Citations

Clear

44 citation(s) found for "Watson, Robert".

Effectiveness of Ferromagnetic Detectors in Identifying Diabetes Management Devices During Pre‐ MRI Screening
Watson, Robert E. , Keene, Mark N., Heimer, Jean, LANGE, CINDY de, Lange, Cindy, Keene, M.N., Heimer, Jean M.

Mayo Clinic

Journal of Magnetic Resonance Imaging | July 7, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/jmri.70426 | PMID 42410213 Get It

Artificial intelligence‐based statistical modeling delineates architectural distortion in focal cortical dysplasia
Cannon, Andrew , Tian, Roland, Ebner, Blake , Burkett, Brian J. , Gompel, Jamie Van, Hartley, Christopher P., Moreira, Roger K. , Raghunathan, Aditya, Gompel, Jamie J. Van , Burkett, Brian , Van Gompel, Jamie J , Wong-Kisiel, Lily C. , Watson, Robert E., Wong‐Kisiel, Lily C. , Hartley, Christopher P.

Mayo Clinic

Brain Pathology | March 26, 2026 | Volume: 36 | Issue: 5 | Pages: No page available

10.1111/bpa.70096 | PMID 42767799 Get It

Abstract In epilepsy patients lacking magnetic resonance imaging‐visible lesions such as focal cortical dysplasia (FCD), surgical resections target regions with abnormal electroencephalographic (EEG) activity. However, histopathological identification of subtle cortical architectural abnormalities in these specimens remains challenging. We investigated whether artificial intelligence (AI)‐based morphometric and spatial analysis of NeuN‐stained cortical sections could detect neuronal architectural disorganization in epilepsy resections, including regions without definitive histologic dysplasia. Whole slide images were generated from 83 FCD regions and 19 neurologically normal autopsy controls. Regions of interest were annotated in QuPath as FCD, FCD‐adjacent, FCD‐distant, apparently normal (abnormal EEG without histologic dysplasia), and true normal (autopsy controls). NeuN‐positive neurons were detected using QuPath (90% sensitivity, 12% false positive rate). Spatial and morphometric features—including neuronal clustering, distribution inhomogeneity, and nuclear morphology—were extracted and used to train a multinomial, Least Absolute Shrinkage and Selection Operator‐regularized regression classifier. The classifier achieved 70.6% accuracy in subregion classification and 88.2% accuracy in overall specimen diagnosis. Notably, regions with abnormal EEG but lacking histologic dysplasia exhibited quantifiable architectural disorganization similar to those seen in areas adjacent to FCD and distinct from control tissue. AI‐driven analysis of neuronal morphology and spatial distribution reveals subtle cortical disorganization in epilepsy resections, including in histologically ambiguous regions. Further investigation is warranted to determine if this methodology can enhance the diagnostic yield of neuropathological evaluation and support more precise surgical targeting in epilepsy.
Plain Film Acquisition Techniques for Identification of Cochlear Implant Magnet Displacement
Lange, C De, Carlson, Matthew L, Epperson, Madison V. , Lange, Cindy L, Carlson, Matthew L , Epperson, Madison V. , Watson, Robert E., Carlson, Matthew L.

Mayo Clinic

The Laryngoscope | March 8, 2026 | Volume: 136 | Issue: 6 | Pages: 2761-2764

10.1002/lary.70449 | PMID 41773539 Get It

Induction of Extremely Severe Nausea via Vestibular Activation on a 7 Tesla MRI Scanner
Fagan, Andrew , Amrami, Kimberly K. , Watson, Robert E. , Anjum, Muhammad, Welker, Kirk M. , Fagan, Andrew J , Anjum, Muhammad A R

Mayo Clinic

Journal of Magnetic Resonance Imaging | November 7, 2024 | Volume: 61 | Issue: 6 | Pages: 2644-2647

10.1002/jmri.29656 | PMID 39506914 Get It

Extremely severe nausea was experienced by four subjects positioned prone on a 7T scanner table with their arm extended overhead for a wrist examination and their head positioned approximately 10–20 cm above the magnet's central axis. Movement through the large static and spatial field gradients of current 7T MRI scanner magnets typically causes mild vestibular activation which is well tolerated by most individuals. However, when positioned off‐axis, the head moves through regions of even larger and more rapidly changing magnetic fields which in the current study were sufficient to induce the extremely severe nausea. Ensuring the head remains on‐axis mitigates this effect.
Editorial Comment: Fetal Ultrasound, 1.5-T MRI, or 3-T MRI—No Differences in Body Size Parameters at Birth
Watson, Robert E.

Mayo Clinic

American Journal of Roentgenology | September 18, 2024 | Volume: 223 | Issue: 5 | Pages: No page available

10.2214/ajr.24.32037 | PMID 39291950 Get It

Contrast Media in Pregnant and Lactating Patients, From the AJR Special Series on Contrast Media
Bookwalter, Candice A., McDonald, Robert J. , Packard, Annie T. , Little, Jason T. , Watson, Robert E. , McDonald, Jennifer S.

