis remains the gold standard for definitive diagnosis. Surgical resection is the mainstay of treatment, especially in the setting of cord compression and progressive loss of motor function. Close follow-up is crucial to monitor for progressive spinal deformity or recurrence.
30-Day Outcomes for Total Ankle Arthroplasty in Patients With Anemia
Pollock, Jordan R. , Doan, Matt K., Moore, M. Lane , Makovicka, Justin L. , Deckey, David G. , Kile, Todd A. , Hassebrock, Jeffrey D. , Moore, M Lane , Pollock, Jordan Riley , Doan, Matthew K. , Patel, Karan A.

Foot & Ankle International | June 10, 2021 | Volume: 42 | Issue: 11 | Pages: 1463-1468

10.1177/10711007211017512 Get It

Background: While anemia has been associated with poor surgical outcomes in total knee arthroplasty and total hip arthroplasty, the effects of anemia on total ankle arthroplasty remain unknown. This study examines how preoperative anemia affects postoperative outcomes in total ankle arthroplasty. Methods: A retrospective analysis was performed using the American College of Surgeons National Surgery Quality Improvement Project database from 2011 to 2018 for total ankle arthroplasty procedures. Hematocrit (HCT) levels were used to determine preoperative anemia. Results: Of the 1028 patients included in this study, 114 patients were found to be anemic. Univariate analysis demonstrated anemia was significantly associated with an increased average hospital length of stay (2.2 vs 1.8 days, P < .008), increased rate of 30-day readmission (3.5% vs 1.1%, P = .036), increased 30-day reoperation (2.6% vs 0.4%, P = .007), extended length of stay (64% vs 49.9%, P = .004), wound complication (1.75% vs 0.11%, P = .002), and surgical site infection (2.6% vs 0.6%, P = .017). Multivariate logistic regression analysis found anemia to be significantly associated with extended hospital length of stay (odds ratio [OR], 1.62; 95% CI, 1.07-2.45; P = .023) and increased reoperation rates (OR, 5.47; 95% CI, 1.15-26.00; P = .033). Anemia was not found to be a predictor of increased readmission rates (OR, 3.13; 95% CI, 0.93-10.56; P = .066) or postoperative complications (OR, 1.27; 95% CI, 0.35-4.56; P = .71). Conclusion: This study found increasing severity of anemia to be associated with extended hospital length of stay and increased reoperation rates. Providers and patients should be aware of the increased risks of total ankle arthroplasty with preoperative anemia. Level of Evidence: Level III, retrospective comparative study.
Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques
Deckey, David G. , Rosenow, Christian S. , Verhey, Jens T. , Brinkman, Joseph C. , Mayfield, Cory K. , Clarke, Henry D. , Bingham, Joshua S.

The Bone & Joint Journal | May 31, 2021 | Volume: 103-B | Issue: 6 Supple A | Pages: 74-80

