Citations

Clear

23 citation(s) found for "Song, Pengfei".

Enhancing Row-Column Array (RCA)-Based 3D Ultrasound Vascular Imaging With Spatial-Temporal Similarity Weighting
Zhang, Jingke , Huang, Chengwu , Dong, Zhijie , Liu, Hui , Song, Pengfei , Chen, Shigao , Song, Pengfei , Huang, Chengwu , Zhang, Jingke , Liu, Hui , Lok, U‐Wai , Gong, Ping

Mayo Clinic

IEEE Transactions on Medical Imaging | August 6, 2024 | Volume: 44 | Issue: 1 | Pages: 297-309

10.1109/tmi.2024.3439615 | PMID 39106128 Get It

Real-time 3D ultrasound imaging with a clip-on device attached to common 1D array transducers
Li, Shuangliang , Zou, Jun , Dong, Zhijie , Huang, Chengwu , Lowerison, Matthew R. , Yan, Dongliang, Wang, Yike , Chen, Shigao , Song, Pengfei

Mayo Clinic

The Journal of the Acoustical Society of America | July 3, 2024 | Volume: 155 | Issue: 3_Supplement | Pages: A102-A102

10.1121/10.0026955 Get It

Performing 3D ultrasound imaging at a real-time volume rate (e.g., >20 Hz) is a challenging task. While 2D array transducers remain the most practical approach for real-time 3D imaging, the large number of transducer elements (e.g., several thousand) that are necessary to cover an effective 3D field-of-view impose a fundamental constraint on imaging speed. Although solutions such as multiplexing and specialized transducers, including sparse arrays and row-column-addressing arrays, have been developed to address this limitation, they inevitably compromise imaging quality (e.g., SNR, resolution) in favor of speed. Coupled with the high equipment cost of 2D arrays, these compromises hinder the widespread adoption of 3D ultrasound imaging technologies in clinical settings. In this presentation, we introduce an innovative transducer clip-on device comprising a water-immersible, fast-tilting electromechanical acoustic reflector and a redirecting reflector to enable real-time 3D ultrasound imaging using common 1D array transducers. We will first introduce the principles underlying our novel technique, followed by validation studies incorporating simulation and experimental data. We will also demonstrate the feasibility of using the clip-on device to achieve a high 3D imaging volume rate that is suitable for advanced imaging modes such as shear wave elastography, blood flow imaging, and super-resolution ultrasound localization microscopy.
Three-Dimensional Shear Wave Elastography Using Acoustic Radiation Force and a 2-D Row-Column Addressing (RCA) Array
Dong, Zhijie , Lowerison, Matthew R. , Huang, Chengwu , Chen, Shigao , Song, Pengfei , Lowerison, Matthew , Song, Pengfei , Huang, Chengwu , Lok, U‐Wai

Mayo Clinic

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | February 16, 2024 | Volume: 71 | Issue: 4 | Pages: 448-458

10.1109/tuffc.2024.3366540 | PMID 38363671 Get It

High-Volume-Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors
Dong, Zhijie , Li, Shuangliang , Duan, Xiaoyu , Lowerison, Matthew R. , Huang, Chengwu , You, Qi , Chen, Shigao , Zou, Jun , Song, Pengfei , Lowerison, Matthew , Song, Pengfei , Huang, Chengwu

Mayo Clinic

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control | June 5, 2023 | Volume: 70 | Issue: 8 | Pages: 799-809

10.1109/tuffc.2023.3282949 | PMID 37276113 Get It

Three-Dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array
Lok, U‐Wai , Chen, Shigao , Song, Pengfei , Song, Pengfei , Lok, U-Wai , Dong, Zhijie , Kim, Jihun , Huang, Chengwu , Lowerison, Matthew R.

