Back to Authors

Simmons, Debra L.

Mayo Clinic

University of Utah

Citations 2

Effect of Intensive and Standard Clinic‐Based Hypertension Management on the Concordance Between Clinic and Ambulatory Blood Pressure and Blood Pressure Variability in SPRINT
Ghazi, Lama , Bates, Jeffrey T. , Chang, Tara I. , Haley, William E. , Johnson, Karen, Kostis, William J. , Simmons, Debra L., Taylor, Addison A. , Whelton, Paul K. , Wright, Jackson T. , Bhatt, Udayan, Drawz, Paul E. , Johnson, Karen , Drawz, Paul , Pajewski, Nicholas M. , Rifkin, Dena E. , Cushman, William C. , Glasser, Stephen P. , Papademetriou, Vasilios , Rahman, Mahboob , Ghazi, Lama

Journal of the American Heart Association | July 16, 2019 | Volume: 8 | Issue: 14 | Pages: No page available

10.1161/jaha.118.011706 Get It

Background Blood pressure ( BP ) varies over time within individual patients and across different BP measurement techniques. The effect of different BP targets on concordance between BP measurements is unknown. The goals of this analysis are to evaluate concordance between (1) clinic and ambulatory BP , (2) clinic visit‐to‐visit variability and ambulatory BP variability, and (3) first and second ambulatory BP and to evaluate whether different clinic targets affect these relationships. Methods and Results The SPRINT (Systolic Blood Pressure Intervention Trial) ambulatory BP monitoring ancillary study obtained ambulatory BP readings in 897 participants at the 27‐month follow‐up visit and obtained a second reading in 203 participants 293±84 days afterward. There was considerable lack of agreement between clinic and daytime ambulatory systolic BP with wide limits of agreement in Bland‐Altman plots of −21 to 34 mm Hg in the intensive‐treatment group and −26 to 32 mm Hg in the standard‐treatment group. Overall, there was poor agreement between clinic visit‐to‐visit variability and ambulatory BP variability with correlation coefficients for systolic and diastolic BP all <0.16. We observed a high correlation between first and second ambulatory BP ; however, the limits of agreement were wide in both the intensive group (−27 to 21 mm Hg) and the standard group (−23 to 20 mm Hg). Conclusions We found low concordance in BP and BP variability between clinic and ambulatory BP and second ambulatory BP . Results did not differ by treatment arm. These results reinforce the need for multiple BP measurements before clinical decision making.
Abstract P171: Effect of Intensive and Standard Clinic-Based Hypertension Management on the Concordance Between Clinic and Ambulatory Blood Pressure and Blood Pressure Variability: Systolic Blood Pressure Intervention Trial (SPRINT)
Bates, Jeffrey T. , Chang, Tara I. , Cushman, Wlliam C, Haley, William E. , Johnson, Karen, Pinion, Mary, Simmons, Debra L., Whelton, Paul K. , Wright, Jackson T. , Ghazi, Lama , Pajewski, Nicholas M. , Rifkin, Dena E. , Glasser, Stephen P. , Kostis, William J. , Papademetriou, Vasilios , Rahman, Mahboob , Taylor, Addison A. , Drawz, Paul E.

Circulation | March 6, 2019 | Volume: 139 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.139.suppl_1.p171 Get It

Blood pressure (BP) varies over time within individual patients and across different BP measurement techniques. The effect of different BP targets on the concordance between BP measurements is unknown. The goal of this analysis was to evaluate concordance in: 1) clinic BP and ambulatory BP, 2) clinic visit-to-visit variability and ambulatory BP variability and 3) initial and repeat ambulatory BP. We also sought to evaluate whether treatment assignment of intensive vs standard BP target affected these relationships. The Systolic Blood Pressure Intervention Trial (SPRINT) ambulatory blood pressure monitoring ancillary study obtained ambulatory BP readings in 897 SPRINT participants at the 27 month follow up visit and 203 consecutive repeat ambulatory BP readings taken an average of 9.8 months later. There was poor agreement between clinic systolic BP and daytime ambulatory systolic BP (limits of agreement in Bland-Altman plots of -21 to 34 mm Hg in the intensive treatment group and -26 to 32 mm Hg in the standard treatment group). There was poor agreement between clinic visit-to-visit variability (coefficient of variation) and ambulatory BP variability (coefficient of variation of a 24 hr ambulatory BP) with correlation coefficients for systolic BP <0.16. While there was a high correlation between ambulatory BP at 27 months and repeat ambulatory BP (r ~0.56), there was significant variability between repeat ambulatory BP assessments (limits of agreement of -27 to 21 mm Hg in the intensive group and -23 to 20 mm Hg in the standard group). In conclusion, irrespective of treatment target, we found low concordance in BP and BP variability between clinic BP and ambulatory BP, and additionally between repeat ambulatory BP assessments. These results reinforce the need for multiple guideline adherent BP measurements prior to clinical decision making.