Abstract Objectives In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience. METHODS All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020–7/2024) were evaluated using a central database with 1 year follow-up. RESULTS A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency. CONCLUSIONS RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.
Seven-year outcomes after surgical aortic valve replacement with a stented bovine pericardial bioprosthesis in over 1100 patients: a prospective multicentre analysis
Abstract OBJECTIVES Safety, efficacy and durability are important considerations when selecting a bioprosthesis for aortic valve replacement (AVR). This study assessed 7-year clinical outcomes and haemodynamic performance of the Avalus bioprosthesis. METHODS Patients indicated for surgical AVR were enrolled in this prospective, nonrandomized trial, conducted across 39 sites globally. The primary end-point of this analysis was freedom from surgical explant or percutaneous valve-in-valve reintervention due to structural valve deterioration (SVD) at 7 years of follow-up, determined using Kaplan–Meier (KM) analysis. We also evaluated a composite end-point of SVD and/or severe haemodynamic dysfunction requiring reintervention. Survival, valve-related safety events and haemodynamic performance were assessed. Deaths and safety events were adjudicated by an independent clinical events committee. RESULTS A total of 1132 patients underwent surgical AVR. Mean age was 70 years; 854 patients (75%) were men. The mean STS risk of mortality was 2.0 ± 1.4%, and 659 patients (58%) had a New York Heart Association classification of I/II. One or more concomitant procedures were performed in 577 patients (51%). At 7 years, the Kaplan–Meier rate of freedom from SVD/severe haemodynamic dysfunction requiring reintervention was 1.2% (0.5–2.5%) with no cases adjudicated as SVD. The survival rate was 82.6% (79.5–85.0%). The KM event rate was 5.7% (4.3–7.7%) for reintervention, 6.3% (4.9–8.3%) for endocarditis and 0.4% (0.1–1.1%) for valve thrombosis. Mean aortic gradient, dimensionless velocity index and effective orifice area were 13.8 ± 5.9 mmHg, 0.42 ± 0.09 and 1.99 ± 0.53 cm2, respectively. CONCLUSIONS This analysis demonstrated excellent durability of the Avalus valve with good clinical outcomes and stable haemodynamic performance through 7 years of follow-up.