Mayo Clinic

BME Frontiers | July 19, 2022 | Volume: 2022 | Issue: No issue available | Pages: No page available

10.34133/2022/9879632 | PMID 37850186 Get It

Objective . To develop a 3D shear wave elastography (SWE) technique using a 2D row column addressing (RCA) array, with either external vibration or acoustic radiation force (ARF) as the shear wave source. Impact Statement . The proposed method paves the way for clinical translation of 3D SWE based on the 2D RCA, providing a low-cost and high volume rate solution that is compatible with existing clinical systems. Introduction . SWE is an established ultrasound imaging modality that provides a direct and quantitative assessment of tissue stiffness, which is significant for a wide range of clinical applications including cancer and liver fibrosis. SWE requires high frame rate imaging for robust shear wave tracking. Due to the technical challenges associated with high volume rate imaging in 3D, current SWE techniques are typically confined to 2D. Advancing SWE from 2D to 3D is significant because of the heterogeneous nature of tissue, which demands 3D imaging for accurate and comprehensive evaluation. Methods . A 3D SWE method using a RCA array was developed with a volume rate up to 2000 Hz. The performance of the proposed method was systematically evaluated on tissue-mimicking elasticity phantoms and in an in vivo case study. Results . 3D shear wave motion induced by either external vibration or ARF was successfully detected with the proposed method. Robust 3D shear wave speed maps were reconstructed for phantoms and in vivo . Conclusion . The high volume rate 3D imaging provided by the 2D RCA array provides a robust and practical solution for 3D SWE with a clear pathway for future clinical translation.
Curvelet Transform-Based Sparsity Promoting Algorithm for Fast Ultrasound Localization Microscopy
You, Qi , Trzasko, Joshua D. , Lowerison, Matthew R. , Chen, Xi , Dong, Zhijie , ChandraSekaran, Nathiya Vaithiyalingam, Llano, Daniel A. , Chen, Shigao , Song, Pengfei , Lowerison, Matthew , Song, Pengfei , ChandraSekaran, Nathiya V.

Mayo Clinic

IEEE Transactions on Medical Imaging | March 28, 2022 | Volume: 41 | Issue: 9 | Pages: 2385-2398

10.1109/tmi.2022.3162839 | PMID 35344488 Get It

Super-resolution ultrasound localization microscopy based on a high frame-rate clinical ultrasound scanner: an in-human feasibility study
Huang, Chengwu , Zhang, Wei , Lok, U-Wai, Tang, Shanshan, Yin, Tinghui, Zhang, Xirui , Zhu, Lei, Sang, Maodong, Song, Pengfei, Zheng, Rongqin, Chen, Shigao, Chen, Shigao , Lok, U‐Wai , Yin, Tinghui , Gong, Ping , Zhang, Xirui , Huang, Chengwu , Lok, U-Wai , Zhang, Wei , Tang, Shanshan, Yin, Tinghui, Zhu, Lei, Sang, Maodong, Song, Pengfei, Zheng, Rongqin, Chen, Shigao

Mayo Clinic

Physics in Medicine & Biology | March 16, 2021 | Volume: 66 | Issue: 8 | Pages: 08NT01

