Citations

Clear

26 citation(s) found for "Welker, Kirk".

Network- and Measure-Specific Mid-Term Reliability of Multi-Echo Resting-State Functional Magnetic Resonance Imaging on a Compact 3 Tesla Scanner
Kang, Daehun , Welker, Kirk M. , Hermes, Dora, Huston, John , Shu, Yunhong , Kang, Daehun , Hermes, Dora , Bernstein, Matt A.

Mayo Clinic

No container title available | August 13, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.08.07.743542 | PMID 42845319 Get It

Introduction: Understanding mid-term test-retest reliability and within-subject variability is important for interpreting changes observed in longitudinal and intervention studies. The reliability of resting-state functional magnetic resonance imaging (rs-fMRI) is known to vary across measures and brain regions. However, how reliability differs across functional networks and connectivity- and amplitude-based measures, and whether multi-echo acquisition and processing modify these patterns, remain incompletely characterized. Methods: Twenty-two healthy volunteers underwent two rs-fMRI sessions 15.7 ± 4.0 days apart on a Compact 3T scanner. Multi-echo, middle-echo, and independently acquired single-echo datasets were compared, with multi-echo independent component analysis additionally evaluated as a denoising approach. Functional connectivity (FC) and three amplitude-based measures were evaluated using the Schaefer 400 parcellation. Reliability was systematically assessed using intraclass correlation coefficient (ICC), within-subject standard deviation (wSD), and systematic bias at edge or regional, and network levels. Results: Acquisition-dependent differences in reliability were generally modest. Multi-echo acquisition and processing increased functional connectivity strength and the magnitude of amplitude-based measures and improved inferior cortical coverage, but these enhancements did not consistently translate into substantially higher ICC or lower wSD. In contrast, reliability showed clear network-dependent differences. FC reliability varied markedly across network pairs and was not explained by connectivity strength alone; pairs involving the default mode and control networks generally showed more favorable profiles than several somatomotor and visual network pairs. Fractional amplitude of low-frequency fluctuations (fALFF) also showed network-dependent reliability, with the most favorable regional reproducibility observed in the default mode and control networks and lower reproducibility in the somatomotor and visual networks. Conclusion: These findings provide practical mid-term reliability benchmarks for rs-fMRI on a Compact 3T scanner and show that measurement stability varies more clearly across measures and functional networks than across acquisition approaches.
Brain Structural and Functional Alterations in Regions of Pain-processing in Individuals with Rheumatoid Arthritis (P5-2.002)
Chong, Catherine, Musa, Juna , Crowson, C. S., Irani, Anushka, Schwedt, Todd, Welker, Kirk, Davis, John, Schwedt, Todd J. , Davis, John M.

Mayo Clinic

Neurology | June 10, 2026 | Volume: 106 | Issue: 11_Supplement_1 | Pages: No page available

10.1212/wnl.0000000000216313 Get It

Cerebral Oxygen Budgeting: Network-Level BOLD Dynamics During Acute Hypoxia
Kang, Daehun, Haider, Clifton R. , In, Myung-Ho, Gray, Erin M. , Trzasko, Joshua D. , Welker, Kirk M., Senefeld, Jonathon W., Bernstein, Matt A., Holmes, David R., Joyner, M. J., Huston, John, Shu, Yunhong , Kang, Daehun , Kang, Daehun , Uchida, Koji, Curry, Timothy B. , Senefeld, Jonathon W , Uchida, Kôji , Campeau, Norbert G. , In, Myung‐Ho, Welker, Kirk M. , Wiggins, Chad C. , Senefeld, Jonathon W. , Baker, Sarah , Bernstein, Matt A. , Holmes, David R, Joyner, Michael J. , Huston, John

Mayo Clinic

No container title available | March 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.03.27.713294 | PMID 41959491 Get It