Mayo Clinic

American Journal of Roentgenology | July 24, 2024 | Volume: 224 | Issue: 4 | Pages: No page available

10.2214/ajr.24.31415 | PMID 39046138 Get It

An Unusual Presentation of Late-Onset Alexander Disease with Slow Orthostatic Tremor and a Novel GFAP Variant (P6.065)
Stitt, Derek , Gavrilova, Ralitza, Watson, Robert E. , Hassan, Anhar

Mayo Clinic

Neurology | December 7, 2023 | Volume: 90 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.90.15_supplement.p6.065 Get It

Scalp Electroencephalography and Intraoperative Electrocorticography and Temporal Lobe Epilepsy Surgical Outcomes in Patients with Normal MRI (PD4.006)
Hoffman, E. Matthew , Cascino, Gregory D. , So, Elson, Marsh, W. Richard , Watson, Robert E. , Burkholder, David B. , Šulc, Vlastimil , Britton, Jeffrey W. , So, Elson L., Gompel, Jamie J. Van , Worrell, Gregory A.

Mayo Clinic

Neurology | December 7, 2023 | Volume: 80 | Issue: 7_supplement | Pages: No page available

10.1212/wnl.80.7_supplement.pd4.006 Get It

Magnetic Resonance Imaging in Patients with Cochlear Implants without Magnet Removal: A Radiology-Administered Protocol to Enhance Operational Efficiency and Improve Workflow
Johnson, Brian J. , Macielak, Robert J. , Watson, Robert E. , Heimer, Jean M., Wiste, Britany J., Lane, John I. , Edmonson, Heidi A. , Carlson, Matthew L. , Johnson, B Jake

Mayo Clinic

Otology & Neurotology | June 6, 2023 | Volume: 44 | Issue: 7 | Pages: 664-671

10.1097/mao.0000000000003898 | PMID 37278159 Get It

Objective To describe the development, implementation, and validation of a radiology-administered protocol to obtain magnetic resonance imaging (MRI) in patients with cochlear implants and auditory brainstem implants without magnet removal. Study Design Retrospective review and description of novel care pathway. Methods A radiology-administered protocol was designed based on careful input from the radiology safety committee and neurotology. Radiology technologist training modules, consent instructions, patient educational material, clinical audits, and other safeguards were implemented, with samples provided in this report. The primary outcomes measured included instances of magnet displacement during MRI and premature termination of MRI studies secondary to pain. Results Between June 19, 2018, and October 12, 2021, 301 implanted ears underwent MRI without magnet removal, including 153 devices housing diametric MRI-conditional magnets, and 148 implants with conventional axial (i.e., nondiametric) magnets. Among cases with diametric MRI-conditional magnets, all studies were completed without magnet dislodgement or need to terminate imaging early due to pain. Among cases with conventional axial (nondiametric) magnets, 29 (19.6%) MRI studies were stopped prematurely secondary to pain or discomfort; the overall rate of this event was 9.6% (29 of 301) among the entire study cohort. In addition, 6.1% (9 of 148) experienced confirmed magnet displacement despite headwrap placement; the overall rate among all cases was 3.0% (9 of 301). Eight of these patients received successful external magnet reseating through manual pressure on the external scalp without surgery, and one required surgical replacement of the magnet in the operating room. There were no documented instances of hematoma, infection, device or magnet extrusion, internal device movement (i.e., gross receiver-stimulator migration), or device malfunction in this cohort related to MRI. Conclusions We present the successful implementation of a radiology-administered protocol designed to streamline care for cochlear implant and auditory brainstem implant recipients who require MRI and ease clinical demands for otolaryngology providers. Examples of resources developed, including a process map, radiology training modules, consent instructions, patient educational materials, clinical audit, and other procedural safety measures are provided so interested groups may consider adapting and implementing related measures according to need.
Cochlear Implants and Magnetic Resonance Imaging: Experience With Over 100 Studies Performed With Magnets in Place
Fussell, Wanda L., Patel, Neil S. , Carlson, Matthew L. , Neff, Brian A., Watson, Robert E. , Lane, John I. , Driscoll, Colin L. W.

Mayo Clinic

Otology & Neurotology | October 11, 2020 | Volume: 42 | Issue: 1 | Pages: 51-58

10.1097/mao.0000000000002866 | PMID 33044338 Get It

Objective: To evaluate adverse events and feasibility of performing 1.5-T MRI in patients with cochlear implants (CI) and auditory brainstem implants (ABI). Setting: Single tertiary academic referral center. Patients: CI and ABI recipients undergoing 1.5-T MRI without internal magnet removal. Intervention(s): MRI after tight headwrap application. Main Outcome Measures: Adverse events, patient tolerance. Results: A total of 131 MR studies in 79 patients were performed, with a total of 157 study ears. Sixty-one patients (77%) had unilateral devices. Four patients (5%) underwent MRI with ABI magnets in place. Sixteen patients (20%) had MRI-compatible devices that did not require a head wrap. There were no instances of device stimulation, device malfunction, or excessive heating of the receiver-stimulator package. Magnet tilt requiring manual repositioning occurred during seven studies (4.5%) and magnet displacement requiring operative intervention occurred during seven studies (4.5%). Significant pain where imaging had to be discontinued occurred during three episodes (2%). No adverse events were noted among patients who underwent MRI with an MRI-compatible magnet. Conclusions: MRI with CI or ABI magnets in place is associated with a low prevalence of adverse events when performed in a controlled setting. Many partial magnet displacements can be corrected with firm manual pressure. Devices with magnets that align with the field within their housing were not associated with any adverse events and do not require immobilization of the magnet during the scan. These may be valuable in patients with known or anticipated need for MRI.