Abstract Background White matter (WM) abnormalities have been implicated in clinically relevant functional decline in multiple system atrophy (MSA). Objective To identify the WM and gray matter (GM) abnormalities in MSA and assess the utility of longitudinal structural and diffusion changes as surrogate markers for tracking disease progression in MSA. Methods Twenty‐seven participants with early MSA [15 with clinically predominant cerebellar (MSA‐C) and 12 with clinically predominant parkinsonian features (MSA‐P)] and 14 controls were enrolled as a part of our prospective, longitudinal study of synucleinopathies. Using structural magnetic resonance imaging (MRI) and diffusion MRI (diffusion tensor and neurite orientation and dispersion density imaging), we analyzed whole and regional brain changes in these participants. We also evaluated temporal imaging trajectories based on up to three annual follow‐up scans and assessed the impact of baseline diagnosis on these imaging biomarkers using mixed‐effect models. Results MSA patients exhibited more widespread WM changes than GM, particularly in the cerebellum and brainstem, with greater severity in MSA‐C. Structural and diffusion measures in the cerebellum WM and brainstem deteriorated with disease progression. Rates of progression of these abnormalities were similar in both MSA subtypes, reflecting increasing overlap of clinical features over time. Conclusion WM abnormalities are core features of MSA disease progression and advance at similar rates in clinical MSA subtypes. Multimodal MRI imaging reveals novel insights into the distribution and pattern of brain abnormalities and their progression in MSA. Selected structural and diffusion measures may be useful for tracking disease progression in MSA clinical trials.
Mapping White Matter Changes to Monitor Disease Progression in Multiple System Atrophy (P5-3.008)
AbstractBackgroundPositron emission tomography (PET) imaging with [18F]flortaucipir allows for in‐vivo visualization of aggregated tau in Alzheimer’s disease (AD). The FDA‐approved label for [18F]flortaucipir PET provides a standardized, clinically applicable definition of tau‐PET positivity by visual interpretation. Here, we studied the concordance between this visual interpretation and quantitative approaches employed in research.MethodWe included 2692 participants (cognitively unimpaired [CU] and impaired [CI, MCI or AD dementia]) from four cohorts (Mayo Clinic Study of Aging and ADRC, ADNI, A4, and A05) with available [18F]flortaucipir PET (mean age: 70.2 y, 50.0% females). Three trained readers assessed each [18F]flortaucipir PET scan according to the FDA‐approved method. Visual reads were compared to an established approach for defining tau‐PET positivity based on SUVR values in a temporal meta‐ROI (Jack, et al. Alzheimers Dement. 2017). Previously defined “lenient” (SUVR = 1.22) and “conservative” (SUVR = 1.30) cut‐points were explored. In addition, visual reads were compared to tau‐PET positivity as defined by a scheme based on the expected spatial progression of tau pathology from the medial temporal lobe (MTL) to the temporal neocortex (NEO) (Ossenkoppele, et al. Nat Med. 2022; cut‐points: SUVRMTL = 1.30, SUVRNEO = 1.37).ResultConcordance between visual and quantitative approaches was limited (Figure 1): the “lenient” and MTL‐NEO methods yielded high rates of quantitative‐positive, visual‐negative scans (73‐52% and 26‐18% for CU and CI, respectively), while the “conservative” cut‐point failed to detect 45% and 13% of the CU and CI visual‐positive scans, respectively. The prevalence of tau‐PET positivity in Aβ‐negative individuals was highest with the “lenient” cut‐point (∼24%) and lowest with visual interpretation (∼3%) (Figure 2). Visual‐positive, quantitative‐negative individuals were more frequently Aβ‐positive than visual‐negative, quantitative‐positive individuals (“lenient”: 86% vs 50%, p<0.001; “conservative”: 87% vs 58%, p<0.001; MTL‐NEO: 85% vs 70%, p = 0.005). Among visually‐positive participants, 164 (28%) showed a tau deposition pattern that deviated from the expected MTL to NEO progression (Figure 3).ConclusionVisual and quantitative methods for [18F]flortaucipir PET are non‐exchangeable. Tau‐PET positivity based on visual interpretation aligns better with Aβ‐pathology. A significant number of visually‐positive participants showed a pattern of tau accumulation that deviated from the expected stereotypical spatial progression and was not detected by standard quantitative methods.
