Citations

Clear

2 citation(s) found for "Wang, Haifeng".

A 4‐minute solution for submillimeter whole‐brain T1ρ quantification
Zhu, Yanjie , Ying, Leslie , Qiu, Zhilang , Liu, Qiegen , Jia, Sen , Wang, Haifeng , Peng, Xi , Liu, Xin , Zheng, Hairong , Ying, Leslie , Wang, Haifeng , Peng, Xi , Liang, Dong , Liu, Yuanyuan

Mayo Clinic

Magnetic Resonance in Medicine | January 15, 2021 | Volume: 85 | Issue: 6 | Pages: 3299-3307

10.1002/mrm.28656 | PMID 33421224 Get It

PurposeTo develop a robust, accurate, and accelerated T1ρ quantification solution for submillimeter in vivo whole‐brain imaging.MethodsA multislice T1ρ mapping solution (MS‐T1ρ) was developed based on a two‐acquisition scheme using turbo spin echo with RF cycling to allow for whole‐brain coverage with 0.8‐mm in‐plane resolution. A compressed sensing–based fast imaging method, SCOPE, was used to accelerate the MS‐T1ρ acquisition time to a total scan time of 3 minutes 31 seconds. A phantom experiment was conducted to assess the accuracy of MS‐T1ρ by comparing the T1ρ value obtained using MS‐T1ρ with the reference value obtained using the standard single‐slice T1ρ mapping method. In vivo scans of 13 volunteers were acquired prospectively to validate the robustness of MS‐T1ρ.ResultsIn the phantom study, the T1ρ values obtained with MS‐T1ρ were in good agreement with the reference T1ρ values (R2 = 0.9991) and showed high consistency throughout all slices (coefficient of variation = 2.2 ± 2.43%). In the in vivo experiments, T1ρ maps were successfully acquired for all volunteers with no visually noticeable artifacts. There was no significant difference in T1ρ values between MS‐T1ρ acquisitions and fully sampled acquisitions for all brain tissues (p‐value > .05). In the intraclass correlation coefficient and Bland‐Altman analyses, the accelerated T1ρ measurements show moderate to good agreement to the fully sampled reference values.ConclusionThe proposed MS‐T1ρ solution allows for high‐resolution whole‐brain T1ρ mapping within 4 minutes and may provide a potential tool for investigating neural diseases.
In vivo quantitation of rare circulating tumor cells by multiphoton intravital flow cytometry
He, Wei , Hartmann, Lynn C. , Low, Philip S. , Wang, Haifeng , Cheng, Ji‐Xin

Mayo Clinic

Proceedings of the National Academy of Sciences | June 29, 2007 | Volume: 104 | Issue: 28 | Pages: 11760-11765

10.1073/pnas.0703875104 | PMID 17601776 Get It

Quantitation of circulating tumor cells (CTCs) constitutes an emerging tool for the diagnosis and staging of cancer, assessment of response to therapy, and evaluation of residual disease after surgery. Unfortunately, no existing technology has the sensitivity to measure the low numbers of tumor cells (<1 CTC per ml of whole blood) that characterize minimal levels of disease. We present a method, intravital flow cytometry, that noninvasively counts rare CTCs in vivo as they flow through the peripheral vasculature. The method involves i.v. injection of a tumor-specific fluorescent ligand followed by multiphoton fluorescence imaging of superficial blood vessels to quantitate the flowing CTCs. Studies in mice with metastatic tumors demonstrate that CTCs can be quantitated weeks before metastatic disease is detected by other means. Analysis of whole blood samples from cancer patients further establishes that human CTCs can be selectively labeled and quantitated when present at ≈2 CTCs per ml, opening opportunities for earlier assessment of metastatic disease.