Citations

Clear

3 citation(s) found for "Wood, Mark".

Scoring System Prognostic of Outcome in Patients Undergoing Allogeneic Hematopoietic Cell Transplantation for Myelodysplastic Syndrome
Shaffer, Brian C. , Ahn, Kwang Woo , Hu, Zhen‐Huan , Malone, Adriana K. , Valcárcel, David , Hamilton, Betty K. , Kharfan‐Dabaja, Mohamed A. , Saad, Ayman , Warlick, Erica D. , Wirk, Baldeep , Sabloff, Mitchell , Fasan, Omotayo , Gerds, Aaron T. , Marks, David I. , Olsson, Richard F. , Wood, William A. , Costa, Luciano J. , Miller, Alan M. , Cortes, Jörge E. , Daly, Andrew , Kindwall‐Keller, Tamila L. , Kamble, Rammurti T., Rizzieri, David A. , Cahn, Jean‐Yves , William, Basem M. , Litzow, Mark R. , Wiernik, Peter H. , Vij, Ravi , Üstün, Celalettin , Copelan, Edward A. , Kalaycio, Matt, Alyea, Edwin P. , Sobecks, R., Pavletic, Steven Z. , Tallman, Martin S. , Saber, Wael , Nishihori, Taiga , Bacher, Ulrike , Hamilton, Betty, Kharfan-Dabaja, Mohamed A., Cutler, Corey, Warlick, Erica, Wirk, Baldeep Mona, Marks, David, Olsson, Richard, Wood, William Allen, Cortes, Jorge, Kindwall-Keller, Tamila L, Kamble, Rammurti, William, Basem, Savani, Bipin N. , Copelan, Edward, Popat, Uday, Maziarz, Richard, Alyea, Edwin, Sobecks, Ron, Pavletic, Steven, Tallman, Martin, Grunwald, Michael R. , Cutler, Corey S. , Reshef, Ran , Gale, Robert Peter , Liesveld, Jane L. , Popat, Uday R , Maziarz, Richard Thomas , Gerds, Aaron T , Saad, Ayman , Olsson, Richard F , Cortes, Jorge , William, Basem , Costa, Luciano J , Sabloff, Mitchell , Wood, William A , Valcárcel, David

Mayo Clinic

Journal of Clinical Oncology | April 5, 2016 | Volume: 34 | Issue: 16 | Pages: 1864-1871