Abstract Hypoxia constrains cerebral oxygen availability and challenges brain function and stability. Although hypoxia-responsive functional connectivity (HR-FC) reorganizes rapidly with declining arterial oxygen partial pressure, its relationship to local neurovascular activity remains unclear. We examined time-resolved amplitude of low-frequency fluctuations (ALFF) in blood-oxygenation-level dependent (BOLD) fMRI during graded acute hypoxia in healthy adults, performing a continuous cognitive test (Go/No-go task) with concurrent physiological monitoring. Dynamic ALFF and functional connectivity were estimated using a sliding-window approach and analyzed across large-scale brain networks defined by Schaefer’s 17-network parcellation. Severe hypoxia elicited temporally dissociated responses across modalities. Functional connectivity increased monotonically, whereas ALFF exhibited pronounced nonlinear modulation, including phase-dependent divergence across networks. During hypoxic decompensation, the default mode network (DefaultA) showed marked ALFF suppression, whereas a ventral secondary somatosensory-dominant network (SomMotB) exhibited preferential preservation despite similar engagement in HR-FC. Together, these findings indicate that network-level ALFF captures a distinct yet complementary layer of functional dynamics, with a temporal profile distinct from functional connectivity. Spontaneous BOLD dynamics during acute hypoxia reflect structured network-level modulation rather than a uniform suppression attributable solely to reduced oxygen availability. These findings support a conceptual framework of cerebral oxygen budgeting , in which metabolic constraints reshape functional dynamics across brain networks.
The rarely described association between pseudoaneurysm and aberrant ICA: A case series
Yousif, Paul , Farnsworth, Paul J. , Carlson, Matthew L. , Welker, Kirk M. , Bathla, Girish , Sadaney, Ahmed O El , Lane, Jack I., Farnsworth, Paul , Carlson, Matthew, Welker, Kirk, Guerin, Julie, Bathla, Girish , El Sadaney, Ahmed O , Lane, Jack, Guérin, J.

Mayo Clinic

Interventional Neuroradiology | July 7, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251353316 | PMID 40619847 Get It

Aberrant internal carotid artery (ICA) is a vascular anomaly in which a segment of the ICA courses through the middle ear. The association of aberrant ICAs and pseudoaneurysm formation is not well known and can be an important finding to recognize on imaging. In this series, we present three cases of aberrant ICAs having asymmetric contour deformities consistent with pseudoaneurysms diagnosed utilizing CT of the temporal bone.
Induction of Extremely Severe Nausea via Vestibular Activation on a 7 Tesla MRI Scanner
Fagan, Andrew , Amrami, Kimberly K. , Watson, Robert E. , Anjum, Muhammad, Welker, Kirk M. , Fagan, Andrew J , Anjum, Muhammad A R

Mayo Clinic

Journal of Magnetic Resonance Imaging | November 7, 2024 | Volume: 61 | Issue: 6 | Pages: 2644-2647

10.1002/jmri.29656 | PMID 39506914 Get It

Extremely severe nausea was experienced by four subjects positioned prone on a 7T scanner table with their arm extended overhead for a wrist examination and their head positioned approximately 10–20 cm above the magnet's central axis. Movement through the large static and spatial field gradients of current 7T MRI scanner magnets typically causes mild vestibular activation which is well tolerated by most individuals. However, when positioned off‐axis, the head moves through regions of even larger and more rapidly changing magnetic fields which in the current study were sufficient to induce the extremely severe nausea. Ensuring the head remains on‐axis mitigates this effect.
Functional MR elastography measures visual cortex stiffening proportional to visual contrast intensity in regions of activation
Palnitkar, Harish , Murphy, Matthew C. , Glaser, Kevin J. , Welker, Kirk M. , Huston, John , Arani, Arvin , Palnitkar, Harish R, Campeau, Norbert, Arani, Arvin , Sui, Yi , Manduca, Armando , Campeau, Norbert G. , Ehman, Richard L.

Mayo Clinic

Imaging Neuroscience | April 23, 2024 | Volume: 2 | Issue: No issue available | Pages: No page available

10.1162/imag_a_00172 | PMID 40290564 Get It

Abstract Functional MRI (fMRI) is widely used to spatially localize neural activity in the brain associated with functional stimuli. Functional MR Elastography (fMRE) has recently been introduced as a complementary approach that measures the mechanical response to functional stimulus. The hypothesis of the current study is that the stiffness change in fMRE is proportional to the underlying neural activity. This hypothesis is tested by measuring the median stiffness change in the visual cortex as a function of luminance-matched contrast intensity of a checkerboard visual stimulus in 16 healthy subjects. The fMRE signal in the visual cortex was observed to be proportional to the contrast intensity of the visual stimulus. In regions of activation, fMRE signal increased in the range of 2 ± 1% to 5.8 ± 1% and fMRI signal increased by the expected 0.4 ± 0.2% to 0.9 ± 0.2%, for contrast levels of 5% to 100%, respectively. In conclusion, this study shows that the fMRE signal in the visual cortex can be directly modulated by the contrast intensity of a visual stimulus. The presence of some overlap between fMRI and fMRE regions of activation may suggest two distinct mechanisms governing the fMRI and fMRE signals, which will be investigated in future studies.
The stronger the better - diagnostic utility of 7 Tesla MRI in epilepsy patients (4354)
Chalia, Mayur , Witte, Robert J. , Welker, Kirk M. , Panda, Ananya , Brinkmann, Benjamin H. , Britton, Jeffrey W. , Wong‐Kisiel, Lily C.

