Citations

Clear

8 citation(s) found for "Tiffany, Sarrafian".

Biventricular Pressure–Volume Loop Assessment of Impella 5.5 in an Acute ST‐Segment–Elevation Myocardial Infarction Shock Model Unmasks Diminished Right Ventricular Reserve
Inglis, Sara S , Rahme, Serena, Rizzo, Skylar A , Witt, Tyra, Nagel, Mary , Sarrafian, Tiffany, Tollefsrud, Katrina , Mahlberg, Ryan C , Stalboerger, Paul, Rosenbaum, Andrew N , Behfar, Atta

Mayo Clinic

Journal of the American Heart Association | September 25, 2026 | Volume: 15 | Issue: 19 | Pages: No page available

10.1161/jaha.125.047609 | PMID 42786601 Get It

Background The Impella 5.5 is employed to provide left ventricular support in cardiogenic shock. Mechanistic understanding of biventricular relationships is essential in device optimization. Using a porcine model of acute myocardial infarction in tandem with pressure–volume loops, this study aimed to understand the impact of Impella 5.5 on biventricular hemodynamics. Methods Using Domestic Yorkshire pigs, an Impella 5.5 was inserted percutaneously under fluoroscopic guidance via carotid/aortic access and an acute myocardial infarction was created. Biventricular pressure–volume loops and derived parameters were generated for each level of support before (n=6) and after myocardial infarction (n=6). Results With increasing Impella 5.5 support, left ventricular pressure–volume loops shifted left, and right ventricular (RV) loops shifted right. In a healthy porcine heart, the RV adequately compensated for increased preload from the device, demonstrated by increased RV performance at higher P levels. After myocardial infarction, pigs were unable to tolerate speeds beyond P7 from diminished RV stroke volume reserve compared to healthy hearts. Median RV stroke volume percentage change from P1 to P9 before myocardial infarction was from 5.7% (interquartile range, −15.1% to 9.7%) to 50.6% (interquartile range, −11.6% to 60.2; P <0.05), and following acute myocardial infarction from P1 to P7 was from 3.9% (interquartile range, −2.7 to 78.4) to 13.4% (interquartile range, −8.9% to 147.2; P =0.94). Conclusions Impella 5.5 speed modulation highlights significant interventricular interactions with opposing biventricular trends. While the heart can mount an improvement in RV stroke volume with increasing Impella 5.5 support, these data suggest an attenuated response following acute myocardial infarction, which may relate to inadequate response to increased preload needed by the device after infarction affecting the interventricular septum.
Development of a Large Animal Rectovaginal Fistula Model
Westenberg, Danielle N., Sarrafian, Tiffany L. , Mahlberg, Ryan, Stalboerger, Paul G., Trabuco, Emanuel C. , Dozois, Eric J. , Occhino, John A. , Westenberg, Danielle, Mahlberg, Ryan , Behfar, Atta

Mayo Clinic

Urogynecology | May 18, 2026 | Volume: 32 | Issue: 6 | Pages: 646-651

10.1097/spv.0000000000001706 | PMID 42149670 Get It

Importance Rectovaginal fistulas (RVFs) are challenging to treat, often requiring multiple surgical interventions. Research into novel therapies is limited by the lack of a sizeable and representative animal model. Given the similarities in porcine and human vaginal and rectal tissue, pigs are an ideal species for translation to human patients. Objective The objective of this study was to develop a feasible and reproducible RVF model in pigs. Study Design Six female pigs underwent RVF creation and were divided into 3 groups according to the following methods: (1) placement of 1-inch disc magnets across the rectovaginal septum, (2) a 1-inch round defect created using electrocautery and placement of a 1-inch stainless-steel gauge stent, (3) a 1-inch round defect using electrocautery without subsequent stenting. Fistulas were evaluated at 6 weeks with measurements and photographic documentation. The animals were euthanized between 12 and 14 weeks. The primary outcome of this study was fistula patency. Secondary outcomes were fistula dimension and histologic appearance of the fistula tract. Results All pigs did well with no infection or complications related to fistula creation. Both surgical methods reliably resulted in a patent fistula at 14 weeks: cautery alone and cautery with gauge stenting. Only 1 patent fistula in the magnet group was noted at the time of euthanasia. All patent fistulas showed histologic evidence of complete epithelialization of the fistula tract. Conclusions This study demonstrates 3 safe and feasible methods for RVF creation in pigs, with 2 methods showing increased reliability.
Abstract 4363387: Porcine Model of Biventricular Pressure-Volume Loop Assessment during Impella 5.5 Support
Rahme, Serena, Witt, Tyra A. , Nagel, Mary, Tiffany, Sarrafian, Tollefsrud, Katrina, Yalamuri, Suraj , Rosenbaum, Andrew , Inglis, Sara S. , Nagel, Mary, Tiffany, Sarrafian, Behfar, Atta