10.1088/1361-6560/abef45 | PMID 33725687 Get It

Abstract Non-invasive detection of microvascular alterations in deep tissues in vivo provides critical information for clinical diagnosis and evaluation of a broad-spectrum of pathologies. Recently, the emergence of super-resolution ultrasound localization microscopy (ULM) offers new possibilities for clinical imaging of microvasculature at capillary level. Currently, the clinical utility of ULM on clinical ultrasound scanners is hindered by the technical limitations, such as long data acquisition time, high microbubble (MB) concentration, and compromised tracking performance associated with low imaging frame-rate. Here we present a robust in-human ULM on a high frame-rate (HFR) clinical ultrasound scanner to achieve super-resolution microvessel imaging using a short acquisition time (<10 s). Ultrasound MB data were acquired from different human tissues, including a healthy liver and a diseased liver with acute-on-chronic liver failure, a kidney, a pancreatic tumor, and a breast mass using an HFR clinical scanner. By leveraging the HFR and advanced processing techniques including sub-pixel motion registration, MB signal separation, and Kalman filter-based tracking, MBs can be robustly localized and tracked for ULM under the circumstances of relatively high MB concentration associated with standard clinical MB administration and limited data acquisition time in humans. Subtle morphological and hemodynamic information in microvasculature were shown based on data acquired with single breath-hold and free-hand scanning. Compared with contrast-enhanced power Doppler generated based on the same MB dataset, ULM showed a 5.7-fold resolution improvement in a vessel based on a linear transducer, and provided a wide-range blood flow speed measurement that is Doppler angle-independent. Microvasculatures with complex hemodynamics can be well-differentiated at super-resolution in both normal and pathological tissues. This preliminary study implemented the ultrafast in-human ULM in various human tissues based on a clinical scanner that supports HFR imaging, indicating the potentials of the technique for various clinical applications. However, rigorous validation of the technique in imaging human microvasculature (especially for those tiny vessel structure), preferably with a gold standard, is still required.
Radiological Society of North America/Quantitative Imaging Biomarker Alliance Shear Wave Speed Bias Quantification in Elastic and Viscoelastic Phantoms
Palmeri, Mark L. , Milkowski, Andy , Barr, R. Graham , Carson, Paul L. , Couade, Mathieu , Chen, Shigao , Dhyani, Manish , Ehman, Richard L. , Garra, Brian S. , Gee, Albert, Guenette, Gilles, Hah, Zaegyoo , Lynch, Ted , Macdonald, Michael , Managuli, Ravi , Nightingale, Kathryn R. , Obuchowski, Nancy A. , Rouze, Ned C. , Morris, D. Cody , Fielding, Shana, Chan, Derek Y. , Choudhury, Kingshuk Roy , Yang, Siyun , Shamdasani, Vijay, Wear, Keith A. , Xie, Hua , Qiang, Bo, Rosenzweig, Stephen, Okamura, Yoko, McLaughlin, Glen, Chen, Yuling , Napolitano, David , Carlson, Lindsey , Erpelding, Todd N. , Barr, Richard , Carson, Paul , Dhyani, Manish , Ehman, Richard , Hah, Zaegyoo , Lynch, Ted , Macdonald, Michael , Managuli, Ravi , Miette, Veronique , Nightingale, Kathryn R , Obuchowski, Nancy , Rouze, Ned C , Morris, D Cody , Deng, Yufeng , Chan, Derek , Choudhury, Kingshuk , Samir, Anthony E , Urban, Matthew W , Wear, Keith , Ozturk, Arinc , Song, Pengfei , McAleavey, Stephen , Napolitano, David , Carlson, Lindsey , Hall, Timothy J , Chen, Jun , Miette, Véronique , Urban, Matthew W. , Song, Pengfei , Wang, Michael , Hall, Timothy J.

Mayo Clinic

Journal of Ultrasound in Medicine | January 10, 2021 | Volume: 40 | Issue: 3 | Pages: 569-581

10.1002/jum.15609 | PMID 33410183 Get It

ObjectivesTo quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms.MethodsTwo elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz.ResultsThe SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a − 0.27 ± 0.027‐m/s (−12.2% ± 1.2%) bias when using the clinically implemented 60‐Hz vibration source.ConclusionsShear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140‐Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.
Techniques for Improving Ultrasound Visualization of Biopsy Markers in Axillary Lymph Nodes
Lee, Christine U. , Zhou, Chenyun , Hyde, Brenda , Hangiandreou, Nicholas J., Hangiandreou, Nicholas, Song, Pengfei

Mayo Clinic

Journal of Clinical Imaging Science | April 18, 2020 | Volume: 10 | Issue: No issue available | Pages: 21

