Until recently, the laboratory diagnosis of central nervous system (CNS) infections with herpes simplex virus (HSV) has been limited by poor sensitivity and/or specificity. We assessed the diagnostic utility of PCR for detection of HSV in over 2,100 specimens referred to the Mayo Clinic from August 1993 to May 1996. DNA extracted from cerebrospinal fluid (CSF) samples with IsoQuick was amplified by PCR with oligonucleotide primers directed to the DNA polymerase gene of HSV, yielding a 290-bp amplicon. HSV DNA was detected in 150 (135 by gel electrophoresis, 15 by Southern blotting only) of 2,106 (7.1%) specimens. PCR-positive CNS disease occurred in patients ranging in age from 13 days to 89 years; 59% of the cases occurred in patients between the ages of 30 and 69, and 21 (14%) of the patients were infants. Genotype analysis was not routinely performed; however, amplification of a 335-bp product within the thymidine kinase gene of HSV revealed 13 positions within a span of 80 nucleotides that accurately identified the two serotypes of the virus according to 14 reference strains. We conclude that PCR detection of HSV DNA in CSF specimens should be considered an emerging "gold standard" for the laboratory diagnosis of CNS infections with this virus.
Validation of a Metabolite Panel for a More Accurate Estimation of Glomerular Filtration Rate Using Quantitative LC-MS/MS
AbstractBACKGROUNDClinical practice guidelines recommend estimation of glomerular filtration rate (eGFR) using validated equations based on serum creatinine (eGFRcr), cystatin C (eGFRcys), or both (eGFRcr-cys). However, when compared with the measured GFR (mGFR), only eGFRcr-cys meets recommended performance standards. Our goal was to develop a more accurate eGFR method using a panel of metabolites without creatinine, cystatin C, or demographic variables.METHODSAn ultra-performance liquid chromatography–tandem mass spectrometry assay for acetylthreonine, phenylacetylglutamine, pseudouridine, and tryptophan was developed, and a 20-day, multiinstrument analytical validation was conducted. The assay was tested in 2424 participants with mGFR data from 4 independent research studies. A new GFR equation (eGFRmet) was developed in a random subset (n = 1615) and evaluated in the remaining participants (n = 809). Performance was assessed as the frequency of large errors [estimates that differed from mGFR by at least 30% (1 − P30); goal <10%].RESULTSThe assay had a mean imprecision (≤10% intraassay, ≤6.9% interassay), linearity over the quantitative range (r2 > 0.98), and analyte recovery (98.5%–113%). There was no carryover, no interferences observed, and analyte stability was established. In addition, 1 − P30 in the validation set for eGFRmet (10.0%) was more accurate than eGFRcr (13.1%) and eGFRcys (12.0%) but not eGFRcr-cys (8.7%). Combining metabolites, creatinine, cystatin C, and demographics led to the most accurate equation (7.0%). Neither equation had substantial variation among population subgroups.CONCLUSIONSThe new eGFRmet equation could serve as a confirmatory test for GFR estimation.