Citations

Clear

3 citation(s) found for "Tollefsrud, Katrina".

Biventricular Pressure–Volume Loop Assessment of Impella 5.5 in an Acute ST‐Segment–Elevation Myocardial Infarction Shock Model Unmasks Diminished Right Ventricular Reserve
Inglis, Sara S , Rahme, Serena, Rizzo, Skylar A , Witt, Tyra, Nagel, Mary , Sarrafian, Tiffany, Tollefsrud, Katrina , Mahlberg, Ryan C , Stalboerger, Paul, Rosenbaum, Andrew N , Behfar, Atta

Mayo Clinic

Journal of the American Heart Association | September 25, 2026 | Volume: 15 | Issue: 19 | Pages: No page available

10.1161/jaha.125.047609 | PMID 42786601 Get It

Background The Impella 5.5 is employed to provide left ventricular support in cardiogenic shock. Mechanistic understanding of biventricular relationships is essential in device optimization. Using a porcine model of acute myocardial infarction in tandem with pressure–volume loops, this study aimed to understand the impact of Impella 5.5 on biventricular hemodynamics. Methods Using Domestic Yorkshire pigs, an Impella 5.5 was inserted percutaneously under fluoroscopic guidance via carotid/aortic access and an acute myocardial infarction was created. Biventricular pressure–volume loops and derived parameters were generated for each level of support before (n=6) and after myocardial infarction (n=6). Results With increasing Impella 5.5 support, left ventricular pressure–volume loops shifted left, and right ventricular (RV) loops shifted right. In a healthy porcine heart, the RV adequately compensated for increased preload from the device, demonstrated by increased RV performance at higher P levels. After myocardial infarction, pigs were unable to tolerate speeds beyond P7 from diminished RV stroke volume reserve compared to healthy hearts. Median RV stroke volume percentage change from P1 to P9 before myocardial infarction was from 5.7% (interquartile range, −15.1% to 9.7%) to 50.6% (interquartile range, −11.6% to 60.2; P <0.05), and following acute myocardial infarction from P1 to P7 was from 3.9% (interquartile range, −2.7 to 78.4) to 13.4% (interquartile range, −8.9% to 147.2; P =0.94). Conclusions Impella 5.5 speed modulation highlights significant interventricular interactions with opposing biventricular trends. While the heart can mount an improvement in RV stroke volume with increasing Impella 5.5 support, these data suggest an attenuated response following acute myocardial infarction, which may relate to inadequate response to increased preload needed by the device after infarction affecting the interventricular septum.
Abstract 4363387: Porcine Model of Biventricular Pressure-Volume Loop Assessment during Impella 5.5 Support
Rahme, Serena, Witt, Tyra A. , Nagel, Mary, Tiffany, Sarrafian, Tollefsrud, Katrina, Yalamuri, Suraj , Rosenbaum, Andrew , Inglis, Sara S. , Nagel, Mary, Tiffany, Sarrafian, Behfar, Atta

