Citations

Clear

6 citation(s) found for "Wang, Peilong".

Using large language models to automate summarization of CT simulation orders in radiation oncology
Cao, Meiyun, Hu, S.X. , Sharp, Jason, Clouser, Edward , Lam, Louis, Ding, Xiaoning, Toesca, Diego Santos, Raulston, Brianne C, Lindholm, Wendy S., Patel, Samir H. , Vora, Sujay A., Wang, P. , Clouser, Edward Lee , Lam, Linda L, Wang, Peilong , Liu, Wei , Toesca, Diego A.S. , Hu, Shaw, Sharp, Jason, Holmes, Jason , Liu, Wei

Mayo Clinic

Journal of Applied Clinical Medical Physics | October 28, 2025 | Volume: 26 | Issue: 11 | Pages: No page available

10.1002/acm2.70310 | PMID 41144781 Get It

Abstract Background In the current clinical workflow of radiation oncology, therapists manually summarize the physician‐issued Computed Tomography (CT) simulation orders to prepare patients' CT simulations. This process increases the workload, introduces variability in documentation quality, and is prone to human errors. Purpose This study aims to address these challenges using a large language model (LLM) to automate the generation of summaries from the CT simulation orders and evaluate its performance. Methods A total of 607 CT simulation orders were collected from the Aria database at our institution. A locally hosted LLaMa 3.1 405B model, accessed via the Application Programming Interface (API) service, was used to extract keywords from the CT simulation orders and generate summaries. The downloaded CT simulation orders were categorized into seven groups based on treatment modalities and disease sites. For each group, a customized instruction prompt was developed collaboratively with therapists to guide the LLaMa 3.1 405B model in generating summaries. The ground truth for the corresponding summaries was manually derived by carefully reviewing each CT simulation order and subsequently verified by therapists. The accuracy of the LLM‐generated summaries was evaluated by therapists using the ground truth. Results Over 98% of the LLM‐generated summaries aligned with the ground truth in terms of accuracy. Our evaluations showed an improved consistency in format and enhanced readability from the LLM‐generated summaries compared to the corresponding therapist‐generated summaries. This automated approach demonstrated consistent performance across all groups, regardless of treatment modality or disease site. Conclusions This study demonstrated the high precision and consistency of the LLaMa 3.1 405B model in extracting keywords and summarizing CT simulation orders, suggesting that LLMs have great potential to assist in this task, reduce the workload of CT simulation therapists and improve radiation oncology workflow efficiency.
Large language models for bioinformatics
Ruan, Wei, Lyu, Yanjun , Zhang, Jing , Cai, Jiazhang , Lu, Yao , Wang, Tao , Liu, Yufang , Fang, Luyang , Liu, Ziyu , Liu, Zhengliang , Li, Yiwei , Wu, Zihao , Chen, Junhao , Jiang, Hanqi, Yang, Zhenyuan, Liang, Shizhe, Zhang, Wei , Ma, Terry, Dou, Yuan , Zhang, Jianli , Gong, Xinyu , Gan, Qi , Zou, Yusong , Chen, Z. J. , Qian, Yuanxin, Yu, Shuo , Song, Kenan, Sikora, Andrea, Li, Xiang , Wang, Yingfeng , Zhong, Wenxuan, Liu, Rongjie , Huang, Chao , Shen, Ye , Yan, Yajun , Liu, Tianming, Huang, Chao , Song, Kenan , Wang, Peilong, Chen, Jingyuan, Song, Kenan , Ruan, Wei, Shu, Peng , Yang, Ge , Gao, Shang , Wang, Yue , Wang, Peilong , Zhao, Lin , Jiang, Hanqi , Pan, Yi Feng , Chen, Jingyuan , Dou, Yuan, Chen, Z. J. , Qian, Yuanxin, Jin, Lu , Wang, Xianqiao , Sikora, Andrea , Li, Gang , Li, Quanzheng , Zhang, Lu, Abate, Yohannes , He, Lifang , Zhong, Wenxuan, Liu, Wei , Ma, Ping , Zhu, Hongtu , Zhu, Dajiang

Mayo Clinic

Quantitative Biology | September 29, 2025 | Volume: 14 | Issue: 1 | Pages: No page available