10.1302/0301-620x.103b6.bjj-2020-2003.r1 Get It

Aims Robotic-assisted total knee arthroplasty (RA-TKA) is theoretically more accurate for component positioning than TKA performed with mechanical instruments (M-TKA). Furthermore, the ability to incorporate soft-tissue laxity data into the plan prior to bone resection should reduce variability between the planned polyethylene thickness and the final implanted polyethylene. The purpose of this study was to compare accuracy to plan for component positioning and precision, as demonstrated by deviation from plan for polyethylene insert thickness in measured-resection RA-TKA versus M-TKA. Methods A total of 220 consecutive primary TKAs between May 2016 and November 2018, performed by a single surgeon, were reviewed. Planned coronal plane component alignment and overall limb alignment were all 0° to the mechanical axis; tibial posterior slope was 2°; and polyethylene thickness was 9 mm. For RA-TKA, individual component position was adjusted to assist gap-balancing but planned coronal plane alignment for the femoral and tibial components and overall limb alignment remained 0 ± 3°; planned tibial posterior slope was 1.5°. Mean deviations from plan for each parameter were compared between groups for positioning and size and outliers were assessed. Results In all, 103 M-TKAs and 96 RA-TKAs were included. In RA-TKA versus M-TKA, respectively: mean femoral positioning (0.9° (SD 1.2°) vs 1.7° (SD 1.1°)), mean tibial positioning (0.3° (SD 0.9°) vs 1.3° (SD 1.0°)), mean posterior tibial slope (-0.3° (SD 1.3°) vs 1.7° (SD 1.1°)), and mean mechanical axis limb alignment (1.0° (SD 1.7°) vs 2.7° (SD 1.9°)) all deviated significantly less from the plan (all p < 0.001); significantly fewer knees required a distal femoral recut (10 (10%) vs 22 (22%), p = 0.033); and deviation from planned polyethylene thickness was significantly less (1.4 mm (SD 1.6) vs 2.7 mm (SD 2.2), p < 0.001). Conclusion RA-TKA is significantly more accurate and precise in planning both component positioning and final polyethylene insert thickness. Future studies should investigate whether this increased accuracy and precision has an impact on clinical outcomes. The greater accuracy and reproducibility of RA-TKA may be important as precise new goals for component positioning are developed and can be further individualized to the patient. Cite this article: Bone Joint J 2021;103-B(6 Supple A):74–80.
Does Laterality Matter? The Effect of Unilateral v. Bilateral Sacroiliac Screw Fixation on Personal Hygiene
Deckey, David G. , Gulbrandsen, Matthew T. , Hinckley, Nathaniel B. , Lara, Nina , Mayfield, Cory K. , Makovicka, Justin L. , Adeniyi, Biodun, Lara, Nina J , Chang, Michael S.

Global Spine Journal | May 18, 2021 | Volume: 13 | Issue: 4 | Pages: 1036-1041

10.1177/21925682211015675 Get It

Study Design: Retrospective comparative analysis of prospective cohort. Objective: To determine whether sacroiliac (SI) screw fixation ipsilateral to hand dominance compared to bilateral fixation impacts personal hygiene (wiping) after toileting. Methods: Inclusion criteria were adult spinal deformity (ASD) patients with long arthrodesis (≥T12-pelvis) who had undergone primary unilateral or bilateral SI fixation with a minimum of 2-years-follow-up. Results: 117 consecutive patients were included and separated into 2 groups: bilateral SI fixation (BL, n = 61) and unilateral SI fixation (UNI, n = 56), with no difference in age. Of UNI patients, 10.7% (6) performed personal hygiene with a different hand after surgery, compared to 6.6% (4) of patients who received BL fixation ( P = 0.422). All UNI patients who switched hands were right-hand dominant, and 5/6 received right-sided fixation. There was no statistical difference found between number of levels fused (<8, 9-11, or >11 levels) and changes in personal hygiene habits. Over a third of patients from both groups had difficulty performing personal hygiene after fusion (UNI = 39.3% BL = 36.1%, P = 0.719). Conclusion: SI screws increase the difficulty of performing personal hygiene; yet, the side of unilateral screws does not significantly change personal hygiene habits when compared to bilateral screw placement. Moreover, the length of the construct does not have a significant impact on ability to perform personal hygiene, cause changes in habits, or require the assistance of another individual. However, among our sample of individuals, bilateral fixation did result in a higher rate of revision instrumentation.
Primary Tritanium acetabular components have increased rates of radiolucency associated with inferior clinical outcomes at short-term follow-up
Hinckley, Nathaniel B. , Deckey, David G. , Hines, Jeremy T. , Bingham, Joshua S. , Deckey, David G , Hines, Jeremy, Spangehl, Mark J.