Multi‐channel segmentation allows simultaneous estimation of classic tissue compartments, WMH and enlarged perivascular spaces
AbstractBackgroundLarge neuroimaging studies like ADNI‐4 now include T1‐weighted, T2‐weighted and FLAIR images at isotropic1mm resolution for investigation of both neurodegenerative and cerebrovascular disease. These three input types allow segmentation of GM, WM, DeepGM, WMH, and CSF compartments. Additionally, this supports automated assessment of enlarged perivascular spaces (PVS). Our objective was to propose a unified framework for segmentation of intracranial classes and PVS while reducing human effort.MethodsFLAIR and T2‐weighted images are aligned to the T1‐weighted image.. Standard SPM12 unified segmentation using all three input images establishes deformations between subject and template space and bias field corrections. Extended tissue priors including deep GM are deformed into subject space. Adding mean intensities from high probability deep GM voxels as seeds and using the extended prior set, segmentation is re‐started, refining model parameters, deformations and bias‐field estimates. The procedure repeats, adding a WMH channel, resulting in a segmentation including GM, WM, CSF, deep GM, WMH and nuisance classes. Frangi filters are applied to the T1‐ and T2‐ weighted images. Filter response images are smoothed, averaged, masked and inserted in place of the CSF prior. Probability maps of vessel‐like shapes with CSF‐like contrast are estimated to identify PVS. Visual grading was also performed for comparison.ResultsThe method was applied to 300 participants. Visual quality control found two instances of poor WMH over‐segmentation. Perivascular space maps were all visually reasonable. Standard segmentation classes were visibly superior to single T1‐based segmentation. Figures 1,2 present examples. Pearson correlations of PVS fractional volume with multiple human raters’ PVS counts in CSO/CR was over 0.7 in a subset of 125 participants (Figure 3).ConclusionModern dementia protocols include high‐resolution T1‐weighted, T2‐weighted, and FLAIR images that can be used together as inputs to extend probabilistic segmentation adding deep grey and WMH classes with automated PVS assessment.
Concordance between visual interpretation and quantitative analysis of [18F]flortaucipir pet images
AbstractBackgroundPositron emission tomography (PET) imaging with [18F]flortaucipir allows for in‐vivo visualization of aggregated tau in Alzheimer’s disease (AD). The FDA‐approved label for [18F]flortaucipir PET provides a standardized, clinically applicable definition of tau‐PET positivity by visual interpretation. Here, we studied the concordance between this visual interpretation and quantitative approaches employed in research.MethodWe included 2692 participants (cognitively unimpaired [CU] and impaired [CI, MCI or AD dementia]) from four cohorts (Mayo Clinic Study of Aging and ADRC, ADNI, A4, and A05) with available [18F]flortaucipir PET (mean age: 70.2 y, 50.0% females). Three trained readers assessed each [18F]flortaucipir PET scan according to the FDA‐approved method. Visual reads were compared to an established approach for defining tau‐PET positivity based on SUVR values in a temporal meta‐ROI (Jack, et al. Alzheimers Dement. 2017). Previously defined “lenient” (SUVR = 1.22) and “conservative” (SUVR = 1.30) cut‐points were explored. In addition, visual reads were compared to tau‐PET positivity as defined by a scheme based on the expected spatial progression of tau pathology from the medial temporal lobe (MTL) to the temporal neocortex (NEO) (Ossenkoppele, et al. Nat Med. 2022; cut‐points: SUVRMTL = 1.30, SUVRNEO = 1.37).ResultConcordance between visual and quantitative approaches was limited (Figure 1): the “lenient” and MTL‐NEO methods yielded high rates of quantitative‐positive, visual‐negative scans (73‐52% and 26‐18% for CU and CI, respectively), while the “conservative” cut‐point failed to detect 45% and 13% of the CU and CI visual‐positive scans, respectively. The prevalence of tau‐PET positivity in Aß‐negative individuals was highest with the “lenient” cut‐point (∼24%) and lowest with visual interpretation (∼3%) (Figure 2). Visual‐positive, quantitative‐negative individuals were more frequently Aß‐positive than visual‐negative, quantitative‐positive individuals (“lenient”: 86% vs 50%, p<0.001; “conservative”: 87% vs 58%, p<0.001; MTL‐NEO: 85% vs 70%, p = 0.005). Among visually‐positive participants, 164 (28%) showed a tau deposition pattern that deviated from the expected MTL to NEO progression (Figure 3).ConclusionVisual and quantitative methods for [18F]flortaucipir PET are non‐exchangeable. Tau‐PET positivity based on visual interpretation aligns better with Aß‐pathology. A significant number of visually‐positive participants showed a pattern of tau accumulation that deviated from the expected stereotypical spatial progression and was not detected by standard quantitative methods.