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4363387 Get It

Introduction: The Impella 5.5 is frequently employed to provide temporary mechanical circulatory support as bridge to recovery or durable therapy. Optimization of device management relies on understanding ventricular pressure-volume (PV) relationships. Aim: The aim of this study was to evaluate the biventricular (BiV) relationship with PV loop assessment during Impella 5.5 support in non-myopathic ventricles. Methods: Six domestic Yorkshire Pigs were used for this study. The Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under ultrasound and fluoroscopic guidance through either the carotid artery or aortic arch, using a 26Fr DrySeal Sheath (Gore, AZ). BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The LV PV loop catheter is positioned via transeptal puncture and with intracardiac echocardiogram guidance. BiV PV loops are generated for each level of Impella 5.5 support. Results: With increasing levels of Impella 5.5 support, left ventricular (LV) PV loops shifted increasingly to the left and right ventricular (RV) loops to the right. Accordingly, LV end-diastolic volume (EDV) decreased (110±4 ml to 90±8 ml; p<0.001) and RV EDV increased (121±7 ml to 147±13 ml; p<0.001), from baseline to P9. Native LV systolic function decreased with increasing Impella 5.5 support, as demonstrated by a reduction in stroke volume (SV) (56±5 ml to 49±5 ml; p<0.001), cardiac output (CO) (3.4±0.8 ml/min to 2.0±0.3 ml/min; p<0.001), ejection fraction (EF) (51±4% to 44±6%; p<0.001), stroke work (SW) (4483±1023 ml*mmHg to 2383±719 ml*mmHg; p<0.001), and LV peak positive dP/dt (825 ± 184 mmHg/s to 523 ± 99 mmHg/s; p<0.001). Conversely, the native RV experienced preload-mediated increase in SV (65±7 ml to 86±20 ml; p<0.001), CO (3.7±0.8 ml/min to 4.3±0.9 ml/min; p<0.001), EF (53±4% to 58±11%; p<0.001), SW (918±143 ml*mmHg to 1529±365 ml*mmHg; p<0.001), and RV dP/dt (164±16 mmHg/s to 228±29 mmHg/s, p<0.001). Load independent contractility was assessed in the LV (1.64±0.33 mmHg/ml to 1.71±0.41 mmHg/ml; p=0.2) and RV (0.25±0.04 mmHg/ml to 0.29±0.05 mmHg/ml; p<0.001). Conclusions: This study highlights ventricular interdependence with Impella 5.5 support with opposing BiV trends. In a healthy heart, the RV can adequately compensate for increased preload offered by the device.
Abstract 4364029: Biventricular Pressure-Volume Loop Assessment of Impella 5.5 in a Porcine Model of Myocardial Infarction
Inglis, Sara, Rahme, Serena, Witt, Tyra A. , Nagel, Mary, Tiffany, Sarrafian, Tollefsrud, Katrina, Yalamuri, Suraj , Rosenbaum, Andrew , Behfar, Atta, Tiffany, Sarrafian, Behfar, Atta