HIP International | February 13, 2021 | Volume: 32 | Issue: 6 | Pages: 724-729

10.1177/1120700020988723 Get It

Introduction: Cementless fixation is the standard for acetabular fixation in primary total hip arthroplasty (THA). There are various surface finishes thought to improve osteointegration, although literature regarding the long-term survival of some of these surfaces is limited. Regardless of design, primary stability is essential to allow for osteointegration. Previous studies have suggested an increased rate of radiolucency and compromised short-term functional outcomes using the Tritanium primary acetabular component (Stryker, Mahwah, NJ). The purpose of this study was to compare the primary Tritanium acetabular component to another contemporary acetabular component as a control group with an established clinical record. Methods: 444 consecutive, primary THAs performed by a single surgeon from 2008 to 2012 were reviewed. Patients were included if they had a minimum 1-year follow-up. Implant survivorship and modified Harris Hip Scores (mHHS) were recorded for all patients at final follow-up. Radiographs were evaluated by 2 surgeons at 6 weeks, 1 year, and the most recent follow-up for evidence of radiolucency and migration. Components were considered to have evidence of radiographic lucency if they had radiolucency in 2 or more DeLee zones. Results: 198 patients met criteria for inclusion (96 Pinnacle, 102 Tritanium). Average follow-up was 28 (12–72) months. At final follow-up 6.2% of the Pinnacle cups and 29.4% of the Tritanium cups had radiographic evidence of loosening ( p < 0.01). The average mHHS for the Tritanium group was 83.1, and 88.4 for the Pinnacle group ( p < 0.01). Radiographic evidence of loosening also correlated with a lower mHHS: 75.5 versus 86.4 ( p < 0.01). In patients that received Tritanium cups without screw fixation 44.6% showed radiographic evidence of loosening versus 8% that received screw fixation ( p < 0.01). In total, 6 patients in the Tritanium group required revision for aseptic loosening of the acetabular component. Conclusions: The 30% rate of radiographic loosening in the Tritanium group was significantly higher than the Pinnacle group and correlated with an inferior clinical outcome. Interestingly the use of screw augmentation was protective against radiographic evidence of loosening. This suggests that the Tritanium component may be prone to fibrous in-growth because of inadequate primary stability.
A Comprehensive Analysis of Medicare Reimbursement to Physicians for Common Arthroscopic Procedures: Adjusted Reimbursement Has Fallen Nearly 30% From 2000 to 2019
Pollock, Jordan R. , Haglin, Jack M. , LeBlanc, Matthew P., Arthur, Jaymeson R. , Deckey, David G. , Chhabra, Anikar , Bingham, Joshua S. , Pollock, Jordan Riley , Chhabra, Anikar , Moore, M. Lane

Arthroscopy | December 2, 2020 | Volume: 37 | Issue: 5 | Pages: 1632-1638

10.1016/j.arthro.2020.11.049 Get It

Purpose To analyze and objectively measure the trends in inflation‐adjusted Medicare reimbursement rates for the 20 most commonly performed orthopaedic arthroscopic surgical procedures from 2000 to 2019. Methods The Centers for Medicare & Medicaid Services website was used to find the top 20 most commonly performed arthroscopic procedures using the Public Use File data file for calendar year 2017. By use of the Physician Fee Schedule Look‐Up Tool, national reimbursement averages were calculated from 2000‐2019 and data were analyzed. Averages were adjusted for inflation using the Consumer Price Index. Current Procedural Terminology codes that did not exist in 2000 were unable to be analyzed in this study. Results When adjusted for inflation, Medicare reimbursement for the 20 most commonly performed arthroscopic procedures from 2000‐2019 has decreased substantially (–29.81%). The mean Medicare reimbursement to physicians was $906 in 2000 and $632 in 2019. During this same period, the annual change in the adjusted mean reimbursement rate for all included arthroscopic procedures was –1.8% whereas the average compound annual growth rate was –1.9%. Conclusions This study shows that when adjusted for inflation, Medicare reimbursement to physicians has decreased by nearly 30% during the past 20 years for the most common arthroscopic procedures. Clinical Relevance This analysis will give orthopaedic surgeons and hospital administrators a better understanding of the financial trends surrounding one of the fastest‐growing techniques in surgery. Additionally, these financial‐trend data will be increasingly important as the population in the United States continues to age and new payment models are introduced.
Suture Stabilization of Open Physeal Fractures of the Great Toe Distal Phalanx (Seymour Fracture)
Reid, Daniel , Deckey, David G. , Procaccini, Michaela, Eberson, Craig P.