Multi‐channel segmentation allows simultaneous estimation of classic tissue compartments, WMH and enlarged perivascular spaces
AbstractBackgroundLarge neuroimaging studies like ADNI‐4 now include T1‐weighted, T2‐weighted and FLAIR images at isotropic1mm resolution for investigation of both neurodegenerative and cerebrovascular disease. These three input types allow segmentation of GM, WM, DeepGM, WMH, and CSF compartments. Additionally, this supports automated assessment of enlarged perivascular spaces (PVS). Our objective was to propose a unified framework for segmentation of intracranial classes and PVS while reducing human effort.MethodFLAIR and T2‐weighted images are aligned to the T1‐weighted image.. Standard SPM12 unified segmentation using all three input images establishes deformations between subject and template space and bias field corrections. Extended tissue priors including deep GM are deformed into subject space. Adding mean intensities from high probability deep GM voxels as seeds and using the extended prior set, segmentation is re‐started, refining model parameters, deformations and bias‐field estimates. The procedure repeats, adding a WMH channel, resulting in a segmentation including GM, WM, CSF, deep GM, WMH and nuisance classes. Frangi filters are applied to the T1‐ and T2‐ weighted images. Filter response images are smoothed, averaged, masked and inserted in place of the CSF prior. Probability maps of vessel‐like shapes with CSF‐like contrast are estimated to identify PVS. Visual grading was also performed for comparison.ResultThe method was applied to 300 participants. Visual quality control found two instances of poor WMH over‐segmentation. Perivascular space maps were all visually reasonable. Standard segmentation classes were visibly superior to single T1‐based segmentation. Figures 1,2 present examples. Pearson correlations of PVS fractional volume with multiple human raters’ PVS counts in CSO/CR was over 0.7 in a subset of 125 participants (Figure 3).ConclusionModern dementia protocols include high‐resolution T1‐weighted, T2‐weighted, and FLAIR images that can be used together as inputs to extend probabilistic segmentation adding deep grey and WMH classes with automated PVS assessment.
Advancing Tau-PET quantification in Alzheimer's disease with machine learning: introducing THETA, a novel tau summary measure
Abstract Alzheimer's disease (AD) exhibits spatially heterogeneous 3R/4R tau pathology distributions across participants, making it a challenge to quantify extent of tau deposition. Utilizing Tau-PET from three independent cohorts, we trained and validated a machine learning model to identify visually positive Tau-PET scans from regional SUVR values and developed a novel summary measure, THETA, that accounts for heterogeneity in tau deposition. The model for identification of tau positivity achieved a balanced test accuracy of 95% and accuracy of ≥87% on the validation datasets. THETA captured heterogeneity of tau deposition, had better association with clinical measures, and corresponded better with visual assessments in comparison with the temporal meta-region-of-interest Tau-PET quantification methods. Our novel approach aids in identification of positive Tau-PET scans and provides a quantitative summary measure, THETA, that effectively captures the heterogeneous tau deposition seen in AD. The application of THETA for quantifying Tau-PET in AD exhibits great potential.
Association of Polysomnographic Sleep Parameters With Neuroimaging Biomarkers of Cerebrovascular Disease in Older Adults With Sleep Apnea