Mayo Clinic

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4364029 Get It

Introduction: Microaxial flow pumps reduce mortality in myocardial infarction (MI) related cardiogenic shock (CS). The Impella 5.5 generates increased flow to provide circulatory support, and optimization relies on mechanistic understanding of pressure-volume (PV) relationships. Aim: Using a porcine model of acute MI in tandem with biventricular (BiV) PV loop conductance catheters, this study aimed to understand the impact of Impella 5.5 on BiV hemodynamics in MI CS. Methods: In 6 Domestic Yorkshire Pigs, an Impella 5.5 (J&J MedTech, NJ) was inserted percutaneously under fluoroscopic guidance via carotid or aortic access. An angioplasty balloon catheter was advanced past the first diagonal and inflated to above nominal pressure with blood flow obstruction for 90 minutes. BiV PV loop conductance catheters (Sigma-M, CD Leycom, Hengelo, The Netherlands) were inserted via femoral venous access. The left ventricle (LV) PV loop catheter is positioned via transeptal puncture using intracardiac echocardiography. BiV PV loops are generated for each level of Impella support from P1 to P7. Results: With increasing Impella 5.5 support, LV PV loops shifted to the left and right ventricular (RV) loops to the right. Without statistical significance, LV end diastolic volume (EDV) decreased by a mean of 12.3 ± 10.7% from baseline and RV EDV increased by 32 ± 40%. Native LV function decreased with increasing Impella 5.5 support, demonstrated by a reduction in stroke volume (SV) (35±13 ml to 27±14 ml; p<0.001), cardiac output (CO) derived from SV&heart rate (2.0±0.5 ml/min to 1.7±0.7 ml/min; p<0.001), and ejection fraction (EF) (37±7% to 29±12%; p<0.001). Less consistent trends were noted in peak positive dP/dt and end-systolic pressure volume relationship. Native RV function increased with higher levels of Impella 5.5 support, noted by increasing SV (27±24 ml to 41±28 ml; p=0.004), CO (1.6±1.2 ml/min to 2.3±1.4 ml/min; p=0.001), and EF (42±16% to 45±9%; p=0.04). Arterial elastance and ventriculo-arterial coupling increased in the LV from baseline to P7 (2.2±1.4 mmHg/ml to 2.8±1.0 mmHg/ml and 1.8±0.5 to 3.2±1.9, respectively; p<0.001) and decreased in the RV (1.3±0.7 mmHg/ml to 0.9±0.7 mmHg/ml (p<0.001) and 2.1±2.2 to 1.3±0.6 (p=0.004)). Conclusions: Impella 5.5 speed modulation highlights significant ventricular interdependence in the setting of acute MI. PV loop derived parameters here visualized parameters that may be utilized to improve optimization of hemodynamic support in CS.
A bioadhesive pacing lead for atraumatic cardiac monitoring and stimulation in rodent and porcine models
Deng, Jue , Wu, Jingjing , Sarrafian, Tiffany L. , Varela, Claudia E., Roche, Ellen T. , Griffiths, Leigh G. , Yuk, Hyunwoo , Chen, Xiaoyu , Sarrafian, Tiffany L , Varela, Claudia E , Whyte, William , Guo, Chuan Fei , Roche, Ellen T , Griffiths, Leigh G , Nabzdyk, Christoph , Zhao, Xuanhe , Chen, Xiaoyu , Nabzdyk, Christoph S. , Zhao, Xuanhe

Mayo Clinic

Science Translational Medicine | June 19, 2024 | Volume: 16 | Issue: 752 | Pages: No page available

10.1126/scitranslmed.ado9003 | PMID 38896601 Get It

Current clinically used electronic implants, including cardiac pacing leads for epicardial monitoring and stimulation of the heart, rely on surgical suturing or direct insertion of electrodes to the heart tissue. These approaches can cause tissue trauma during the implantation and retrieval of the pacing leads, with the potential for bleeding, tissue damage, and device failure. Here, we report a bioadhesive pacing lead that can directly interface with cardiac tissue through physical and covalent interactions to support minimally invasive adhesive implantation and gentle on-demand removal of the device with a detachment solution. We developed 3D-printable bioadhesive materials for customized fabrication of the device by graft-polymerizing polyacrylic acid on hydrophilic polyurethane and mixing with poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) to obtain electrical conductivity. The bioadhesive construct exhibited mechanical properties similar to cardiac tissue and strong tissue adhesion, supporting stable electrical interfacing. Infusion of a detachment solution to cleave physical and covalent cross-links between the adhesive interface and the tissue allowed retrieval of the bioadhesive pacing leads in rat and porcine models without apparent tissue damage. Continuous and reliable cardiac monitoring and pacing of rodent and porcine hearts were demonstrated for 2 weeks with consistent capture threshold and sensing amplitude, in contrast to a commercially available alternative. Pacing and continuous telemetric monitoring were achieved in a porcine model. These findings may offer a promising platform for adhesive bioelectronic devices for cardiac monitoring and treatment.
An off-the-shelf bioadhesive patch for sutureless repair of gastrointestinal defects
Wu, Jingjing , Yuk, Hyunwoo , Sarrafian, Tiffany L. , Griffiths, Leigh G. , Nabzdyk, Christoph S. , Zhao, Xuanhe , Griffiths, Leigh G , Nabzdyk, Christoph , Zhao, Xuanhe , Sarrafian, Tiffany L , Guo, Chuan Fei