10.25259/jcis_9_2020 | PMID 32363083 Get It

Objective: Biopsy markers are often placed into biopsy-proven metastatic axillary lymph nodes to ensure later accurate node excision. Ultrasound is the preferred imaging modality in the axilla. However, sonographic identification of biopsy markers after neoadjuvant therapy can be challenging. This is due to poor conspicuity relative to surrounding parenchymal interfaces, treatment-related alteration of malignant morphology during neoadjuvant chemotherapy, or extrusion of the marker from the target. To the authors’ knowledge, the literature provides no recommendations for ultrasound scanning parameters that improve the detection of biopsy markers. The purpose of this manuscript is 3-fold: (1) To determine scanning parameters that improve sonographic conspicuity of biopsy markers in a phantom and cadaver model; (2) to implement these scanning parameters in the clinical setting; and (3) to provide strategies that might increase the likelihood of successful ultrasound detection of biopsy markers in breast imaging practices. Materials and Methods: An ex vivo study was performed using a phantom designed to simulate the heterogeneity of normal mammary or axillary soft tissues. A selection of available biopsy markers was deployed into this phantom and ultrasound (GE LOGIQ E9) was performed. Scanning parameters were adjusted to optimize marker conspicuity. For the cadaver study, the biopsy markers were deployed using ultrasound guidance into axillary lymph nodes of a female cadaver. Adjustments in transducer frequency, dynamic range, cross-beam (spatial compound imaging), beam steering, speckle reduction imaging, harmonic imaging, colorization, and speed of sound were evaluated. Settings that improved marker detection were used clinically for a year. Results: Sonographic scanning settings that improved biopsy marker conspicuity included increasing transducer frequency, decreasing dynamic range, setting cross-beam to medium hybrid, turning on beam steering, and setting speckle reduction imaging in the mid-range. There was no appreciable improvement with harmonic imaging, colorization, or speed of sound. Conclusion: On a currently available clinical ultrasound scanning system, ultrasound scanning parameters can be adjusted to improve the conspicuity of biopsy markers. Overall, optimization requires a balance between techniques that clinically increase contrast (dynamic range, harmonic imaging, and steering) and those that minimize graininess (spatial compound imaging, speckle reduction imaging, and steering). Additional scanning and procedural strategies have been provided to improve the confidence of sonographic detection of biopsy markers closely associated with the intended target.
Quantitative Inflammation Assessment for Crohn Disease Using Ultrasensitive Ultrasound Microvessel Imaging
Kolbe, Amy B. , Sheedy, Shannon P. , Yu, Yue , Zhou, Chenyun , Lok, U‐Wai , Tang, Shanshan , Bruining, David H. , Knudsen, John M. , Chen, Shigao , Gong, Ping , Ling, Wenwu, Lok, U-Wai , Gong, Ping , Song, Pengfei , Huang, Chengwu , Ling, Wenwu

Mayo Clinic

Journal of Ultrasound in Medicine | April 16, 2020 | Volume: 39 | Issue: 9 | Pages: 1819-1827

10.1002/jum.15290 | PMID 32297357 Get It

ObjectivesCrohn disease (CD) is a chronic inflammation in the digestive tract that affects millions of Americans. Bowel vascularity has important diagnostic information because inflammation is associated with blood flow changes. We recently developed an ultrasensitive ultrasound microvessel imaging (UMI) technique with high vessel sensitivity. This study aimed to evaluate the feasibility of UMI to assist CD detection and staging.MethodsUltrasound microvessel imaging was performed on 76 bowel wall segments from 48 symptomatic patients with CD. Clinically indicated computed tomographic/magnetic resonance enterography was used as the reference standard. The vessel‐length ratio (VLR, the number of vessel pixels in the bowel wall segment normalized to the segment length) was derived in both conventional color flow imaging (CFI) and UMI to quantitatively stage disease activity. Receiver operating characteristic curves were then analyzed between different disease groups.ResultsThe VLR‐CFI and VLR‐UMI detected similar correlations between vascularization and disease activity: severe inflammation had a higher VLR than normal/mildly inflamed bowels (P < .05). No significant difference was found between quiescent and mild CD due to the small sample size. The VLR‐CFI had more difficulties in distinguishing quiescent versus mild CD compared to the VLR‐UMI. After combining the VLR‐UMI with thickness, in the receiver operating characteristic curve analysis, the areas under the curves (AUCs) improved to AUC1 = 0.996 for active versus quiescent CD, AUC2 = 0.978 for quiescent versus mild CD, and AUC3 = 0.931 for mild versus severe CD, respectively, compared to those using thickness alone (AUC1 = 0.968; P = .04; AUC2 = 0.919; P = .16; AUC3 = 0.857; P = .01).ConclusionsUltrasound microvessel imaging offers a safe and cost‐effective tool for CD diagnosis and staging, which may potentially assist disease activity classification and therapy efficacy evaluation.