Abstract Disclosure: K. Yu: None. S. Athimulam: None. J. Saini: None. R. Kaur: None. R.J. Singh: None. S.K. Grebe: None. Q. Xue: None. I. Bancos: Advisory Board Member; Self; AstraZeneca, Corcept, Novo Nordisk, HRA Pharmaceuticals, Neurocrine, Diurnal, Recordati, Sparrow, Xeris, Spruce, Adrenas. Research Investigator; Self; HRA Pharmaceuticals, Recordati. Context: Early diagnosis is essential to assure a better prognosis in patients with adrenocortical carcinoma (ACC). Guidelines suggested performing urine steroid profiling in patients with indeterminate adrenal tumors to make a noninvasive diagnosis of ACC. However, urine steroid profiling is not widely available. Accuracy of clinically available serum steroids in diagnosing ACC has not been established. Objective: To determine the accuracy of 11-deoxycortisol, 17OH-progesterone, and 17OH-pregnenolone in diagnosing ACC. Design: Prospective single-center cohort study. Participants: Between 2015 and 2023, consecutive patients with adrenal mass were prospectively enrolled in the prospective registry and biobank study. Patients who agreed to contribute a fasting serum sample were included in the study. Exclusion criteria were congenital adrenal hyperplasia, exogenous glucocorticoid use, absence of unenhanced Hounsfield unit measurements (HU), and lack of established reference standard (histopathology, imaging characteristics, 2-year imaging follow up, or 5-year clinical follow up). Measures and Outcomes: measurements included 11-deoxycortisol, 17OH-progesterone, and 17OH-pregnenolone by liquid chromatography–mass spectrometry. Localized Generalized Matrix Learning Vector Quantization (LGMLVQ) analysis was used to develop serum steroid score and assessed with area under receiver operating curve (AUROC). Results: Of 263 patients with adrenal masses, 44 (17%) were diagnosed with ACC, 161 (61%) with adrenocortical adenomas (ACAs), 27 (10%) with other adrenal malignancies, and 31 (12%) with other. HU ≥ 20 were demonstrated in all ACCs, in all but one other adrenal malignancy, and only in 58 (31%) ACAs. All 3 steroids were higher in patients with ACCs vs nonACCs, including when comparing ACCs with functioning ACAs, and with ACAs with HU ≥ 20 (P<0.0001 for all). LGMLVQ analysis yielded a serum steroid score that discriminated between ACC and non-ACC groups with a mean threshold fixed AUROC of 0.823. Serum steroid score of 0.29 demonstrated a mean false negative rate of 0% and a score of 0.61 demonstrated a mean false positive rate of 0%. Conclusions: We showed that measurements of 11-deoxycortisol, 17OH-progesterone, and 17OH-pregnenolone could be valuable in diagnosing ACC. After appropriate validation, serum steroid score could be integrated in clinical practice. Presentation: 6/2/2024
B-150 Chromatographic Separation and Quantitation of Human Insulin and Lispro Analog in Serum Using Liquid Chromatography High-Resolution Mass Spectrometry
Abstract Background Factitious hypoglycemia, a deliberate attempt to induce low blood glucose levels occurring secondary to the surreptitious administration of exogenous insulin, can be difficult to diagnose due to a variety of factors including the increased use of synthetic insulin analogs in clinical practice. Traditional insulin immunoassays demonstrate variable cross-reactivity with commonly prescribed insulin analogues and their metabolites, making it difficult to measure specific analogs. The development of liquid chromatography high resolution accurate mass (LC-HRAM)-mass spectrometry (MS) assays has largely circumvented the limitations of traditional immunoassays for detection and quantitation of insulin analogs. Analytical challenges remain, however, specifically in differentiating lispro, an isomeric human insulin analog formed by the transposition of proline and lysine near the C-terminal end of the B chain, from human insulin in patient samples due to the equivalent mass-to-charge ratios of their precursor ions. Methods Immunoaffinity purification of insulin from calibrators and quality control material prepared by spiking insulin-depleted serum with pharmaceutical insulin preparations, as well as patient samples, was performed using tips coupled with anti-insulin monoclonal antibody. An automated liquid handler was programmed to perform aspiration and dispense cycles. Eluate from the purification protocol was submitted for analysis using a TLX-2 multiplex LC system paired with a Thermo Scientific Q Exactive Plus mass spectrometer. Various HPLC column chemistries were evaluated, a column passivation procedure was established, and column heater temperature was optimized to identify a combination