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4363387 Get It

Introduction: The Impella 5.5 is frequently employed to provide temporary mechanical circulatory support as bridge to recovery or durable therapy. Optimization of device management relies on understanding ventricular pressure-volume (PV) relationships. Aim: The aim of this study was to evaluate the biventricular (BiV) relationship with PV loop assessment during Impella 5.5 support in non-myopathic ventricles. Methods: Six domestic Yorkshire Pigs were used for this study. The Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under ultrasound and fluoroscopic guidance through either the carotid artery or aortic arch, using a 26Fr DrySeal Sheath (Gore, AZ). BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The LV PV loop catheter is positioned via transeptal puncture and with intracardiac echocardiogram guidance. BiV PV loops are generated for each level of Impella 5.5 support. Results: With increasing levels of Impella 5.5 support, left ventricular (LV) PV loops shifted increasingly to the left and right ventricular (RV) loops to the right. Accordingly, LV end-diastolic volume (EDV) decreased (110±4 ml to 90±8 ml; p<0.001) and RV EDV increased (121±7 ml to 147±13 ml; p<0.001), from baseline to P9. Native LV systolic function decreased with increasing Impella 5.5 support, as demonstrated by a reduction in stroke volume (SV) (56±5 ml to 49±5 ml; p<0.001), cardiac output (CO) (3.4±0.8 ml/min to 2.0±0.3 ml/min; p<0.001), ejection fraction (EF) (51±4% to 44±6%; p<0.001), stroke work (SW) (4483±1023 ml*mmHg to 2383±719 ml*mmHg; p<0.001), and LV peak positive dP/dt (825 ± 184 mmHg/s to 523 ± 99 mmHg/s; p<0.001). Conversely, the native RV experienced preload-mediated increase in SV (65±7 ml to 86±20 ml; p<0.001), CO (3.7±0.8 ml/min to 4.3±0.9 ml/min; p<0.001), EF (53±4% to 58±11%; p<0.001), SW (918±143 ml*mmHg to 1529±365 ml*mmHg; p<0.001), and RV dP/dt (164±16 mmHg/s to 228±29 mmHg/s, p<0.001). Load independent contractility was assessed in the LV (1.64±0.33 mmHg/ml to 1.71±0.41 mmHg/ml; p=0.2) and RV (0.25±0.04 mmHg/ml to 0.29±0.05 mmHg/ml; p<0.001). Conclusions: This study highlights ventricular interdependence with Impella 5.5 support with opposing BiV trends. In a healthy heart, the RV can adequately compensate for increased preload offered by the device.
Abstract 4364029: Biventricular Pressure-Volume Loop Assessment of Impella 5.5 in a Porcine Model of Myocardial Infarction
Inglis, Sara, Rahme, Serena, Witt, Tyra A. , Nagel, Mary, Tiffany, Sarrafian, Tollefsrud, Katrina, Yalamuri, Suraj , Rosenbaum, Andrew , Behfar, Atta, Tiffany, Sarrafian, Behfar, Atta

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4364029 Get It

Introduction: Microaxial flow pumps reduce mortality in myocardial infarction (MI) related cardiogenic shock (CS). The Impella 5.5 generates increased flow to provide circulatory support, and optimization relies on mechanistic understanding of pressure-volume (PV) relationships. Aim: Using a porcine model of acute MI in tandem with biventricular (BiV) PV loop conductance catheters, this study aimed to understand the impact of Impella 5.5 on BiV hemodynamics in MI CS. Methods: In 6 Domestic Yorkshire Pigs, an Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under fluoroscopic guidance via carotid or aortic access. An angioplasty balloon catheter was advanced past the first diagonal and inflated to above nominal pressure with blood flow obstruction for 90 minutes. BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The left ventricle (LV) PV loop catheter is positioned via transeptal puncture using intracardiac echocardiography. BiV PV loops are generated for each level of Impella support from P1 to P7. Results: With increasing Impella 5.5 support, LV PV loops shifted to the left and right ventricular (RV) loops to the right. Without statistical significance, LV end diastolic volume (EDV) decreased by a mean of 12.3 ± 10.7% from baseline and RV EDV increased by 32 ± 40%. Native LV function decreased with increasing Impella 5.5 support, demonstrated by a reduction in stroke volume (SV) (35±13 ml to 27±14 ml; p<0.001), cardiac output (CO) derived from SV&heart rate (2.0±0.5 ml/min to 1.7±0.7 ml/min; p<0.001), and ejection fraction (EF) (37±7% to 29±12%; p<0.001). Less consistent trends were noted in peak positive dP/dt and end-systolic pressure volume relationship. Native RV function increased with higher levels of Impella 5.5 support, noted by increasing SV (27±24 ml to 41±28 ml; p=0.004), CO (1.6±1.2 ml/min to 2.3±1.4 ml/min; p=0.001), and EF (42±16% to 45±9%; p=0.04). Arterial elastance and ventriculo-arterial coupling increased in the LV from baseline to P7 (2.2±1.4 mmHg/ml to 2.8±1.0 mmHg/ml and 1.8±0.5 to 3.2±1.9, respectively; p<0.001) and decreased in the RV (1.3±0.7 mmHg/ml to 0.9±0.7 mmHg/ml (p<0.001) and 2.1±2.2 to 1.3±0.6 (p=0.004)). Conclusions: Impella 5.5 speed modulation highlights significant ventricular interdependence in the setting of acute MI. PV loop derived parameters here visualized parameters that may be utilized to improve optimization of hemodynamic support in CS.