Mayo Clinic

Science Translational Medicine | February 2, 2022 | Volume: 14 | Issue: 630 | Pages: No page available

10.1126/scitranslmed.abh2857 | PMID 35108064 Get It

Surgical sealing and repair of injured and resected gastrointestinal (GI) organs are critical requirements for successful treatment and tissue healing. Despite being the standard of care, hand-sewn closure of GI defects using sutures faces limitations and challenges. In this work, we introduce an off-the-shelf bioadhesive GI patch capable of atraumatic, rapid, robust, and sutureless repair of GI defects. The GI patch integrates a nonadhesive top layer and a dry, bioadhesive bottom layer, resulting in a thin, flexible, transparent, and ready-to-use patch with tissue-matching mechanical properties. The rapid, robust, and sutureless sealing capability of the GI patch is systematically characterized using ex vivo porcine GI organ models. In vitro and in vivo rat models are used to evaluate the biocompatibility and degradability of the GI patch in comparison to commercially available tissue adhesives (Coseal and Histoacryl). To validate the GI patch’s efficacy, we demonstrate successful sutureless in vivo sealing and healing of GI defects in rat colon, stomach, and small intestine as well as in porcine colon injury models. The proposed GI patch provides a promising alternative to suture for repair of GI defects and offers potential clinical opportunities for the repair of other organs.
Functional Impact of Diaphragm Muscle Sarcopenia in Fischer 344 Rats
Sarrafian, Tiffany L. , Bhatt, Arjun , Khurram, Obaid U. , Fogarty, Matthew J. , Mantilla, Carlos B. , Sieck, Gary C.

Mayo Clinic

The FASEB Journal | June 21, 2021 | Volume: 32 | Issue: S1 | Pages: No page available

10.1096/fasebj.2018.32.1_supplement.743.1 Get It

The diaphragm muscle (DIAm) is the primary inspiratory muscle responsible for force generation across a range of ventilatory and higher force airway clearance behaviors throughout life. Our laboratory has previously reported DIAm sarcopenia, the age‐related atrophy and weakening of skeletal muscle, in multiple rodent models. Interestingly, in Fischer 344 rats, there is an increase in body mass from 6 to 24 months of age, which is greater in females (~140%) than in males (~110%), suggesting potential sex‐related differences in the manifestation of sarcopenia. Transdiaphragmatic pressure (Pdi) measurements provide information about force generation in vivo across a range of motor behaviors. The purpose of this study was to evaluate if there are sex‐related differences in DIAm sarcopenia, and if such differences translate to a functional impact on Pdi generation. We hypothesized that because of differences in weight gain, DIAm sarcopenia is more pronounced in male vs. female Fischer 344 rats, and that there is a greater impact of sarcopenia on maximum Pdi generated by bilateral phrenic nerve stimulation (Pdi max ). Since Pdi generated across a range of ventilatory motor behaviors only requires <50% Pdi max , we also hypothesize that sarcopenia does not impair Pdi generation during ventilatory behaviors. Compared to 6‐month old rats, DIAm sarcopenia was apparent in ‐ 24‐month old rats of both sexes with a 30% reduction in maximum specific force. There was also a ~20% decrease in the cross‐sectional area of type IIx and/or IIb fibers with age, and this reduction was more pronounced in male rats. Thus, these mixed results do not entirely support our hypothesis of more pronounced DIAm sarcopenia in male rats. However, DIAm sarcopenia was associated with a ~30% decrease in Pdi max that was comparable between male and female rats. Importantly, the Pdi generated during ventilatory behaviors was unaffected by DIAm sarcopenia, even during more forceful ventilatory efforts induced by complete oropharyngeal airway occlusion. Although ventilatory behaviors are preserved with aging, a reduction in Pdi max indicates an impaired ability of the DIAm to generate higher force expulsive airway clearance behaviors necessary for maintaining airway patency. Support or Funding Information NIH R01‐AG044615 and T32‐HL105355 This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .
Impact of aging on diaphragm muscle function in male and female Fischer 344 rats
Khurram, Obaid U. , Fogarty, Matthew J. , Sarrafian, Tiffany L. , Bhatt, Arjun , Mantilla, Carlos B. , Sieck, Gary C. , Khurram, Obaid U , Fogarty, Matthew J

Mayo Clinic

Physiological Reports | July 7, 2018 | Volume: 6 | Issue: 13 | Pages: e13786

10.14814/phy2.13786 | PMID 29981218 Get It