Background Deep brain stimulation (DBS) has been investigated for patients with drug-resistant epilepsy who are not candidates for resective surgery. Because different types of epilepsy involve distinct brain networks, numerous DBS targets have been explored, yet a comprehensive synthesis is lacking. Methods To provide a comprehensive overview of this expanding literature, we conducted a systematic review of studies for DBS in epilepsy, including case series, prospective and retrospective studies. We collected data on surgical targets, individual disease characteristics, outcomes and precise electrode placements. DBS electrode coordinates were gathered into a common template space and related to clinical outcomes. Results We included 124 studies, corresponding to 1210 patients and 20 distinct surgical targets. While the anterior (ANT) and centromedian (CM) nuclei of the thalamus remain the most studied, we also review less commonly used targets that show promise for specific forms of epilepsy and may warrant further investigation. Substantial variability in targeting strategies and electrode placement was observed within each of the target regions. Importantly, significant relationships between stimulation location and outcomes were identified for ANT-DBS and CM-DBS. For ANT-DBS, shorter distance to the mammillothalamic tract junction was associated with greater seizure reduction on both study-level and patient-level analyses (r=−0.55, p<0.001 and r=−0.51, p<0.001, respectively). For CM-DBS, localisation effects may be dependent on the form of epilepsy, with stimulation of the parvocellular CM being associated with better outcomes in generalised epilepsy. Conclusions Our results emphasise the importance of accurate targeting in DBS for epilepsy. Our database and atlas of DBS targets are made publicly available, potentially serving further meta-analytical work. PROSPERO registration number CRD420250649304.
Comonitoring of adenosine and dopamine using the Wireless Instantaneous Neurotransmitter Concentration System: proof of principle
Object The authors of previous studies have demonstrated that local adenosine efflux may contribute to the therapeutic mechanism of action of thalamic deep brain stimulation (DBS) for essential tremor. Real-time monitoring of the neurochemical output of DBS-targeted regions may thus advance functional neurosurgical procedures by identifying candidate neurotransmitters and neuromodulators involved in the physiological effects of DBS. This would in turn permit the development of a method of chemically guided placement of DBS electrodes in vivo. Designed in compliance with FDA-recognized standards for medical electrical device safety, the authors report on the utility of the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for real-time comonitoring of electrical stimulation–evoked adenosine and dopamine efflux in vivo, utilizing fast-scan cyclic voltammetry (FSCV) at a polyacrylonitrile-based (T-650) carbon fiber microelectrode (CFM). Methods The WINCS was used for FSCV, which consisted of a triangle wave scanned between −0.4 and +1.5 V at a rate of 400 V/second and applied at 10 Hz. All voltages applied to the CFM were with respect to an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single T-650 carbon fiber (r = 2.5 μm) into a glass capillary and pulling to a microscopic tip using a pipette puller. The exposed carbon fiber (the sensing region) extended beyond the glass insulation by ~ 50 μm. Proof of principle tests included in vitro measurements of adenosine and dopamine, as well as in vivo measurements in urethane-anesthetized rats by monitoring adenosine and dopamine efflux in the dorsomedial caudate putamen evoked by high-frequency electrical stimulation of the ventral tegmental area and substantia nigra. Results The WINCS provided reliable, high-fidelity measurements of adenosine efflux. Peak oxidative currents appeared at +1.5 V and at +1.0 V for adenosine, separate from the peak oxidative current at +0.6 V for dopamine. The WINCS detected subsecond adenosine and dopamine efflux in the caudate putamen at an implanted CFM during high-frequency stimulation of the ventral tegmental area and substantia nigra. Both in vitro and in vivo testing demonstrated that WINCS can detect adenosine in the presence of other easily oxidizable neurochemicals such as dopamine comparable to the detection abilities of a conventional hardwired electrochemical system for FSCV. Conclusions Altogether, these results demonstrate that WINCS is well suited for wireless monitoring of high-frequency stimulation-evoked changes in brain extracellular concentrations of adenosine. Clinical applications of selective adenosine measurements may prove important to the future development of DBS technology.