of parameters yielding the best chromatographic separation of human insulin and lispro. Additionally, parallel reaction monitoring (PRM) targeted tandem mass spectrometry (MS/MS) analysis was utilized in combination with the full scan data to increase specificity through the monitoring of fragment ions produced from human insulin and each insulin analog. Results We found that a 1000 Å Diphenyl, 2.7 µm, 2.1 x 100 mm analytical column in a column heater maintained at a temperature of 80°C allowed for human insulin and lispro to be differentiated as two chromatographically separated extracted ion chromatographic peaks (XICs) and quantified down to 2.5 mcIU/mL with near-baseline separation. Before use, the column required passivation with a high protein buffer (0.05% bovine serum albumin in 20% acetonitrile [ACN] + 0.2% acetic acid) followed by increasingly organic buffers (20% ACN + 0.2% acetic acid and 50% ACN + 0.2% acetic acid). MS/MS was used to confirm the presence of analogs detected. Conclusions The LC-HRAM-MS method described here, coupled with optimized column chemistry, column passivation, and proper column temperature control allows for chromatographic separation of human insulin and lispro. Incorporating a PRM scan into the mass spectrometry full scan method provides confirmation of the insulin detected in the XICs. The results obtained from preliminary studies suggest this method is appropriate for use to facilitate the clinical investigation of suspected factitious hypoglycemia with the ability to differentiate isomeric compounds, such as human insulin and lispro.
B-151 Development and Validation of Plasma Catecholamines by Mass Spectrometry
Abstract Background Our established method for measuring plasma catecholamines utilized a Shimadzu HPLC coupled to an ESA Coulochem III electrochemical detector. Chromatographic run times were long, resulting in slow turnaround times. Instrument maintenance was labor intensive, and the assay was prone to interferences. To overcome these limitations, we changed the method to liquid chromatography-tandem mass spectrometry (LC-MS/MS) measurements. Methods After the addition of a labeled internal standard for each analyte, samples are loaded onto 50 mg of activated alumina at pH 8.6, utilizing a Tris-HCl, sodium carbonate and EDTA buffer. After incubation the alumina is then washed with 50% acetonitrile followed by water. Elution off the alumina is performed with 2% acetic acid. Derivatization is then performed on the eluate utilizing acetaldehyde and a cyanoborohydride buffer. Following derivatization, the samples are analyzed for epinephrine, norepinephrine, and dopamine by LC-MS/MS using a Sciex 7500 coupled to a ThermoFisher Scientific TLX-4 equipped with Vanquish pumps. Chromatographic separation was obtained using a Phenomenex Kinetex 2.6 um BiPhenyl 50x3 mm analytical column. Results Runtimes were significantly shorter than with the previous method, and no interferences were observed. Assay validation consisted of: intra/inter assay precision, accuracy, recovery, linearity, carryover, limit of detection (LOD), and interferences. Three levels were assessed for intra assay precision and each of the analytes monitored yielded %CVs of less than 6%. Four levels were assessed for inter assay precision and each of the analytes monitored yielded %CVs of less than 10%. When using linear regression analysis to compare results with the previous clinical assay, the slope, y-intercept and R2 were the following; dopamine: 1.06, 2.74, 0.978; epinephrine: 0.905, 2.20, 0.989; norepinephrine: 0.919, 9.75, 0.953. Spike and recovery from five samples yielded a mean average recovery of 93.4% for dopamine, 100% for epinephrine and 98.1% for norepinephrine. For linearity 4 samples were diluted and the mean % difference from expected was -1.66% for dopamine, -0.25% for epinephrine and 1.78% for norepinephrine. Blanks were injected following the high standard and carryover was negligible. LOD was determined by running a low sample pool along with a blank over 20 assays. The LOD was determined to be less than the LLOQ. Sixty-two common drugs/vitamins along with varying levels of hemolysis, lipemia, and bilirubin were also tested to ensure no interferences were seen. Conclusions The LC-MS/MS method exceeded the performance of the historical Shimdazu HPLC system with ESA Coluochem III electrochemical detector method. We anticipate that the better analytical performance will improve the testing quality of our patients.
Application of Liquid Chromatography–Mass Spectrometry Technology for Early Detection of Microalbuminuria in Patients with Kidney Disease