Journal of Pediatric Orthopaedics | October 7, 2020 | Volume: 41 | Issue: 1 | Pages: 51-55

10.1097/bpo.0000000000001632 Get It

Background: Open physeal fractures of the distal phalanx of the hallux are analogous to Seymour fractures of the hand. When missed, these injuries can result in long-term sequelae including infection, pain, nail deformity, and physeal arrest. Nevertheless, there is a paucity in the literature regarding optimal surgical treatment for these challenging injuries. We present a novel technique and case series for suture-only stabilization of Seymour fractures of the great toe. Methods: Billing records were used to identify all children aged 18 years or younger who underwent operative treatment open distal phalanx fracture of the hallux with an associated nail bed injury. Electronic medical records and plain imaging were reviewed to identify mechanism of injury, surgical technique, results, complications, and follow-up. Results: Five boys with a mean age of 10.3 years (range, 5 to 13 y) met inclusion criteria. Forty percent (2/5) of injuries were missed by the initial treating providers. Only 2 patients presented to our institution primarily; 60% (3/5) patients were transferred from other facilities. The mechanism of injury was variable but generally involved “stubbing” the toe. The mean time from injury to surgical treatment was 2.6 days (range, 0 to 6 d). Median follow-up was 2 months (range, 1 to 96 mo). No patient complications (including infection) or reoperations were reported. On follow-up imaging, no physeal bars were evident on patients treated with suture-only technique. Conclusions: Seymour fracture of the hallux are uncommon, and there is frequently a delay in both presentation and diagnosis. Providers should have increased suspicion for these injuries when a physeal fracture of the great toe is associated with bleeding or nail bed injury. Currently, no consensus exists for treatment of these injuries. Suture-only stabilization represents a simple, reliable alternative to pin fixation. Level of Evidence: Level IV—retrospective case series.
Hand and Wrist Injuries in Men’s and Women’s National Collegiate Athletic Association Basketball
Deckey, David G. , Scott, Kelly, Hinckley, Nathaniel B. , Makovicka, Justin L. , Pena, Austin, Asprey, Walker L., Scott, Kelly L, Hassebrock, Jeffrey D. , Asprey, Walker, Tummala, Sailesh V , Tummala, Sailesh V. , Chhabra, Anikar

Orthopaedic Journal of Sports Medicine | September 28, 2020 | Volume: 8 | Issue: 9 | Pages: No page available

10.1177/2325967120953070 Get It

Background: Hand and wrist injuries (HWIs) are common in National Collegiate Athletic Association (NCAA) basketball players and can negatively affect performance. There is limited literature available on this topic. Purpose: To open a discussion on prevention strategies and encourage future research on HWIs in basketball athletes. Study Design: Descriptive epidemiology study. Methods: HWIs sustained by male and female NCAA basketball players during the 2009-2010 through 2013-2014 academic years and reported to the NCAA Injury Surveillance Program (NCAA-ISP) database were utilized to characterize the epidemiology thereof. Rates and distributions of HWIs were identified within the context of mechanism of injury, injury recurrence, and time lost from sport. Results: Over the 5-year period, 81 HWIs in women and 171 HWIs in men were identified through the NCAA-ISP database. These were used to estimate 3515 HWIs nationally in women’s basketball athletes and 7574 HWIs nationally in men’s basketball athletes. The rate of HWIs in women was 4.20 per 10,000 athlete-exposures (AEs) and in men was 7.76 per 10,000 AEs, making men 1.85 times more likely to sustain HWIs compared with women. In men, HWIs were 3.31 times more likely to occur in competition compared with practice, while in women, HWIs were 2.40 times more likely to occur in competition than in practice. Based on position, guards, both men and women, were the most likely to suffer HWIs. Conclusion: HWIs were common in collegiate basketball players. Most injuries were new, and the majority of players were restricted from participation for less than 24 hours. Men were more likely to be injured compared with women, and injuries were most common in the setting of competition for both sexes. The majority of injuries was considered minor and did not extensively limit participation; however, prevention and detection remain important for optimal performance.