10.1002/qub2.70014 | PMID 41676319 Get It

Abstract With the rapid advancements in large language model technology and the emergence of bioinformatics‐specific language models (BioLMs), there is a growing need for a comprehensive analysis of the current landscape, computational characteristics, and diverse applications. This survey aims to address this need by providing a thorough review of BioLMs, focusing on their evolution, classification, and distinguishing features, alongside a detailed examination of training methodologies, datasets, and evaluation frameworks. We explore the wide‐ranging applications of BioLMs in critical areas such as disease diagnosis, drug discovery, and vaccine development, highlighting their impact and transformative potential in bioinformatics. We identify key challenges and limitations inherent in BioLMs, including data privacy and security concerns, interpretability issues, biases in training data and model outputs, and domain adaptation complexities. Finally, we highlight emerging trends and future directions, offering valuable insights to guide researchers and clinicians toward advancing BioLMs for increasingly sophisticated biological and clinical applications.
Fine‐tuning open‐source large language models to improve their performance on radiation oncology tasks: A feasibility study to investigate their potential clinical applications in radiation oncology
Wang, P. , Liu, Zhengliang , Li, Yiwei , Shu, Peng , Li, Xiang , Laughlin, Brady, Toesca, Diego Santos, Vargas, Carlos , Vora, Sujay A., Patel, Samir H. , Liu, Tianming , Wang, Peilong, Laughlin, Brady S. , Toesca, Diego A.S. , Wang, Peilong, Holmes, Jason , Shu, Peng, Zhang, Lian , Li, Quanzheng , Sio, Terence T. , Liu, Wei , Li, Xiang

Mayo Clinic

Medical Physics | July 16, 2025 | Volume: 52 | Issue: 7 | Pages: No page available

10.1002/mp.17985 | PMID 40665561 Get It

Abstract Background The radiation oncology clinical practice involves many steps relying on the dynamic interplay of abundant text data. Large language models have displayed remarkable capabilities in processing complex text information. But their direct applications in specific fields like radiation oncology remain underexplored. Purpose This study aims to investigate whether fine‐tuning LLMs with domain knowledge can improve the performance on Task (1) treatment regimen generation, Task (2) treatment modality selection (photon, proton, electron, or brachytherapy), and Task (3) ICD‐10 code prediction in radiation oncology. Methods Data for 15 724 patient cases were extracted. Cases where patients had a single diagnostic record, and a clearly identifiable primary treatment plan were selected for preprocessing and manual annotation to have 7903 cases of the patient diagnosis, treatment plan, treatment modality, and ICD‐10 code. Each case was used to construct a pair consisting of patient diagnostics details and an answer (treatment regimen, treatment modality, or ICD‐10 code, respectively) for the supervised fine‐tuning of these three tasks. Open source LLaMA2‐7B and Mistral‐7B models were utilized for the fine‐tuning with the Low‐Rank Approximations method. Accuracy and ROUGE‐1 score were reported for the fine‐tuned models and original models. Clinical evaluation was performed on Task (1) by radiation oncologists, while precision, recall, and F‐1 score were evaluated for Task (2) and (3). One‐sided Wilcoxon signed‐rank tests were used to statistically analyze the results. Results Fine‐tuned LLMs outperformed original LLMs across all tasks with p value ≤ 0.001. Clinical evaluation demonstrated that over 60% of the fine‐tuned LLMs‐generated treatment regimens were clinically acceptable. Precision, recall, and F1‐score showed improved performance of fine‐tuned LLMs. Conclusion Fine‐tuned LLMs demonstrated statistically significant improvements over original LLMs upon three clinically important tasks in radiation oncology. This study explored the feasibility of applying fine‐tuned LLMs in radiation oncology, inspiring further development of utilizing LLMs to assist with radiation oncology tasks.
RadOnc-GPT (gpt-4o) versus human data extraction for prostate cancer clinical research.
Osorio, Mariana Borras, Wang, P. , Liu, Wei , Waddle, Mark R. , Namazi, Mohammad Javad , Holmes, Jason , Routman, David M. , Ebner, Daniel K. , Wang, Peilong

Mayo Clinic

Journal of Clinical Oncology | February 18, 2025 | Volume: 43 | Issue: 5_suppl | Pages: 425-425

