Citations

Clear

3 citation(s) found for "Wang, Yuping".

Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology
Wiebe, Samuel , Jeppesen, Jesper , Tatum, William O. , Brázdil, Milan , Wang, Yuping , Herman, Susan T. , Ryvlin, Philippe , Beniczky, Sándor , Wiebe, Samuel , Jeppesen, Jesper , Tatum, William O , Brazdil, Milan , Ryvlin, Philippe

Mayo Clinic

Epilepsia | March 5, 2021 | Volume: 62 | Issue: 3 | Pages: 632-646

10.1111/epi.16818 | PMID 33666944 Get It

Abstract The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta‐Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic‐clonic seizures (GTCS) and focal‐to‐bilateral tonic‐clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
3D Printing for Bio-Synthetic Biliary Stents
Boyer, Christen J., Boktor, Moheb , Samant, Hrishikesh , White, Luke A. , Wang, Yuping , Ballard, David H. , Huebert, Robert C. , Woerner, Jennifer E., Ghali, Ghali E., Alexander, J. Steven , Alexander, J Steven , Huebert, Robert , Ballard, David H

Mayo Clinic

Bioengineering | February 12, 2019 | Volume: 6 | Issue: 1 | Pages: 16

10.3390/bioengineering6010016 | PMID 30744131 Get It

Three-dimensional (3D) printing is an additive manufacturing method that holds great potential in a variety of future patient-specific medical technologies. This project validated a novel crosslinked polyvinyl alcohol (XL-PVA) 3D printed stent infused with collagen, human placental mesenchymal stem cells (PMSCs), and cholangiocytes. The biofabrication method in the present study examined 3D printing and collagen injection molding for rapid prototyping of customized living biliary stents with clinical applications in the setting of malignant and benign bile duct obstructions. XL-PVA stents showed hydrophilic swelling and addition of radiocontrast to the stent matrix improved radiographic opacity. Collagen loaded with PMSCs contracted tightly around hydrophilic stents and dense choloangiocyte coatings were verified through histology and fluorescence microscopy. It is anticipated that design elements used in these stents may enable appropriate stent placement, provide protection of the stent-stem cell matrix against bile constituents, and potentially limit biofilm development. Overall, this approach may allow physicians to create personalized bio-integrating stents for use in biliary procedures and lays a foundation for new patient-specific stent fabrication techniques.
High-frequency stimulation of anterior nucleus of thalamus desynchronizes epileptic network in humans
Yu, Tao , Wang, Xueyuan , Li, Yongjie , Zhang, Guojun , Ni, Duanyu , Qiao, Liang , Liu, Chang , Li, Liping, Ren, Liankun , Wang, Yuping , Worrell, Gregory A. , Chauvel, Patrick

Mayo Clinic

Brain | June 16, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/brain/awy187 | PMID 29985998 Get It