Mayo Clinic

Neurology | December 7, 2023 | Volume: 96 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.96.15_supplement.4354 Get It

No Increased Mercury Release from Dental Restorations at 1.5T, 3T, or 7T MRI
Burkett, Brian J. , Rasmussen, Chad M. , Fillmore, W. Jonathan , McDonald, Robert J. , Fagan, Andrew , Erdahl, Sarah A , Eckdahl, Steven J., Welker, Kirk M. , Fagan, Andrew J , Burkett, Brian , McDonald, Jennifer S.

Mayo Clinic

Magnetic Resonance in Medicine | September 27, 2023 | Volume: 91 | Issue: 2 | Pages: 660-669

10.1002/mrm.29872 | PMID 37755142 Get It

AbstractPurposeDental amalgam contains mercury and is commonly used in dental restorations. The impact of MRI on mercury excretion from dental amalgam is not well understood across clinical field strengths, especially 7T. We investigated the effects of MRI exposure on mercury excretion using fresh, lab‐created dental amalgam restorations and in extracted teeth with old, pre‐existing restorations.MethodsDonated, unfilled human teeth (n = 120) were restored with amalgam before being stored in saline, artificial saliva, or a dry box prior to MRI scanning. The teeth were placed in individual tubes of fresh artificial saliva and scanned at 1.5T, 3T, or 7T or left unscanned as controls. Mercury concentrations were measured 24–30 h later. Donated teeth with pre‐existing restorations (n = 40) were stored in artificial saliva, scanned at 7T or left unscanned as controls, and mercury concentration tested.ResultsFor teeth extracted and restored in a laboratory, no significant difference was found (F = 2.42, P = 0.072) between mean mercury concentrations of unscanned teeth (13.72 μg/L) and teeth scanned at 1.5T (10.88 μg/L), 3T (12.65 μg/L), or 7T (8.88 μg/L). For teeth extracted with previously placed restorations, no significant difference (P = 0.288) was found between unscanned controls (4.28 μg/L) and teeth scanned at 7T (6.63 μg/L).ConclusionMRI of dental amalgam does not significantly increase mercury excretion at 1.5T, 3T, or 7T compared to unscanned teeth. This holds true for controlled laboratory restorations as well as for those placed and lived with prior to extraction and scanning, demonstrating no added risk to the clinical patient or research subject.
Detection and Mitigation of Neurovascular Uncoupling in Brain Gliomas
Agarwal, Shruti , Welker, Kirk M. , Black, David F. , Little, Jason T. , Passe, Theodore J. , Pillai, Jay J. , DeLone, David R. , Messina, Steven A. , Pillai, Jay J , Bettegowda, Chetan

Mayo Clinic

Cancers | September 8, 2023 | Volume: 15 | Issue: 18 | Pages: 4473

10.3390/cancers15184473 | PMID 37760443 Get It

Functional magnetic resonance imaging (fMRI) with blood oxygen level-dependent (BOLD) technique is useful for preoperative mapping of brain functional networks in tumor patients, providing reliable in vivo detection of eloquent cortex to help reduce the risk of postsurgical morbidity. BOLD task-based fMRI (tb-fMRI) is the most often used noninvasive method that can reliably map cortical networks, including those associated with sensorimotor, language, and visual functions. BOLD resting-state fMRI (rs-fMRI) is emerging as a promising ancillary tool for visualization of diverse functional networks. Although fMRI is a powerful tool that can be used as an adjunct for brain tumor surgery planning, it has some constraints that should be taken into consideration for proper clinical interpretation. BOLD fMRI interpretation may be limited by neurovascular uncoupling (NVU) induced by brain tumors. Cerebrovascular reactivity (CVR) mapping obtained using breath-hold methods is an effective method for evaluating NVU potential.
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
Kang, Daehun , In, Myung‐Ho , Halverson, Maria, Meyer, Nolan , Ahmed, Zaki , Gray, Erin M. , Fernandez, Brice , Black, David F. , Welker, Kirk M. , Trzasko, Joshua D. , Huston, John , Shu, Yunhong , Huston, John , Halverson, Maria A, Meyer, Nolan K , Ahmed, Zaki , Fernandez, Brice , Shu, Yunhong , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Madhavan, Radhika , Foo, Thomas , Bernstein, Matt A.

Mayo Clinic

Sensors | April 28, 2023 | Volume: 23 | Issue: 9 | Pages: 4329

10.3390/s23094329 | PMID 37177534 Get It

In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.