10.1200/jco.2025.43.5_suppl.425 Get It

425 Background: Prostate cancer (PC) ranks among the most prevalent cancers in men, with incidence rising due to factors like aging populations and enhanced screening techniques. Effective data extraction from clinical records is crucial for advancing research and improving patient care; however, traditional manual methods can be time-consuming and susceptible to mistakes. This study seeks to evaluate RadOnc-GPT against human annotation for extracting essential clinical information from prostate cancer clinical records. Methods: RadOnc-GPT is a retrieval augmented generation (RAG)-based chatbot with access to a variety of patient data including treatment details, radiology reports, and clinical notes. RadOnc-GPT uses Open AI’s gpt-4o model. Patients who received curative intent radiotherapy as initial treatment for PC in our institution between 2014 and 2023 were randomly selected for evaluation. Relevant Clinical factors were extracted by a human expert annotator on our on-site RedCap database. The extraction of the same variables was performed using RadOnc-GPT. A comparison between the ground truth (human annotation) and RadOnc-GPT, to evaluate the performance of the AI system, was carried out including accuracy, recall and F1 score. Results: A total of 382 PC patients were included in the cohort for data extraction. The clinical variables extracted were the treatment intent, NCCN risk category, T and N stage, Gleason score, radiation volume, and Androgen Deprivation therapy (ADT) use. The overall performance of RadOnc-GPT was excellent, with the highest accuracy achieved for treatment intent (99.7%), Gleason score (98.4%), and Treatment Volume (90.1-99.5%). Conclusions: RadOnc-GPT performed excellent at extracting relevant clinical details from the electronic medical record and radiation oncology information systems with dramatic reduction in time and cost compared with manual review. LLMs could be highly useful for large-scale data extraction in PC research, offering a promising solution for automating the accurate data extraction process. Correct (n) Total (n) Accuracy Recall F1 score RT with curative intent 381 382 99.7 99.9 99.9 Prostate Cancer Risk Category 345 382 90.3 90.4 95.1 Primary tumor staging (T) at diagnosis 368 382 96.3 96.3 97.9 Regional nodal status (N) at diagnosis 352 382 92.1 92.2 95.9 Gleason Score Primary Secondary Total 376372376 382382382 98.497.498.4 98.597.498.5 99.298.799.2 Treated Areas Prostate Pelvic Nodes Para-Aortic Nodes Distant Site 380344378372 382382382382 99.590.19997.4 99.490.199.197.4 99.79599.598.7 ADT Use with RT 365 382 95.5 95.7 97.8
Large Language Models on Radiation Oncology Tasks: Small Fine-Tuned Models vs. Large Vanilla Model
Wang, P. , Liu, Tianming , Wang, Peilong , Liu, Zhengliang , Holmes, Jason , Liu, Wei

Mayo Clinic

No container title available | January 28, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.36227/techrxiv.173808198.86649534/v1 Get It

Purpose: This study compares the performance of small, fine-tuned LLMs with the large original models on two radiation oncology clinical tasks: treatment modality selection and ICD-10 code prediction. Methods: We used data of 403 treatment modality selection cases and 377 ICD-10 code prediction cases. The models used were fine-tuned LLaMA 2 7B and Mistral 7B, as well as the larger LLaMA 3.1 70B and 405B models for comparison. We evaluated the accuracy of all models on these two tasks. Results: Both fine-tuned LLaMA 2 7B and Mistral 7B outperformed LLaMA 3.1 70B and 405B in treatment modality selection task. The fine-tuned LLaMA 2 7B and Mistral 7B models achieved accuracy comparable to the larger models in ICD-10 code prediction. Conclusions: Small models, fine-tuned with radiation oncology data, can achieve performance comparable to-or even surpass-that of larger models.
Time structures of proton pencil beam scanning delivery on a microsecond scale measured with a pixelated semiconductor detector Timepix3
Ding, Xuanfeng , Liang, Xiaoying , Oancea, Cristina , Wang, Peilong, Rule, William G., Liu, Wei , Shen, Jiajian , Liang, Xiaoying , Liu, Wei , Shen, Jiajian , Charyyev, Serdar , Wang, Peilong, Bues, Martin , Lin, Liyong

Mayo Clinic

Journal of Applied Clinical Medical Physics | August 13, 2024 | Volume: 25 | Issue: 9 | Pages: No page available

10.1002/acm2.14486 | PMID 39137008 Get It

AbstractPurposeThe time structures of proton spot delivery in proton pencil beam scanning (PBS) radiation therapy are essential in many clinical applications. This study aims to characterize the time structures of proton PBS delivered by both synchrotron and synchrocyclotron accelerators using a non‐invasive technique based on scattered particle tracking.MethodsA pixelated semiconductor detector, AdvaPIX‐Timepix3, with a temporal resolution of 1.56 ns, was employed to measure time of arrival of secondary particles generated by a proton beam. The detector was placed laterally to the high‐flux area of the beam in order to allow for single particle detection and not interfere with the treatment. The detector recorded counts of radiation events, their deposited energy and the timestamp associated with the single events. Individual recorded events and their temporal characteristics were used to analyze beam time structures, including energy layer switch time, magnet switch time, spot switch time, and the scanning speeds in the x and y directions. All the measurements were repeated 30 times on three dates, reducing statistical uncertainty.ResultsThe uncertainty of the measured energy layer switch times, magnet switch time, and the spot switch time were all within 1% of average values. The scanning speeds uncertainties were within 1.5% and are more precise than previously reported results. The measurements also revealed continuous sub‐milliseconds proton spills at a low dose rate for the synchrotron accelerator and radiofrequency pulses at 7 µs and 1 ms repetition time for the synchrocyclotron accelerator.ConclusionThe AdvaPIX‐Timepix3 detector can be used to directly measure and monitor time structures on microseconds scale of the PBS proton beam delivery. This method yielded results with high precision and is completely independent of the machine log files.