10.1200/jco.2015.65.0515 | PMID 27044940 Get It

Purpose To develop a system prognostic of outcome in those undergoing allogeneic hematopoietic cell transplantation (allo HCT) for myelodysplastic syndrome (MDS). Patients and Methods We examined 2,133 patients with MDS undergoing HLA-matched (n = 1,728) or -mismatched (n = 405) allo HCT from 2000 to 2012. We used a Cox multivariable model to identify factors prognostic of mortality in a training subset (n = 1,151) of the HLA-matched cohort. A weighted score using these factors was assigned to the remaining patients undergoing HLA-matched allo HCT (validation cohort; n = 577) as well as to patients undergoing HLA-mismatched allo HCT. Results Blood blasts greater than 3% (hazard ratio [HR], 1.41; 95% CI, 1.08 to 1.85), platelets 50 × 109/L or less at transplantation (HR, 1.37; 95% CI, 1.18 to 1.61), Karnofsky performance status less than 90% (HR, 1.25; 95% CI, 1.06 to 1.28), comprehensive cytogenetic risk score of poor or very poor (HR, 1.43; 95% CI, 1.14 to 1.80), and age 30 to 49 years (HR, 1.60; 95% CI, 1.09 to 2.35) were associated with increased hazard of death and assigned 1 point in the scoring system. Monosomal karyotype (HR, 2.01; 95% CI, 1.65 to 2.45) and age 50 years or older (HR, 1.93; 95% CI, 1.36 to 2.83) were assigned 2 points. The 3-year overall survival after transplantation in patients with low (0 to 1 points), intermediate (2 to 3), high (4 to 5) and very high (≥ 6) scores was 71% (95% CI, 58% to 85%), 49% (95% CI, 42% to 56%), 41% (95% CI, 31% to 51%), and 25% (95% CI, 4% to 46%), respectively (P < .001). Increasing score was predictive of increased relapse (P < .001) and treatment-related mortality (P < .001) in the HLA-matched set and relapse (P < .001) in the HLA-mismatched cohort. Conclusion The proposed system is prognostic of outcome in patients undergoing HLA-matched and -mismatched allo HCT for MDS.
Activity enhances dopaminergic long-duration response in Parkinson disease
Kang, Un Jung , Auinger, Peggy , Fahn, Stanley, Oakes, David , Shoulson, Ira , Kieburtz, Karl, Rudolph, Alice, Seibyl, John , Olanow, C. Warren , Tanner, Caroline M., Schifitto, Giovanni , Zhao, Hongwei , Reyes, Lydia, Shinaman, Aileen, Comella, Cynthia L., Blasucci, Lucia M., Samanta, Johan, Stacy, Mark, Williamson, Kelli, Harrigan, Mary, Greene, Paul, Ford, Blair, Moskowitz, Carol, Truong, Daniel , Pathak, Mayank , Jankovic, Joseph, Ondo, William G. , Atassi, Farah, Hunter, Christine , Jacques, Carol, Lannon, Margaret C., Russell, David , Jennings, Danna , Fussell, B., Schwarzschild, Michael A. , Growdon, John H., Tennis, Marsha, Gauthier, Serge , Panisset, Michel , Hall, Jean, Gancher, Stephen T., Hammerstad, John P., Stone, Claudia, Alexander-Brown, Barbara, Molho, Eric , Brown, Diane, Evans, Sharon, Manyam, Bala V., Simpson, Patricia , Wulbrecht, Brian, Whetteckey, Jacqueline, Roberts, Ted E, King, Pamela, Zesiewicz, Theresa A. , Gauger, Lisa, Trugman, Joel M. , Wooten, G. Frederick, Rost‐Ruffner, Elke, Suchowersky, Oksana , Ranawaya, Ranjit, Wood, Susan M. , Pantella, Carol , Kurlan, Roger, Richard, Irene Hegeman, Pearson, N. Shirlene, Caviness, John N., Adler, Charles, Lind, Marlene, Siderowf, Andrew , Colcher, Amy, Lloyd, Mary, Weiner, William J., Shulman, Lisa M. , Koller, William C., Lyons, Kelly , Feldman, Robert G., Ellias, Samuel A., Thomas, Cathi-Ann, Juncos, Jorge L., Watts, Ray L., Partlow, Anna, Tetrud, James W., Togasaki, Daniel M., Stewart, Tracy, Mark, Margery H., Sage, Jacob I., Caputo, Debbie, Gould, Harry J. , Rao, Jayaraman, McKendrick, A. D., Brin, Mitchell F. , Danisi, Fabio , Benabou, Reina, Hubble, Jean, Paulson, George W., Reider, Carson, Birnbaum, Alex, So, Julie , Dubinsky, Richard , Uitti, Ryan J. , Turk, Margaret F., Rottenberg, David A., Hansen, Joy, Ramos, Serrano, Waters, Cheryl , Lew, Mark, Welsh, Mickie, Kawai, Connie, OʼBrien, Christopher , Kumar, Rajeev , Seeberger, Lauren , Judd, Deborah, Mendis, Tilak, Grimes, David A. , Sutherland, Laura, Dawson, Ted M. , Reich, Stephen G. , Frey, Kirk A. , Wernette, K., Marek, Kenneth , Lang, Anthony E. , Goetz, Christopher G. , Jankovic, Joseph, Friedman, Joseph H. , Standaert, David G. , Factor, Stewart Alan , Clark, Jeffrey N. , Martin, W. R. Wayne , Hauser, Robert A. , Perlmutter, Joel S. , Racette, Brad A. , Simuni, Tanya , Saint‐Hilaire, Marie , Miyasaki, Janis M. , Johnston, Lisa , Pahwa, Rajesh , Wszołek, Zbigniew K. , Tuite, Paul , Barclay, Corlane , Dunlop, Rebecca A. , Albin, Roger L.

Mayo Clinic

Neurology | March 30, 2012 | Volume: 78 | Issue: 15 | Pages: 1146-1149

10.1212/wnl.0b013e31824f8056 | PMID 22459675 Get It

Dual-Chamber Versus Single-Chamber Detection Enhancements for Implantable Defibrillator Rhythm Diagnosis
Friedman, Paul A. , McClelland, Robyn L. , Bamlet, William R. , Acosta, Helbert , Kessler, David J. , Munger, Thomas M. , Kavesh, Neal G., Wood, Mark, Daoud, Emile G. , Massumi, Ali, Schuger, Claudio , Shorofsky, Stephen R., Wilkoff, Bruce L. , Glikson, Michael , Wood, Mark, Glikson, Michael , Bamlet, William R

Mayo Clinic

Circulation | June 13, 2006 | Volume: 113 | Issue: 25 | Pages: 2871-2879

10.1161/circulationaha.105.594531 | PMID 16769912 Get It

Background— Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted cardioverter/defibrillator (ICD) therapy. Whether use of optimally programmed dual-chamber ICDs lowers this risk compared with that in single-chamber ICDs is not clear. Methods and Results— Subjects with a clinical indication for ICD (n=400) at 27 participating centers received dual-chamber ICDs and were randomly assigned to strictly defined optimal single- or dual-chamber detection in a single-blind manner. Programming minimized ventricular pacing. The primary end point was the proportion of SVT episodes inappropriately detected from the time of programming until crossover or end of study. On a per-episode basis, 42% of the episodes in the single-chamber arm and 69% of the episodes in the dual-chamber arm were due to SVT. Mortality (3.5% in both groups) and early study withdrawal (14% single-chamber, 11% dual-chamber) were similar in both groups. The rate of inappropriate detection of SVT was 39.5% in the single-chamber detection arm compared with 30.9% in the dual-chamber arm. The odds of inappropriate detection were decreased by almost half with the use of the dual-chamber detection enhancements (odds ratio, 0.53; 95% confidence interval, 0.30 to 0.94; P =0.03). Conclusions— Dual-chamber ICDs, programmed to optimize detection enhancements and to minimize ventricular pacing, significantly decrease inappropriate detection.