Citations

Clear

2 citation(s) found for "Shi, Chengyu".

AAPM TG report 330: EPID‐based quality assurance of linear accelerators
Sun, Baozhou, Yaddanapudi, Sridhar, Mutic, Sasa, Shi, Chengyu, McCurdy, Boyd M. C., Popple, Richard A., Lu, Minghui, Kim, Taeho, Clark, Jennifer R, Greer, Peter B, Yaddanapudi, Sridhar , Yaddanapudi, Sridhar , Sun, Baozhou, Mutic, Sasa, Shi, Chengyu, McCurdy, Boyd M. C., Popple, Richard A., Lu, Minghui, Kim, Taeho, Clark, Jennifer R, Greer, Peter B.

Mayo Clinic

Medical Physics | September 13, 2025 | Volume: 52 | Issue: 9 | Pages: No page available

10.1002/mp.18114 Get It

Abstract Electronic portal imaging devices (EPIDs) have been in widespread clinical use for almost two decades due to favorable measurement characteristics such as fast image acquisition, high sensitivity and resolution, digital data format, long‐term stability, linear dose response, and large detection area. On‐board EPIDs are widely used as a quality assurance (QA) tool to monitor nearly every aspect of linear accelerator (linac) performance. In both the commercial QA equipment market and in clinical practice, there is a trend toward replacing conventional QA approaches with fully automated, EPID‐based QA tools. Despite widespread use, EPIDs are complex devices, and there has yet to be consensus or formal recommendations published by the AAPM for their use in routine linac QA. Task Group 330 (TG‐330) was, therefore, formed to provide guidelines and recommendations for physicists on the safe and appropriate use of EPIDs for linac QA. In particular, the report: (a) provides a comprehensive review of the characteristics and limitations of EPIDs as time‐resolved measurement devices and dosimeters; (b) summarizes the application of EPIDs for linac QA; (c) provides recommendations on efficient and effective implementations of EPID‐based QA techniques; (d) describes risks associated with the use of EPIDs for linac QA and provides examples of how risk analysis can be used to ensure the safe use of EPIDs for linac QA. Many of the guidelines in this report are drawn from the literature that is included in the references and from the collective experience of the task group members. This report does not provide recommendations on the implementation of EPID‐based patient‐specific IMRT or VMAT QA, which is the topic of AAPM's report from AAPM TG‐307.
Applications of Various Range Shifters for Proton Pencil Beam Scanning Radiotherapy
Lin, Haibo , Chen, Qing , Zhai, Huifang , McDonough, James E., Tochner, Zelig, Both, Stefan , Shi, Chengyu , Huang, Sheng , Shen, Jiajian , Kang, Minglei , Deville, Curtiland , Simone, Charles B.

Mayo Clinic

No container title available | March 10, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-283968/v1 Get It

Abstract Background: A range pull-back device, such as a machine-related range shifter (MRS) or a universal patient-related range shifter (UPRS), is needed in pencil beam scanning technique to treat shallow tumors. Methods: three UPRS made by QFix (Avondale, PA, USA) allow treating targets across the body: U-shaped bolus (UB), anterior lateral bolus (ALB) and couch top bolus (CTB). HN patients who used the UPRS were tested. The in-air spot sizes were measured and compared in this study at snout positions: 15 cm, 25 cm, and 35 cm. A solid water phantom with the ALB placed at 0, 10 and 20 cm air gaps to the phantom surface was also measured using a single-field optimized pencil beam scanning field. The two dimensional dose maps at the middle of the spread-out Bragg peak were measured using ion chamber array MatriXX PT (IBA-Dosimetry, Schwarzenbruck, Germany) located at iso-center and compared with the treatment planning system. Results: A UPRS can be consistently placed close to the patient and maintains a relatively small spot size resulting in improved dose distributions. However, when a UPRS is non-removable (e.g. thick couch top), the quality of volumetric imaging is degraded due to their high Z material construction, hindering the value of Image-Guided Radiation Therapy (IGRT). Limitations of using UPRS with small air gaps include reduced couch weight limit, potential collision with patient or immobilization devices and challenges using non-coplanar fields with certain UPRS. Our experience showed the combination of a U-shaped bolus exclusively for a head-and-neck target and an MRS as complimentary for head-and-neck targets as well as for all other treatment sites may be ideal to preserve the dosimetric advantages of pencil beam scanning proton treatments across the body. Conclusion: We have described how to implement UPRS and MRS for various clinical indications using the PBS technique, and comprehensively reviewed the advantage and disadvantages of URPS and MRS. We recommend the removable UB to be employed for the brain and HN treatments only while an automated MRS is used for all proton beams that require RS but not convenient or feasible to UB.