Back to Authors

Castillo, Richard

https://orcid.org/0000-0001-6541-6021

Mayo Clinic

Emory University

Citations 2

Functional avoidance‐based intensity modulated proton therapy with 4DCT derived ventilation imaging for lung cancer
Dougherty, Jingjing M. , Castillo, Edward , Faught, Austin M. , Pepin, M. , Beltran, Chris , Guerrero, Thomas , Grills, Inga S., Vinogradskiy, Yevgeniy , Pepin, Mark, Beltran, Chris J., Beltran, Chris J , Pepin, Mark D , Castillo, Richard , Park, Sean S.

Journal of Applied Clinical Medical Physics | June 23, 2021 | Volume: 22 | Issue: 7 | Pages: 276-285

10.1002/acm2.13323 Get It

Abstract The primary objective is to evaluate the potential dosimetric gains of performing functional avoidance‐based proton treatment planning using 4DCT derived ventilation imaging. 4DCT data of 31 patients from a prospective functional avoidance clinical trial were evaluated with intensity modulated proton therapy (IMPT) plans and compared with clinical volumetric modulated arc therapy (VMAT) plans. Dosimetric parameters were compared between standard and functional plans with IMPT and VMAT with one‐way analysis of variance and post hoc paired student t‐test. Normal Tissue Complication Probability (NTCP) models were employed to estimate the risk of two toxicity endpoints for healthy lung tissues. Dose degradation due to proton motion interplay effect was evaluated. Functional IMPT plans led to significant dose reduction to functional lung structures when compared with functional VMAT without significant dose increase to Organ at Risk (OAR) structures. When interplay effect is considered, no significant dose degradation was observed for the OARs or the clinical target volume (CTV) volumes for functional IMPT. Using fV20 as the dose metric and Grade 2+ pneumonitis as toxicity endpoint, there is a mean 5.7% reduction in Grade 2+ RP with the functional IMPT and as high as 26% in reduction for individual patient when compared to the standard IMPT planning. Functional IMPT was able to spare healthy lung tissue to avoid excess dose to normal structures while maintaining satisfying target coverage. NTCP calculation also shows that the risk of pulmonary complications can be further reduced with functional based IMPT.
Robust CT ventilation from the integral formulation of the Jacobian
Castillo, Edward , Castillo, Richard , Vinogradskiy, Yevgeniy , Solís, David , Myziuk, Nicholas , Thompson, A. , Guerra, Rudy, Guerrero, Thomas , Dougherty, Michele, Dougherty, M. K. , NAIR, GIRISH BALACHANDRAN

Medical Physics | February 19, 2019 | Volume: 46 | Issue: 5 | Pages: 2115-2125

10.1002/mp.13453 Get It

Computed tomography (CT) derived ventilation algorithms estimate the apparent voxel volume changes within an inhale/exhale CT image pair. Transformation‐based methods compute these estimates solely from the spatial transformation acquired by applying a deformable image registration (DIR) algorithm to the image pair. However, approaches based on finite difference approximations of the transformation's Jacobian have been shown to be numerically unstable. As a result, transformation‐based CT ventilation is poorly reproducible with respect to both DIR algorithm and CT acquisition method.PurposeWe introduce a novel Integrated Jacobian Formulation (IJF) method for estimating voxel volume changes under a DIR‐recovered spatial transformation. The method is based on computing volume estimates of DIR mapped subregions using the hit‐or‐miss sampling algorithm for integral approximation. The novel approach allows for regional volume change estimates that (a) respect the resolution of the digital grid and (b) are based on approximations with quantitatively characterized and controllable levels of uncertainty. As such, the IJF method is designed to be robust to variations in DIR solutions and thus overall more reproducible.MethodsNumerically, Jacobian estimates are recovered by solving a simple constrained linear least squares problem that guarantees the recovered global volume change is equal to the global volume change obtained from the inhale and exhale lung segmentation masks. Reproducibility of the IJF method with respect to DIR solution was assessed using the expert‐determined landmark point pairs and inhale/exhale phases from 10 four‐dimensional computed tomographies (4DCTs) available on www.dir-lab.com. Reproducibility with respect to CT acquisition was assessed on the 4DCT and 4D cone beam CT (4DCBCT) images acquired for five lung cancer patients prior to radiotherapy.ResultsThe ten Dir‐Lab 4DCT cases were registered twice with the same DIR algorithm, but with different smoothing parameter. Finite difference Jacobian (FDJ) and IFJ images were computed for both solutions. The average spatial errors (300 landmarks per case) for the two DIR solution methods were 0.98 (1.10) and 1.02 (1.11). The average Pearson correlation between the FDJ images computed from the two DIR solutions was 0.83 (0.03), while for the IJF images it was 1.00 (0.00). For intermodality assessment, the IJF and FDJ images were computed from the 4DCT and 4DCBCT of five patients. The average Pearson correlation of the spatially aligned FDJ images was 0.27 (0.11), while it was 0.77 (0.13) for the IFJ method.ConclusionThe mathematical theory underpinning the IJF method allows for the generation of ventilation images that are (a) computed with respect to DIR spatial accuracy on the digital voxel grid and (b) based on DIR‐measured subregional volume change estimates acquired with quantifiable and controllable levels of uncertainty. Analyses of the experiments are consistent with the mathematical theory and indicate that IJF ventilation imaging has a higher reproducibility with respect to both DIR algorithm and CT acquisition method, in comparison to the standard finite difference approach.